These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

255 related articles for article (PubMed ID: 11992517)

  • 1. Analysis of petrol and diesel vapour and vehicle engine exhaust gases using selected ion flow tube mass spectrometry.
    Smith D; Cheng P; Spanel P
    Rapid Commun Mass Spectrom; 2002; 16(11):1124-34. PubMed ID: 11992517
    [TBL] [Abstract][Full Text] [Related]  

  • 2. On-line analysis of diesel engine exhaust gases by selected ion flow tube mass spectrometry.
    Smith D; Spanĕl P; Dabill D; Cocker J; Rajan B
    Rapid Commun Mass Spectrom; 2004; 18(23):2830-8. PubMed ID: 15517528
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Control of aldehyde emissions in the diesel engines with alcoholic fuels.
    Krishna MV; Varaprasad CM; Reddy CV
    J Environ Sci Eng; 2006 Jan; 48(1):61-4. PubMed ID: 17913204
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Control of diesel gaseous and particulate emissions with a tube-type wet electrostatic precipitator.
    Saiyasitpanich P; Keener TC; Lu M; Liang F; Khang SJ
    J Air Waste Manag Assoc; 2008 Oct; 58(10):1311-7. PubMed ID: 18939778
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Direct analysis of diesel exhaust particles by fragmentation-free mass spectrometry using ion attachment mass spectrometry.
    Masaki H; Chen L; Korenaga T
    Environ Sci; 2006; 13(6):347-52. PubMed ID: 17273150
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Influence of water vapour on selected ion flow tube mass spectrometric analyses of trace gases in humid air and breath.
    Spanĕl P; Smith D
    Rapid Commun Mass Spectrom; 2000; 14(20):1898-906. PubMed ID: 11013418
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Combined use of gas chromatography and selected ion flow tube mass spectrometry for absolute trace gas quantification.
    Kubista J; Spanel P; Dryahina K; Workman C; Smith D
    Rapid Commun Mass Spectrom; 2006; 20(4):563-7. PubMed ID: 16419024
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Development of organic gas exhaust speciation profiles for nonroad spark-ignition and compression-ignition engines and equipment.
    Reichle LJ; Cook R; Yanca CA; Sonntag DB
    J Air Waste Manag Assoc; 2015 Oct; 65(10):1185-93. PubMed ID: 26452015
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Selected ion flow tube mass spectrometry (SIFT-MS) for on-line trace gas analysis.
    Smith D; Spanel P
    Mass Spectrom Rev; 2005; 24(5):661-700. PubMed ID: 15495143
    [TBL] [Abstract][Full Text] [Related]  

  • 10. The novel selected-ion flow tube approach to trace gas analysis of air and breath.
    Smith D; Spanel P
    Rapid Commun Mass Spectrom; 1996; 10(10):1183-98. PubMed ID: 8759327
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Influence of ethanol-gasoline blended fuel on emission characteristics from a four-stroke motorcycle engine.
    Jia LW; Shen MQ; Wang J; Lin MQ
    J Hazard Mater; 2005 Aug; 123(1-3):29-34. PubMed ID: 15923082
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Chemical composition of gas-phase organic carbon emissions from motor vehicles and implications for ozone production.
    Gentner DR; Worton DR; Isaacman G; Davis LC; Dallmann TR; Wood EC; Herndon SC; Goldstein AH; Harley RA
    Environ Sci Technol; 2013 Oct; 47(20):11837-48. PubMed ID: 24011064
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Real-time, high-resolution quantitative measurement of multiple soil gas emissions: selected ion flow tube mass spectrometry.
    Milligan DB; Wilson PF; Mautner MN; Freeman CG; McEwan MJ; Clough TJ; Sherlock RR
    J Environ Qual; 2002; 31(2):515-24. PubMed ID: 11931442
    [TBL] [Abstract][Full Text] [Related]  

  • 14. An investigation of the reactions of H3O+ and O2+ with NO, NO2, N2O and HNO2 in support of selected ion flow tube mass spectrometry.
    Spanel P; Smith D
    Rapid Commun Mass Spectrom; 2000; 14(8):646-51. PubMed ID: 10786901
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Studies on exhaust emissions of catalytic coated spark ignition engine with adulterated gasoline.
    Muralikrishna MV; Kishor K; Venkata Ramana Reddy Ch
    J Environ Sci Eng; 2006 Apr; 48(2):97-102. PubMed ID: 17913184
    [TBL] [Abstract][Full Text] [Related]  

  • 16. The use of selected ion flow tube mass spectrometry to detect and quantify polyamines in headspace gas and oral air.
    Ross BM; Babay S; Ladouceur C
    Rapid Commun Mass Spectrom; 2009 Dec; 23(24):3973-82. PubMed ID: 19918934
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Preparation and emission characteristics of ethanol-diesel fuel blends.
    Zhang RD; He H; Shi XY; Zhang CB; He BQ; Wang JX
    J Environ Sci (China); 2004; 16(5):793-6. PubMed ID: 15559814
    [TBL] [Abstract][Full Text] [Related]  

  • 18. An exploratory comparative study of volatile compounds in exhaled breath and emitted by skin using selected ion flow tube mass spectrometry.
    Turner C; Parekh B; Walton C; Spanel P; Smith D; Evans M
    Rapid Commun Mass Spectrom; 2008; 22(4):526-32. PubMed ID: 18215004
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Analysis of ketones by selected ion flow tube mass spectrometry.
    Smith D; Wang T; Spanĕl P
    Rapid Commun Mass Spectrom; 2003; 17(23):2655-60. PubMed ID: 14648904
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Chemometric analysis of diesel fuel for forensic and environmental applications.
    Hupp AM; Marshall LJ; Campbell DI; Smith RW; McGuffin VL
    Anal Chim Acta; 2008 Jan; 606(2):159-71. PubMed ID: 18082647
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 13.