These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

125 related articles for article (PubMed ID: 11939549)

  • 21. [Preparation of covalently bonded cellulose tris (4-methylbenzoate) derivative chiral stationary phases through a polymerization reaction].
    Qin F; Chen X; Liu Y; Kong L; Zou H
    Se Pu; 2004 Nov; 22(6):569-74. PubMed ID: 15807104
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Photochemically Immobilized 4-Methylbenzoyl Cellulose as a Powerful Chiral Stationary Phase for Enantioselective Chromatography.
    Francotte E; Huynh D; Zhang T
    Molecules; 2016 Dec; 21(12):. PubMed ID: 27999329
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Immobilization of (1S,2R)-(+)-2-amino-1,2-diphenylethanol derivates on aminated silica gel with different linkages as chiral stationary phases and their enantioseparation evaluation by HPLC.
    Yin CQ; He BJ; Li SR; Liu YQ; Bai ZW
    Chirality; 2009 Apr; 21(4):442-8. PubMed ID: 18655165
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Chiral stationary phases based on chitosan bis(methylphenylcarbamate)-(isobutyrylamide) for high-performance liquid chromatography.
    Tang S; Bin Q; Chen W; Bai ZW; Huang SH
    J Chromatogr A; 2016 Apr; 1440():112-122. PubMed ID: 26931425
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Determination of the magnitude and enantioselectivity of ligand binding to rat and rabbit serum albumins using immobilized-protein high performance liquid chromatography stationary phases.
    Massolini G; Aubry AF; McGann A; Wainer IW
    Biochem Pharmacol; 1993 Oct; 46(7):1285-93. PubMed ID: 8216380
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Influence of octanoic acid on the reversible protein binding of ketorolac enantiomers to human serum albumin (HSA): comparative liquid chromatographic studies using a HSA chiral stationary phase.
    Hayball PJ; Holman JW; Nation RL
    J Chromatogr B Biomed Appl; 1994 Dec; 662(1):128-33. PubMed ID: 7894686
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Application of bromoacetate-substituted beta-CD-bonded silica particles as chiral stationary phase for HPLC.
    Thamarai Chelvi SK; Yong EL; Gong Y
    J Sep Sci; 2010 Jan; 33(1):74-8. PubMed ID: 19998375
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Application of cellulose 3,5-dichlorophenylcarbamate covalently immobilized on superficially porous silica for the separation of enantiomers in high-performance liquid chromatography.
    Bezhitashvili L; Bardavelidze A; Mskhiladze A; Gumustas M; Ozkan SA; Volonterio A; Farkas T; Chankvetadze B
    J Chromatogr A; 2018 Oct; 1571():132-139. PubMed ID: 30098733
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Development of tryptophan-modified human serum albumin columns for site-specific studies of drug-protein interactions by high-performance affinity chromatography.
    Chattopadhyay A; Tian T; Kortum L; Hage DS
    J Chromatogr B Biomed Sci Appl; 1998 Sep; 715(1):183-90. PubMed ID: 9792509
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Silica particles encapsulated poly(styrene-divinylbenzene) monolithic stationary phases for micro-high performance liquid chromatography.
    Bakry R; Stöggl WM; Hochleitner EO; Stecher G; Huck CW; Bonn GK
    J Chromatogr A; 2006 Nov; 1132(1-2):183-9. PubMed ID: 16920130
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Influence of vinyl monomers and temperature on immobilization of cellulose 3,5-dimethylphenylcarbamate onto silica gel as chiral stationary phases for high-performance liquid chromatography.
    Chen XM; Yamamoto C; Okamoto Y
    J Chromatogr A; 2006 Feb; 1104(1-2):62-8. PubMed ID: 16359692
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Comparative high-performance liquid chromatography enantioseparations on polysaccharide based chiral stationary phases prepared by coating totally porous and core-shell silica particles.
    Lomsadze K; Jibuti G; Farkas T; Chankvetadze B
    J Chromatogr A; 2012 Apr; 1234():50-5. PubMed ID: 22349144
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Synthesis and evaluation of pseudopeptide chiral stationary phases for enantioselective resolution.
    Shen H; Du G; Liu K; Ye L; Xie S; Jiang L
    J Chromatogr A; 2017 Oct; 1521():53-62. PubMed ID: 28951050
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Liquid crystalline polymers as stationary phases. IV. Chemical bonding and immobilization of the polymer on silica characterization by solid-state nuclear magnetic resonance spectroscopy.
    Gritti F; Terrien I; Menu S; Dufourc EJ; Félix G; Achard MF; Hardouin F
    J Chromatogr A; 2001 Jul; 922(1-2):37-50. PubMed ID: 11486885
    [TBL] [Abstract][Full Text] [Related]  

  • 35. [The effect of temperature on the enantiomeric resolutions on albumin and beta-cyclodextrin chiral stationary phases].
    Zhang Q; Zou HF; Chen XM; Wang HL; Ni JY; Zhang ZZ; Yao PJ
    Se Pu; 2001 Jan; 19(1):9-12. PubMed ID: 12541837
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Synthesis of polymer-type chiral stationary phases and their enantioseparation evaluation by high-performance liquid chromatography.
    Huang SH; Bai ZW; Yin CQ; Li SR; Pan ZQ
    Chirality; 2007 Feb; 19(2):129-40. PubMed ID: 17117402
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Resolution of several racemic 3-hydroxy-1,4-benzodiazepin-2-ones by high-performance liquid chromatography on a chiral silica-bonded stationary phase.
    Oliveros L; Minguillon C; Billaud C
    J Pharm Biomed Anal; 1992; 10(10-12):925-30. PubMed ID: 1363690
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Development and evaluation of N-hydroxysuccinimide-activated silica for immobilizing human serum albumin in liquid chromatography columns.
    Kim HS; Kye YS; Hage DS
    J Chromatogr A; 2004 Sep; 1049(1-2):51-61. PubMed ID: 15499917
    [TBL] [Abstract][Full Text] [Related]  

  • 39. New stationary phases for high-performance liquid chromatography based on poly(methyltetradecylsiloxane) thermally immobilized onto zirconized silica.
    Faria AM; Collins KE; Collins CH
    J Chromatogr A; 2006 Jul; 1122(1-2):114-22. PubMed ID: 16696991
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Preparation and characterization of poly(l-phenylalanine) chiral stationary phases with varying peptide length.
    Ohyama K; Oyamada K; Kishikawa N; Ohba Y; Wada M; Maki T; Nakashima K; Kuroda N
    J Chromatogr A; 2008 Oct; 1208(1-2):242-5. PubMed ID: 18817916
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 7.