258 related articles for article (PubMed ID: 11941444)
1. Coated-wire copper(II)-selective electrode based on phenylglyoxal-alpha-monoxime ionophore.
Firooz AR; Mazloum M; Safari J; Amini MK
Anal Bioanal Chem; 2002 Mar; 372(5-6):718-22. PubMed ID: 11941444
[TBL] [Abstract][Full Text] [Related]
2. A copper ion-selective electrode with high selectivity prepared by sol-gel and coated wire techniques.
Mazloum Ardakani M; Salavati-Niasari M; Khayat Kashani M; Ghoreishi SM
Anal Bioanal Chem; 2004 Mar; 378(6):1659-65. PubMed ID: 15214432
[TBL] [Abstract][Full Text] [Related]
3. Selective electrochemical sensor for copper (II) ion based on chelating ionophores.
Singh AK; Mehtab S; Jain AK
Anal Chim Acta; 2006 Aug; 575(1):25-31. PubMed ID: 17723567
[TBL] [Abstract][Full Text] [Related]
4. Construction of a new Cu2+ coated wire ion selective electrode based on 2-((2-(2-(2-(2-hydroxy-5-methoxybenzylidene amino)phenyl)disufanyl)phenylimino)methyl)-4-methoxyphenol Schiff base.
Shokrollahi A; Abbaspour A; Ghaedi M; Haghighi AN; Kianfar AH; Ranjbar M
Talanta; 2011 Mar; 84(1):34-41. PubMed ID: 21315894
[TBL] [Abstract][Full Text] [Related]
5. Strontium(II)-selective electrode based on a macrocyclic tetraamide.
Singh AK; Saxena P; Mehtab S; Gupta B
Talanta; 2006 Apr; 69(2):521-6. PubMed ID: 18970598
[TBL] [Abstract][Full Text] [Related]
6. Nickel analysis in real samples by Ni2+ selective PVC membrane electrode based on a new Schiff base.
Tomar PK; Chandra S; Malik A; Kumar A
Mater Sci Eng C Mater Biol Appl; 2013 Dec; 33(8):4978-84. PubMed ID: 24094213
[TBL] [Abstract][Full Text] [Related]
7. 8-hydroxyquinoline based neutral tripodal ionophore as a copper (II) selective electrode and the effect of remote substitutents on electrode properties.
Mittal SK; Kumar A; Gupta N; Kaur S; Kumar S
Anal Chim Acta; 2007 Feb; 585(1):161-70. PubMed ID: 17386661
[TBL] [Abstract][Full Text] [Related]
8. Bis(2-hydroxyacetophenone)ethylenediimine as a neutral carrier in a coated-wire membrane electrode for lead(II).
Mazloum Ardakani M; Pourhakak P; Salavati-Niasari M
Anal Sci; 2006 Jun; 22(6):865-70. PubMed ID: 16772687
[TBL] [Abstract][Full Text] [Related]
9. A 15-crown-5-functionalized carbosilane dendrimer as ionophore for ammonium selective electrodes.
Chandra S; Buschbeck R; Lang H
Talanta; 2006 Dec; 70(5):1087-93. PubMed ID: 18970885
[TBL] [Abstract][Full Text] [Related]
10. Novel potentiometric sensor for monitoring beryllium based on naphto-9-crown-3.
Ganjali MR; Daftari A; Faal-Rastegar M; Moghimi A
Anal Sci; 2003 Mar; 19(3):353-6. PubMed ID: 12675338
[TBL] [Abstract][Full Text] [Related]
11. Fabrication of a highly selective cadmium (II) sensor based on 1,13-bis(8-quinolyl)-1,4,7,10,13-pentaoxatridecane as a supramolecular ionophore.
Ghaemi A; Tavakkoli H; Mombeni T
Mater Sci Eng C Mater Biol Appl; 2014 May; 38():186-91. PubMed ID: 24656367
[TBL] [Abstract][Full Text] [Related]
12. A coated wire-type lead(II) ion-selective electrode based on a phosphorylated calix[4]arene derivative.
Yaftian MR; Rayati S; Emadi D; Matt D
Anal Sci; 2006 Aug; 22(8):1075-8. PubMed ID: 16896245
[TBL] [Abstract][Full Text] [Related]
13. Coated wire silver-ion selective electrode based on a N,N'-bis(2-thienylmethylene)-1,2-diaminobenzene.
Zare HR; Salavati-Niassary M; Memarzadeh F; Mazloum M; Nasirizadeh N
Anal Sci; 2004 May; 20(5):815-9. PubMed ID: 15171286
[TBL] [Abstract][Full Text] [Related]
14. Silver(I)-selective electrode based on [Bz2Oxo4(18)dieneS4] tetrathia macrocyclic carrier.
Singh AK; Saxena P
Anal Bioanal Chem; 2006 May; 385(1):90-5. PubMed ID: 16601953
[TBL] [Abstract][Full Text] [Related]
15. PVC membrane potentiometric sensor based on 5-pyridino-2,8-dithia[9](2,9)-1,10-phenanthroline-phane for selective determination of neodymium(III).
Shamsipur M; Hosseini M; Alizadeh K; Mousavi MF; Garau A; Lippolis V; Yari A
Anal Chem; 2005 Jan; 77(1):276-83. PubMed ID: 15623306
[TBL] [Abstract][Full Text] [Related]
16. Synthesis of a new oxime and its application to the construction of a highly selective and sensitive Co(II) PVC-based membrane sensor.
Ganjali MR; Mizani F; Emami M; Darjezini M; Darvich MR; Yousefi M
Anal Sci; 2004 Mar; 20(3):531-5. PubMed ID: 15068300
[TBL] [Abstract][Full Text] [Related]
17. Novel platinum(II) selective membrane electrode based on 1,3-bis(2-cyanobenzene)triazene.
Gholivand MB; Mohammadi M; Khodadadian M; Rofouei MK
Talanta; 2009 May; 78(3):922-8. PubMed ID: 19269451
[TBL] [Abstract][Full Text] [Related]
18. Lead(II) ion-selective electrode based on polyaminoanthraquinone particles with intrinsic conductivity.
Li XG; Ma XL; Huang MR
Talanta; 2009 Apr; 78(2):498-505. PubMed ID: 19203615
[TBL] [Abstract][Full Text] [Related]
19. Highly selective and sensitive copper membrane electrode based on a new synthesized Schiff base.
Gholivand MB; Rahimi-Nasrabadi M; Ganjali MR; Salavati-Niasari M
Talanta; 2007 Sep; 73(3):553-60. PubMed ID: 19073070
[TBL] [Abstract][Full Text] [Related]
20. Determination of thiocyanate ions at nanolevel in real samples using coated graphite electrode based on synthesised macrocyclic Zn(II) complex.
Singh P; Singh AK
Anal Bioanal Chem; 2011 Jun; 400(7):2261-9. PubMed ID: 21475945
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]