These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

181 related articles for article (PubMed ID: 11950047)

  • 1. Micro X-ray diffraction study of superelastic nickel-titanium orthodontic wires at different temperatures and stresses.
    Iijima M; Ohno H; Kawashima I; Endo K; Brantley WA; Mizoguchi I
    Biomaterials; 2002 Apr; 23(8):1769-74. PubMed ID: 11950047
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Mechanical behavior at different temperatures and stresses for superelastic nickel-titanium orthodontic wires having different transformation temperatures.
    Iijima M; Ohno H; Kawashima I; Endo K; Mizoguchi I
    Dent Mater; 2002 Jan; 18(1):88-93. PubMed ID: 11740969
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Differential scanning calorimetry (DSC) analyses of superelastic and nonsuperelastic nickel-titanium orthodontic wires.
    Bradley TG; Brantley WA; Culbertson BM
    Am J Orthod Dentofacial Orthop; 1996 Jun; 109(6):589-97. PubMed ID: 8659468
    [TBL] [Abstract][Full Text] [Related]  

  • 4. X-ray diffraction of nitinol orthodontic arch wires.
    Thayer TA; Bagby MD; Moore RN; DeAngelis RJ
    Am J Orthod Dentofacial Orthop; 1995 Jun; 107(6):604-12. PubMed ID: 7771365
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Influence of stress and phase on corrosion of a superelastic nickel-titanium orthodontic wire.
    Segal N; Hell J; Berzins DW
    Am J Orthod Dentofacial Orthop; 2009 Jun; 135(6):764-70. PubMed ID: 19524836
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Phase transformation analysis of varied nickel-titanium orthodontic wires.
    Ren CC; Bai YX; Wang HM; Zheng YF; Li S
    Chin Med J (Engl); 2008 Oct; 121(20):2060-4. PubMed ID: 19080276
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Bending properties of superelastic and nonsuperelastic nickel-titanium orthodontic wires.
    Khier SE; Brantley WA; Fournelle RA
    Am J Orthod Dentofacial Orthop; 1991 Apr; 99(4):310-8. PubMed ID: 2008890
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Corrosion behavior of shape memory, superelastic, and nonsuperelastic nickel-titanium-based orthodontic wires at various temperatures.
    Pun DK; Berzins DW
    Dent Mater; 2008 Feb; 24(2):221-7. PubMed ID: 17624421
    [TBL] [Abstract][Full Text] [Related]  

  • 9. The effect of short-term temperature changes on superelastic nickel-titanium archwires activated in orthodontic bending.
    Meling TR; Odegaard J
    Am J Orthod Dentofacial Orthop; 2001 Mar; 119(3):263-73. PubMed ID: 11244421
    [TBL] [Abstract][Full Text] [Related]  

  • 10. X-ray diffraction study of low-temperature phase transformations in nickel-titanium orthodontic wires.
    Iijima M; Brantley WA; Guo WH; Clark WA; Yuasa T; Mizoguchi I
    Dent Mater; 2008 Nov; 24(11):1454-60. PubMed ID: 18452984
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Micro-X-ray diffraction observation of nickel-titanium orthodontic wires in simulated oral environment.
    Iijima M; Brantley WA; Kawashima I; Ohno H; Guo W; Yonekura Y; Mizoguchi I
    Biomaterials; 2004 Jan; 25(1):171-6. PubMed ID: 14580920
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Micro-XRD and temperature-modulated DSC investigation of nickel-titanium rotary endodontic instruments.
    Alapati SB; Brantley WA; Iijima M; Schricker SR; Nusstein JM; Li UM; Svec TA
    Dent Mater; 2009 Oct; 25(10):1221-9. PubMed ID: 19524288
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Interlot variations of transition temperature range and force delivery in copper-nickel-titanium orthodontic wires.
    Pompei-Reynolds RC; Kanavakis G
    Am J Orthod Dentofacial Orthop; 2014 Aug; 146(2):215-26. PubMed ID: 25085305
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Stiffness and frictional resistance of a superelastic nickel-titanium orthodontic wire with low-stress hysteresis.
    Liaw YC; Su YY; Lai YL; Lee SY
    Am J Orthod Dentofacial Orthop; 2007 May; 131(5):578.e12-8. PubMed ID: 17482074
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Phase transformation changes in thermocycled nickel-titanium orthodontic wires.
    Berzins DW; Roberts HW
    Dent Mater; 2010 Jul; 26(7):666-74. PubMed ID: 20371115
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Temperature-modulated DSC provides new insight about nickel-titanium wire transformations.
    Brantley WA; Iijima M; Grentzer TH
    Am J Orthod Dentofacial Orthop; 2003 Oct; 124(4):387-94. PubMed ID: 14560268
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Elastic properties of alternative versus single-stranded leveling archwires.
    Rucker BK; Kusy RP
    Am J Orthod Dentofacial Orthop; 2002 Nov; 122(5):528-41. PubMed ID: 12439482
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Force delivery of NiTi orthodontic arch wire at different magnitude of deflections and temperatures: A finite element study.
    Razali MF; Mahmud AS; Mokhtar N
    J Mech Behav Biomed Mater; 2018 Jan; 77():234-241. PubMed ID: 28954242
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Microstructural studies of 35 degrees C copper Ni-Ti orthodontic wire and TEM confirmation of low-temperature martensite transformation.
    Brantley WA; Guo W; Clark WA; Iijima M
    Dent Mater; 2008 Feb; 24(2):204-10. PubMed ID: 17561249
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Mechanical properties of controlled memory and superelastic nickel-titanium wires used in the manufacture of rotary endodontic instruments.
    Zhou HM; Shen Y; Zheng W; Li L; Zheng YF; Haapasalo M
    J Endod; 2012 Nov; 38(11):1535-40. PubMed ID: 23063231
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 10.