These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
126 related articles for article (PubMed ID: 11960661)
1. [Portable ultrasonographic device and bladder dysfunction management in stroke patients]. Granier P; Audry P; Coste B; Fleys E; Trives M; Szczot A Ann Readapt Med Phys; 2002 Apr; 45(4):166-72. PubMed ID: 11960661 [TBL] [Abstract][Full Text] [Related]
2. The utility of a bladder scan protocol using a portable ultrasonographic device in subacute stroke patients. Kim HJ; Chun MH; Han EY; Yi JH; Kim DK Disabil Rehabil; 2012; 34(6):486-90. PubMed ID: 22087731 [TBL] [Abstract][Full Text] [Related]
3. Diagnosis of Postoperative Urinary Retention Using a Simplified Ultrasound Bladder Measurement. Daurat A; Choquet O; Bringuier S; Charbit J; Egan M; Capdevila X Anesth Analg; 2015 May; 120(5):1033-1038. PubMed ID: 25642660 [TBL] [Abstract][Full Text] [Related]
4. Reliability of an automatic ultrasound system in the post partum period in measuring urinary retention. Van Os AF; Van der Linden PJ Acta Obstet Gynecol Scand; 2006; 85(5):604-7. PubMed ID: 16752241 [TBL] [Abstract][Full Text] [Related]
5. Accuracy of Post-Void Residual Urine Volume Measurement Using an Ultrasound Bladder Scanner among Postoperative Radical Hysterectomy Patients. Thanagumtorn K J Med Assoc Thai; 2016 Oct; 99(10):1061-6. PubMed ID: 29952185 [TBL] [Abstract][Full Text] [Related]
6. Accuracy and precision of a new portable ultrasound scanner, the BME-150A, in residual urine volume measurement: a comparison with the BladderScan BVI 3000. Choe JH; Lee JY; Lee KS Int Urogynecol J Pelvic Floor Dysfunct; 2007 Jun; 18(6):641-4. PubMed ID: 17115233 [TBL] [Abstract][Full Text] [Related]
7. [Care for patients with acute stroke: effectiveness of portable vesical ultrasound imaging in the stroke unit]. Rodrigo-Gil J; Suñer-Soler R; Cruz-Díaz V; Bagot-Prats M; Algans-Coll L; Cepeda-Bautista M; Ribó-Regas M; Serena J Rev Neurol; 2012 Feb; 54(3):151-8. PubMed ID: 22278891 [TBL] [Abstract][Full Text] [Related]
8. Application of portable ultrasound scanners in the measurement of post-void residual urine. Teng CH; Huang YH; Kuo BJ; Bih LI J Nurs Res; 2005 Sep; 13(3):216-24. PubMed ID: 16237633 [TBL] [Abstract][Full Text] [Related]
9. Non-invasive bladder volume measurement for the prevention of postoperative urinary retention: validation of two ultrasound devices in a clinical setting. Brouwer TA; van den Boogaard C; van Roon EN; Kalkman CJ; Veeger N J Clin Monit Comput; 2018 Dec; 32(6):1117-1126. PubMed ID: 29516310 [TBL] [Abstract][Full Text] [Related]
10. Incidence and outcome of poststroke urinary retention: a prospective study. Kong KH; Young S Arch Phys Med Rehabil; 2000 Nov; 81(11):1464-7. PubMed ID: 11083349 [TBL] [Abstract][Full Text] [Related]
11. Measurement of residual urine volume using a portable ultrasound instrument. Fuse H; Yokoyama T; Muraishi Y; Katayama T Int Urol Nephrol; 1996; 28(5):633-7. PubMed ID: 9061421 [TBL] [Abstract][Full Text] [Related]
12. Implementation of a standardized voiding management protocol to reduce unnecessary re-catheterization - A quality improvement project. Brackmann M; Carballo E; Uppal S; Torski J; Reynolds RK; McLean K Gynecol Oncol; 2020 May; 157(2):487-493. PubMed ID: 32033800 [TBL] [Abstract][Full Text] [Related]
13. Measurement of bladder volume following cesarean section using bladderscan. Barrington JW; Edwards G; Ashcroft M; Adekanmi O Int Urogynecol J Pelvic Floor Dysfunct; 2001; 12(6):373-4. PubMed ID: 11795639 [TBL] [Abstract][Full Text] [Related]
14. Prevalence of postoperative bladder distension and urinary retention detected by ultrasound measurement. Lamonerie L; Marret E; Deleuze A; Lembert N; Dupont M; Bonnet F Br J Anaesth; 2004 Apr; 92(4):544-6. PubMed ID: 14977795 [TBL] [Abstract][Full Text] [Related]
15. Relation of postvoid residual to urinary tract infection during stroke rehabilitation. Dromerick AW; Edwards DF Arch Phys Med Rehabil; 2003 Sep; 84(9):1369-72. PubMed ID: 13680576 [TBL] [Abstract][Full Text] [Related]
16. Management of temporary urinary retention after arthroscopic knee surgery in low-dose spinal anesthesia: development of a simple algorithm. Luger TJ; Garoscio I; Rehder P; Oberladstätter J; Voelckel W Arch Orthop Trauma Surg; 2008 Jun; 128(6):607-12. PubMed ID: 17968566 [TBL] [Abstract][Full Text] [Related]
17. Clinical utility of a portable ultrasound scanner in the measurement of residual urine volume. Ding YY; Sahadevan S; Pang WS; Choo PW Singapore Med J; 1996 Aug; 37(4):365-8. PubMed ID: 8993133 [TBL] [Abstract][Full Text] [Related]
18. Incidence of postoperative urinary retention (POUR) after joint arthroplasty and management using ultrasound-guided bladder catheterization. Balderi T; Mistraletti G; D'Angelo E; Carli F Minerva Anestesiol; 2011 Nov; 77(11):1050-7. PubMed ID: 21597444 [TBL] [Abstract][Full Text] [Related]
19. Effects of electroacupuncture on recent stroke inpatients with incomplete bladder emptying: a preliminary study. Yu KW; Lin CL; Hung CC; Chou EC; Hsieh YL; Li TM; Chou LW Clin Interv Aging; 2012; 7():469-74. PubMed ID: 23152677 [TBL] [Abstract][Full Text] [Related]
20. Validation of an ultrasound scanner for determing urinary volumes in surgical patients and volunteers. Brouwer TA; Eindhoven BG; Epema AH; Henning RH J Clin Monit Comput; 1999 Aug; 15(6):379-85. PubMed ID: 12578033 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]