BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

151 related articles for article (PubMed ID: 11962763)

  • 1. Counting particles in tissue sections: choices of methods and importance of calibration to minimize biases.
    von Bartheld C
    Histol Histopathol; 2002 Apr; 17(2):639-48. PubMed ID: 11962763
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Analysis of cell death in the trochlear nucleus of the chick embryo: calibration of the optical disector counting method reveals systematic bias.
    Hatton WJ; von Bartheld CS
    J Comp Neurol; 1999 Jun; 409(2):169-86. PubMed ID: 10379913
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Two distinct events, section compression and loss of particles ("lost caps"), contribute to z-axis distortion and bias in optical disector counting.
    Baryshnikova LM; Von Bohlen Und Halbach O; Kaplan S; Von Bartheld CS
    Microsc Res Tech; 2006 Sep; 69(9):738-56. PubMed ID: 16845675
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Differential tissue shrinkage and compression in the z-axis: implications for optical disector counting in vibratome-, plastic- and cryosections.
    Gardella D; Hatton WJ; Rind HB; Rosen GD; von Bartheld CS
    J Neurosci Methods; 2003 Mar; 124(1):45-59. PubMed ID: 12648764
    [TBL] [Abstract][Full Text] [Related]  

  • 5. A brief update on physical and optical disector applications and sectioning-staining methods in neuroscience.
    Yurt KK; Kivrak EG; Altun G; Mohamed H; Ali F; Gasmalla HE; Kaplan S
    J Chem Neuroanat; 2018 Nov; 93():16-29. PubMed ID: 29496551
    [TBL] [Abstract][Full Text] [Related]  

  • 6. If you assume, you can make an ass out of u and me': a decade of the disector for stereological counting of particles in 3D space.
    Mayhew TM; Gundersen HJ
    J Anat; 1996 Feb; 188 ( Pt 1)(Pt 1):1-15. PubMed ID: 8655396
    [TBL] [Abstract][Full Text] [Related]  

  • 7. A new method for physical disector analyses of numbers and mean volumes of immunohistochemically labeled cells in paraffin sections.
    Hofmann I; Kemter E; Fiedler S; Theobalt N; Fonteyne L; Wolf E; Wanke R; Blutke A
    J Neurosci Methods; 2021 Sep; 361():109272. PubMed ID: 34216707
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Optical disector counting in cryosections and vibratome sections underestimates particle numbers: effects of tissue quality.
    Ward TS; Rosen GD; von Bartheld CS
    Microsc Res Tech; 2008 Jan; 71(1):60-8. PubMed ID: 17868132
    [TBL] [Abstract][Full Text] [Related]  

  • 9. [A computer-aided analysis system for counting the synaptic numerical density based on disector technique].
    Shen L; Zhang L; Huang H; Liu H; Nan Y; Shang J; Liao H
    Sheng Wu Yi Xue Gong Cheng Xue Za Zhi; 2000 Jun; 17(2):167-9. PubMed ID: 12557772
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Counting cells with stereology: random versus serial sectioning.
    Bertram JF; Bolender RP
    J Electron Microsc Tech; 1990 Jan; 14(1):32-8. PubMed ID: 2299416
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Thick methacrylate sections devoid of lost caps simplify stereological quantifications based on the optical fractionator design.
    Hasselholt S; Lykkesfeldt J; Overgaard Larsen J
    Anat Rec (Hoboken); 2015 Dec; 298(12):2141-50. PubMed ID: 26370738
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Verification of the disector method for counting neurons, with comments on the empirical method.
    Pover CM; Coggeshall RE
    Anat Rec; 1991 Dec; 231(4):573-8. PubMed ID: 1793182
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Distribution of Particles in the Z-axis of Tissue Sections: Relevance for Counting Methods.
    von Bartheld CS
    Neuroquantology; 2012; 10(1):66-75. PubMed ID: 23874137
    [TBL] [Abstract][Full Text] [Related]  

  • 14. A review of recent methods for efficiently quantifying immunogold and other nanoparticles using TEM sections through cells, tissues and organs.
    Mayhew TM; Mühlfeld C; Vanhecke D; Ochs M
    Ann Anat; 2009 Apr; 191(2):153-70. PubMed ID: 19135344
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Does the physical disector method provide an accurate estimation of sensory neuron number in rat dorsal root ganglia?
    Delaloye S; Kraftsik R; Kuntzer T; Barakat-Walter I
    J Neurosci Methods; 2009 Jan; 176(2):290-7. PubMed ID: 18824026
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Adaptation of the disector method to rare small organelles in TEM sections exemplified by counting synaptic bodies in the rat pineal gland.
    Jastrow H; Von Mach MA; Vollrath L
    J Anat; 1997 Oct; 191 ( Pt 3)(Pt 3):399-405. PubMed ID: 9418996
    [TBL] [Abstract][Full Text] [Related]  

  • 17. A consideration of neural counting methods.
    Coggeshall RE
    Trends Neurosci; 1992 Jan; 15(1):9-13. PubMed ID: 1374957
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Counting cells in sectioned material: a suite of techniques, tools, and tips.
    Williams RW; von Bartheld CS; Rosen GD
    Curr Protoc Neurosci; 2003 Nov; Chapter 1():Unit 1.11. PubMed ID: 18428578
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Unbiased estimation of chloroplast number in mesophyll cells: advantage of a genuine three-dimensional approach.
    Kubínová Z; Janácek J; Lhotáková Z; Kubínová L; Albrechtová J
    J Exp Bot; 2014 Feb; 65(2):609-20. PubMed ID: 24336344
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Analysis of differential shrinkage in frozen brain sections and its implications for the use of guard zones in stereology.
    Carlo CN; Stevens CF
    J Comp Neurol; 2011 Oct; 519(14):2803-10. PubMed ID: 21491430
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.