BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

177 related articles for article (PubMed ID: 11981070)

  • 1. Gadolinium as an alternative contrast agent for diagnostic and interventional angiographic procedures in patients with impaired renal function.
    Rieger J; Sitter T; Toepfer M; Linsenmaier U; Pfeifer KJ; Schiffl H
    Nephrol Dial Transplant; 2002 May; 17(5):824-8. PubMed ID: 11981070
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Renal effects of gadopentetate dimeglumine in patients with normal and impaired renal function.
    Hoffmann U; Fischereder M; Reil A; Fischer M; Link J; Krämer BK
    Eur J Med Res; 2005 Apr; 10(4):149-54. PubMed ID: 15946910
    [TBL] [Abstract][Full Text] [Related]  

  • 3. CO2 and gadopentetate dimeglumine as alternative contrast agents for malfunctioning dialysis grafts and fistulas.
    Spinosa DJ; Angle JF; Hagspiel KD; Schenk WG; Matsumoto AH
    Kidney Int; 1998 Sep; 54(3):945-50. PubMed ID: 9734621
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Renal insufficiency: gadopentetate dimeglumine as a radiographic contrast agent during peripheral vascular interventional procedures.
    Kaufman JA; Geller SC; Waltman AC
    Radiology; 1996 Feb; 198(2):579-81. PubMed ID: 8596869
    [TBL] [Abstract][Full Text] [Related]  

  • 5. [Low-osmolar gadodiamide as alternative contrast agent for diagnostic angiography and angiographic interventions in patients with renal insufficiency].
    Dinkel HP; Hoppe H; Baumgartner I; Do DD; Triller J
    Rofo; 2002 Jan; 174(1):56-61. PubMed ID: 11793285
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Lower extremity arteriography with use of iodinated contrast material or gadodiamide to supplement CO2 angiography in patients with renal insufficiency.
    Spinosa DJ; Angle JF; Hagspiel KD; Kern JA; Hartwell GD; Matsumoto AH
    J Vasc Interv Radiol; 2000 Jan; 11(1):35-43. PubMed ID: 10693711
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Safety of CO(2)- and gadodiamide-enhanced angiography for the evaluation and percutaneous treatment of renal artery stenosis in patients with chronic renal insufficiency.
    Spinosa DJ; Matsumoto AH; Angle JF; Hagspiel KD; Cage D; Bissonette EA; Koenig KG; Ayers CR; McConnell K
    AJR Am J Roentgenol; 2001 May; 176(5):1305-11. PubMed ID: 11312200
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Renal insufficiency: usefulness of gadodiamide-enhanced renal angiography to supplement CO2-enhanced renal angiography for diagnosis and percutaneous treatment.
    Spinosa DJ; Matsumoto AH; Angle JF; Hagspiel KD; McGraw JK; Ayers C
    Radiology; 1999 Mar; 210(3):663-72. PubMed ID: 10207465
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Gadopentate dimeglumine as an alternative contrast agent for use in interventional procedures.
    Hatrick AG; Jarosz JM; Irvine AT
    Clin Radiol; 1997 Dec; 52(12):948-52. PubMed ID: 9413971
    [TBL] [Abstract][Full Text] [Related]  

  • 10. The use of gadolinium chelates for X-ray digital subtraction angiography.
    Wagner HJ; Kalinowski M; Klose KJ; Alfke H
    Invest Radiol; 2001 May; 36(5):257-65. PubMed ID: 11323513
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Comparison between gadolinium and iodine contrast for percutaneous intervention in atherosclerotic renal artery stenosis: clinical outcomes.
    Kane GC; Stanson AW; Kalnicka D; Rosenthal DW; Lee CU; Textor SC; Garovic VD
    Nephrol Dial Transplant; 2008 Apr; 23(4):1233-40. PubMed ID: 18256017
    [TBL] [Abstract][Full Text] [Related]  

  • 12. [Gadolinium in arteriography and interventional radiology: 39 patients].
    Robert A; Bonneville F; Miralbes S; Huart JY; Cattin F; Quantin N; Bonneville JF
    J Radiol; 2002 Nov; 83(11):1759-63. PubMed ID: 12469013
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Gadolinium-enhanced digital subtraction angiography of hemodialysis fistulas: a diagnostic and therapeutic approach.
    Le Blanche AF; Tassart M; Deux JF; Rossert J; Bigot JM; Boudghene F
    AJR Am J Roentgenol; 2002 Oct; 179(4):1023-8. PubMed ID: 12239059
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Gadodiamide as an alternative contrast agent in intravenous digital subtraction angiography and interventional procedures of the upper extremity veins.
    Sancak T; Bilgic S; Sanldilek U
    Cardiovasc Intervent Radiol; 2002; 25(1):49-52. PubMed ID: 11907774
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Gadolinium-based contrast and carbon dioxide angiography to evaluate renal transplants for vascular causes of renal insufficiency and accelerated hypertension.
    Spinosa DJ; Matsumoto AH; Angle JF; Hagspiel KD; Isaacs RB; McCullough CS; Lobo PI
    J Vasc Interv Radiol; 1998; 9(6):909-16. PubMed ID: 9840034
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Gadolinium dimeglumine: an alternative contrast agent for digital subtraction angiography.
    Hammer FD; Goffette PP; Malaise J; Mathurin P
    Eur Radiol; 1999; 9(1):128-36. PubMed ID: 9933396
    [TBL] [Abstract][Full Text] [Related]  

  • 17. CO2 digital subtraction angiography for renal artery angioplasty in high-risk patients.
    Caridi JG; Stavropoulos SW; Hawkins IF
    AJR Am J Roentgenol; 1999 Dec; 173(6):1551-6. PubMed ID: 10584800
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Multicenter, double-blind, randomized, intraindividual crossover comparison of gadobenate dimeglumine and gadopentetate dimeglumine for MR angiography of peripheral arteries.
    Gerretsen SC; le Maire TF; Miller S; Thurnher SA; Herborn CU; Michaely HJ; Kramer H; Vanzulli A; Vymazal J; Wasser MN; Ballarati CE; Kirchin MA; Pirovano G; Leiner T
    Radiology; 2010 Jun; 255(3):988-1000. PubMed ID: 20501735
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Use of gadolinium-based angiography for renal artery stenting in a patient with renal insufficiency: A case report.
    Mannebach PC; Dieter RS; Marks DS
    Angiology; 2006; 57(4):526-9. PubMed ID: 17022392
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Azotemia: gadopentetate dimeglumine as contrast agent at digital subtraction angiography.
    Matchett WJ; McFarland DR; Russell DK; Sailors DM; Moursi MM
    Radiology; 1996 Nov; 201(2):569-71. PubMed ID: 8888260
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.