142 related articles for article (PubMed ID: 11950044)
1. Passivation of nitinol wire for vascular implants--a demonstration of the benefits.
O'Brien B; Carroll WM; Kelly MJ
Biomaterials; 2002 Apr; 23(8):1739-48. PubMed ID: 11950044
[TBL] [Abstract][Full Text] [Related]
2. The role of surface oxide thickness and structure on the corrosion and nickel elution behavior of nitinol biomedical implants.
Rosenbloom SN; Kumar P; Lasley C
J Biomed Mater Res B Appl Biomater; 2021 Sep; 109(9):1334-1343. PubMed ID: 33410251
[TBL] [Abstract][Full Text] [Related]
3. Surface characteristics, corrosion and bioactivity of chemically treated biomedical grade NiTi alloy.
Chembath M; Balaraju JN; Sujata M
Mater Sci Eng C Mater Biol Appl; 2015 Nov; 56():417-25. PubMed ID: 26249609
[TBL] [Abstract][Full Text] [Related]
4. Effect of surface treatment of NiTi alloy on its corrosion behavior in Hanks' solution.
Cissé O; Savadogo O; Wu M; Yahia L
J Biomed Mater Res; 2002 Sep; 61(3):339-45. PubMed ID: 12115458
[TBL] [Abstract][Full Text] [Related]
5. The intrinsically high pitting corrosion resistance of mechanically polished nitinol in simulated physiological solutions.
Bai Z; Rotermund HH
J Biomed Mater Res B Appl Biomater; 2011 Oct; 99(1):1-13. PubMed ID: 21648066
[TBL] [Abstract][Full Text] [Related]
6. Corrosion resistance of a Nitinol ocular microstent: Implications on biocompatibility.
Nagaraja S; Pelton AR
J Biomed Mater Res B Appl Biomater; 2020 Aug; 108(6):2681-2690. PubMed ID: 32159908
[TBL] [Abstract][Full Text] [Related]
7. Evolution of the passive film on mechanically damaged nitinol.
Schroeder V
J Biomed Mater Res A; 2009 Jul; 90(1):1-17. PubMed ID: 18481784
[TBL] [Abstract][Full Text] [Related]
8. Susceptibility of nitinol to localized corrosion.
Pound BG
J Biomed Mater Res A; 2006 Apr; 77(1):185-91. PubMed ID: 16392125
[TBL] [Abstract][Full Text] [Related]
9. The influence of surface oxides on the distribution and release of nickel from Nitinol wires.
Shabalovskaya SA; Tian H; Anderegg JW; Schryvers DU; Carroll WU; Van Humbeeck J
Biomaterials; 2009 Feb; 30(4):468-77. PubMed ID: 18996586
[TBL] [Abstract][Full Text] [Related]
10. Biocorrosion investigation of two shape memory nickel based alloys: Ni-Mn-Ga and thin film NiTi.
Stepan LL; Levi DS; Gans E; Mohanchandra KP; Ujihara M; Carman GP
J Biomed Mater Res A; 2007 Sep; 82(3):768-76. PubMed ID: 17330873
[TBL] [Abstract][Full Text] [Related]
11. Corrosion behavior of nitinol wires in body fluid environments.
Carroll WM; Kelly MJ
J Biomed Mater Res A; 2003 Dec; 67(4):1123-30. PubMed ID: 14624497
[TBL] [Abstract][Full Text] [Related]
12. Effect of Nitinol surface treatments on its physico-chemical properties.
Pérez LM; Gracia-Villa L; Puértolas JA; Arruebo M; Irusta S; Santamaría J
J Biomed Mater Res B Appl Biomater; 2009 Oct; 91(1):337-47. PubMed ID: 19484775
[TBL] [Abstract][Full Text] [Related]
13. Effect of laser polishing on the surface roughness and corrosion resistance of Nitinol stents.
Park CH; Tijing LD; Pant HR; Kim CS
Biomed Mater Eng; 2015; 25(1):67-75. PubMed ID: 25585981
[TBL] [Abstract][Full Text] [Related]
14. Surface characterizations and corrosion resistance of nickel-titanium orthodontic archwires in artificial saliva of various degrees of acidity.
Huang HH
J Biomed Mater Res A; 2005 Sep; 74(4):629-39. PubMed ID: 16025472
[TBL] [Abstract][Full Text] [Related]
15. An investigation into the effects of polishing on surface hardness and corrosion of orthodontic archwires.
Hunt NP; Cunningham SJ; Golden CG; Sheriff M
Angle Orthod; 1999 Oct; 69(5):433-40. PubMed ID: 10515141
[TBL] [Abstract][Full Text] [Related]
16. Surface, corrosion and biocompatibility aspects of Nitinol as an implant material.
Shabalovskaya SA
Biomed Mater Eng; 2002; 12(1):69-109. PubMed ID: 11847410
[TBL] [Abstract][Full Text] [Related]
17. Influence of Nitinol wire surface treatment on oxide thickness and composition and its subsequent effect on corrosion resistance and nickel ion release.
Clarke B; Carroll W; Rochev Y; Hynes M; Bradley D; Plumley D
J Biomed Mater Res A; 2006 Oct; 79(1):61-70. PubMed ID: 16758455
[TBL] [Abstract][Full Text] [Related]
18. Corrosion resistance, surface mechanical properties, and cytocompatibility of plasma immersion ion implantation-treated nickel-titanium shape memory alloys.
Yeung KW; Poon RW; Liu XY; Ho JP; Chung CY; Chu PK; Lu WW; Chan D; Cheung KM
J Biomed Mater Res A; 2005 Nov; 75(2):256-67. PubMed ID: 16078209
[TBL] [Abstract][Full Text] [Related]
19. Surface mechanical properties, corrosion resistance, and cytocompatibility of nitrogen plasma-implanted nickel-titanium alloys: a comparative study with commonly used medical grade materials.
Yeung KW; Poon RW; Chu PK; Chung CY; Liu XY; Lu WW; Chan D; Chan SC; Luk KD; Cheung KM
J Biomed Mater Res A; 2007 Aug; 82(2):403-14. PubMed ID: 17295246
[TBL] [Abstract][Full Text] [Related]
20. Effect of chemical etching and aging in boiling water on the corrosion resistance of Nitinol wires with black oxide resulting from manufacturing process.
Shabalovskaya S; Rondelli G; Anderegg J; Simpson B; Budko S
J Biomed Mater Res B Appl Biomater; 2003 Jul; 66(1):331-40. PubMed ID: 12808592
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]