These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

190 related articles for article (PubMed ID: 11958810)

  • 1. Dilute prothrombin time-based lupus ratio test. Integrated LA testing with recombinant tissue thromboplastin.
    Liestøl S; Jacobsen EM; Wisløff F
    Thromb Res; 2002 Jan; 105(2):177-82. PubMed ID: 11958810
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Paired APTTs of low and high lupus anticoagulant sensitivity permit distinction from other abnormalities and achieve good lupus anticoagulant detection rates in conjunction with dRVVT.
    Kumano O; Amiral J; Dunois C; Peyrafitte M; Moore GW
    Int J Lab Hematol; 2019 Feb; 41(1):60-68. PubMed ID: 30248243
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Laboratory diagnosis of lupus anticoagulants for patients on oral anticoagulant treatment. Performance of dilute Russell viper venom test and silica clotting time in comparison with Staclot LA.
    Tripodi A; Chantarangkul V; Clerici M; Mannucci PM
    Thromb Haemost; 2002 Oct; 88(4):583-6. PubMed ID: 12362227
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Coagulation tests and anti-phospholipid antibodies in patients positive for lupus anticoagulant.
    Sakakura M; Wada H; Watanabe R; Mamamuro M; Okugawa Y; Nakasaki T; Nakase T; Wakita Y; Minamikawa K; Mori Y; Nshikawa M; Shiku H
    Clin Appl Thromb Hemost; 2000 Jul; 6(3):144-50. PubMed ID: 10898274
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Lupus Anticoagulant Testing: Dilute Prothrombin Time (dPT).
    Moore GW
    Methods Mol Biol; 2023; 2663():275-288. PubMed ID: 37204717
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Optimization of the dilute prothrombin time for the detection of the lupus anticoagulant by use of a recombinant tissue thromboplastin.
    Arnout J; Vanrusselt M; Huybrechts E; Vermylen J
    Br J Haematol; 1994 May; 87(1):94-9. PubMed ID: 7947261
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Comparison of six dilute russell viper venom time lupus anticoagulant screen/confirm assay kits.
    McGlasson DL; Fritsma GA
    Semin Thromb Hemost; 2013 Apr; 39(3):315-9. PubMed ID: 23468380
    [TBL] [Abstract][Full Text] [Related]  

  • 8. A quantitative, semi-automated and computer-assisted test for lupus anticoagulant.
    Schjetlein R; Sletnes KE; Wisløff F
    Thromb Res; 1993 Jan; 69(2):239-50. PubMed ID: 8446953
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Mixing test specific cut-off is more sensitive at detecting lupus anticoagulants than index of circulating anticoagulant.
    Moore GW; Culhane AP; Daw CR; Noronha CP; Kumano O
    Thromb Res; 2016 Mar; 139():98-101. PubMed ID: 26916303
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Lupus anticoagulant testing in Europe: an analysis of results from the first European Concerted Action on Thrombophilia (ECAT) survey using plasmas spiked with monoclonal antibodies against human beta2-glycoprotein I.
    Arnout J; Meijer P; Vermylen J
    Thromb Haemost; 1999 Jun; 81(6):929-34. PubMed ID: 10404770
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Sensitivity of the activated partial thromboplastin time, the dilute Russell's viper venom time, and the kaolin clotting time for the detection of the lupus anticoagulant: a direct comparison using plasma dilutions.
    Martin BA; Branch DW; Rodgers GM
    Blood Coagul Fibrinolysis; 1996 Jan; 7(1):31-8. PubMed ID: 8845460
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Comparison between a one-point dilute phospholipid APTT and the dilute Russell viper venom time for verification of lupus anticoagulants.
    Alving BM; Barr CF; Johansen LE; Tang DB
    Thromb Haemost; 1992 Jun; 67(6):672-8. PubMed ID: 1509408
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Practical Considerations and Testing Nuances for the Detection of Lupus Anticoagulant: Do Low Phospholipid Screen Results, Assay Type, and Test Ratio Matter?
    Asakrah S; Davis R; Bhargava P
    Am J Clin Pathol; 2021 Nov; 156(6):1073-1082. PubMed ID: 34075395
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Clinical importance of positive test results for lupus anticoagulant and anticardiolipin antibodies.
    Proven A; Bartlett RP; Moder KG; Chang-Miller A; Cardel LK; Heit JA; Homburger HA; Petterson TM; Christianson TJ; Nichols WL
    Mayo Clin Proc; 2004 Apr; 79(4):467-75. PubMed ID: 15065611
    [TBL] [Abstract][Full Text] [Related]  

  • 15. A two-step coagulation test to identify antibeta-glycoprotein I lupus anticoagulants.
    Pengo V; Biasiolo A; Pegoraro C; Iliceto S
    J Thromb Haemost; 2004 May; 2(5):702-7. PubMed ID: 15099274
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Choice of standard plasma for diagnosis and quantitation of lupus anticoagulants.
    Schjetlein R; Wisløff F
    Thromb Res; 1993 Nov; 72(4):287-94. PubMed ID: 8303668
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Application of different lupus anticoagulant diagnostic algorithms to the same assay data leads to interpretive discrepancies in some samples.
    Moore GW; Maloney JC; de Jager N; Dunsmore CL; Gorman DK; Polgrean RF; Bertolaccini ML
    Res Pract Thromb Haemost; 2017 Jul; 1(1):62-68. PubMed ID: 30046675
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Laboratory identification of lupus anticoagulants using the combination of activated partial thromboplastin time and Russell's viper venom at two phospholipid concentrations.
    Akkawat B; Chantarangkul V; Rojnuckarin P; Juntiang J
    J Med Assoc Thai; 2003 Jun; 86 Suppl 2():S451-8. PubMed ID: 12930024
    [TBL] [Abstract][Full Text] [Related]  

  • 19. [Evaluation of sensitivity and specificity of confirmatory assays for lupus anticoagulant (LA) detection].
    Imoto K; Yasumuro Y; Taki M; Suzuki Y; Akatu S; Tajima C; Ichikawa Y
    Rinsho Byori; 1996 Aug; 44(8):797-801. PubMed ID: 8816068
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Presence of direct thrombin inhibitors can affect the results and interpretation of lupus anticoagulant testing.
    Genzen JR; Miller JL
    Am J Clin Pathol; 2005 Oct; 124(4):586-93. PubMed ID: 16146819
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 10.