These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

150 related articles for article (PubMed ID: 11958404)

  • 1. Accuracy of mechanical torque-limiting devices for implants.
    Standlee JP; Caputo AA; Chwu MY; Sun TT
    Int J Oral Maxillofac Implants; 2002; 17(2):220-4. PubMed ID: 11958404
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Accuracy of an electric torque-limiting device for implants.
    Standlee JP; Caputo AA
    Int J Oral Maxillofac Implants; 1999; 14(2):278-81. PubMed ID: 10212546
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Accuracy of friction-style and spring-style mechanical torque limiting devices for dental implants.
    Vallee MC; Conrad HJ; Basu S; Seong WJ
    J Prosthet Dent; 2008 Aug; 100(2):86-92. PubMed ID: 18672124
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Accuracy of mechanical torque devices for implants used in Brazilian dental offices.
    Santos GC; Passos SP; Coelho Santos MJ
    Int J Prosthodont; 2011; 24(1):38-9. PubMed ID: 21210000
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Critical bending moment of implant-abutment screw joint interfaces: effect of torque levels and implant diameter.
    Tan BF; Tan KB; Nicholls JI
    Int J Oral Maxillofac Implants; 2004; 19(5):648-58. PubMed ID: 15508980
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Accuracy of a manual torque application device for morse-taper implants: a technical note.
    Cehreli MC; Akça K; Tönük E
    Int J Oral Maxillofac Implants; 2004; 19(5):743-8. PubMed ID: 15508992
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Removal torques of conical, tapered implant abutments: the effects of anodization and reduction of surface area.
    Squier RS; Psoter WJ; Taylor TD
    Int J Oral Maxillofac Implants; 2002; 17(1):24-7. PubMed ID: 11858571
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Probabilistic analysis of preload in the abutment screw of a dental implant complex.
    Guda T; Ross TA; Lang LA; Millwater HR
    J Prosthet Dent; 2008 Sep; 100(3):183-93. PubMed ID: 18762030
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Preload loss in gold prosthesis-retaining screws as a function of time.
    Cantwell A; Hobkirk JA
    Int J Oral Maxillofac Implants; 2004; 19(1):124-32. PubMed ID: 14982365
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Variability of mechanical torque-limiting devices in clinical service at a US dental school.
    McCracken MS; Mitchell L; Hegde R; Mavalli MD
    J Prosthodont; 2010 Jan; 19(1):20-4. PubMed ID: 19765196
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Accuracy of electronic implant torque controllers following time in clinical service.
    Mitrani R; Nicholls JI; Phillips KM; Ma T
    Int J Oral Maxillofac Implants; 2001; 16(3):394-9. PubMed ID: 11432659
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Dynamic fatigue resistance of implant-abutment junction in an internally notched morse-taper oral implant: influence of abutment design.
    Cehreli MC; Akça K; Iplikçioğlu H; Sahin S
    Clin Oral Implants Res; 2004 Aug; 15(4):459-65. PubMed ID: 15248881
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Mechanical behavior and failure analysis of prosthetic retaining screws after long-term use in vivo. Part 3: Preload and tensile fracture load testing.
    Al Jabbari YS; Fournelle R; Ziebert G; Toth J; Iacopino AM
    J Prosthodont; 2008 Apr; 17(3):192-200. PubMed ID: 18205737
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Torque generated by handheld screwdrivers and mechanical torquing devices for osseointegrated implants.
    Goheen KL; Vermilyea SG; Vossoughi J; Agar JR
    Int J Oral Maxillofac Implants; 1994; 9(2):149-55. PubMed ID: 8206549
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Removal torque of immediately loaded transitional endosseous implants in human subjects.
    Simon H; Caputo AA
    Int J Oral Maxillofac Implants; 2002; 17(6):839-45. PubMed ID: 12507244
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Evaluation of the ITI Morse taper implant/abutment design with an internal modification.
    Ding TA; Woody RD; Higginbottom FL; Miller BH
    Int J Oral Maxillofac Implants; 2003; 18(6):865-72. PubMed ID: 14696662
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Load fatigue performance of implant-ceramic abutment combinations.
    Nguyen HQ; Tan KB; Nicholls JI
    Int J Oral Maxillofac Implants; 2009; 24(4):636-46. PubMed ID: 19885403
    [TBL] [Abstract][Full Text] [Related]  

  • 18. An in vitro analysis of implant screw torque loss with external hex and internal connection implant systems.
    Piermatti J; Yousef H; Luke A; Mahevich R; Weiner S
    Implant Dent; 2006 Dec; 15(4):427-35. PubMed ID: 17172962
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Axial displacement of abutments into implants and implant replicas, with the tapered cone-screw internal connection, as a function of tightening torque.
    Dailey B; Jordan L; Blind O; Tavernier B
    Int J Oral Maxillofac Implants; 2009; 24(2):251-6. PubMed ID: 19492640
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Maximum dislodging forces of implant overdenture stud attachments.
    Petropoulos VC; Smith W
    Int J Oral Maxillofac Implants; 2002; 17(4):526-35. PubMed ID: 12182295
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.