3. Diagnostic evaluation of planar and tomographic ventilation/perfusion lung images in patients with suspected pulmonary emboli. Bajc M; Olsson CG; Olsson B; Palmer J; Jonson B Clin Physiol Funct Imaging; 2004 Sep; 24(5):249-56. PubMed ID: 15383080 [TBL] [Abstract][Full Text] [Related]
4. Tomographic imaging in the diagnosis of pulmonary embolism: a comparison between V/Q lung scintigraphy in SPECT technique and multislice spiral CT. Reinartz P; Wildberger JE; Schaefer W; Nowak B; Mahnken AH; Buell U J Nucl Med; 2004 Sep; 45(9):1501-8. PubMed ID: 15347717 [TBL] [Abstract][Full Text] [Related]
5. Assessment of clinical impact in the application of Chang attenuation correction to lung ventilation/perfusion SPECT. Izadyar S; Saber S; Gholamrezanezhad A J Nucl Med Technol; 2011 Dec; 39(4):290-4. PubMed ID: 21930669 [TBL] [Abstract][Full Text] [Related]
6. Screening of pulmonary embolism by ventilation / perfusion tomography-SPECT and comparation with planar scintigraphy--our experiences. Begic A; Begic A; Kucukalic-Selimovic E; Zutic H; Skopljak-Beganovic A Med Arh; 2008; 62(4):220-2. PubMed ID: 19145806 [TBL] [Abstract][Full Text] [Related]
7. Reproducibility of Lobar Perfusion and Ventilation Quantification Using SPECT/CT Segmentation Software in Lung Cancer Patients. Provost K; Leblond A; Gauthier-Lemire A; Filion É; Bahig H; Lord M J Nucl Med Technol; 2017 Sep; 45(3):185-192. PubMed ID: 28408698 [TBL] [Abstract][Full Text] [Related]
8. Pulmonary Scintigraphy for the Diagnosis of Acute Pulmonary Embolism: A Survey of Current Practices in Australia, Canada, and France. Le Roux PY; Pelletier-Galarneau M; De Laroche R; Hofman MS; Zuckier LS; Roach P; Vuillez JP; Hicks RJ; Le Gal G; Salaun PY J Nucl Med; 2015 Aug; 56(8):1212-7. PubMed ID: 26135110 [TBL] [Abstract][Full Text] [Related]
9. Pulmonary functional imaging: qualitative comparison of Fourier decomposition MR imaging with SPECT/CT in porcine lung. Bauman G; Lützen U; Ullrich M; Gaass T; Dinkel J; Elke G; Meybohm P; Frerichs I; Hoffmann B; Borggrefe J; Knuth HC; Schupp J; Prüm H; Eichinger M; Puderbach M; Biederer J; Hintze C Radiology; 2011 Aug; 260(2):551-9. PubMed ID: 21586678 [TBL] [Abstract][Full Text] [Related]
10. The Utility of Hybrid SPECT/CT Lung Perfusion Scintigraphy in Pulmonary Embolism Diagnosis. Mazurek A; Dziuk M; Witkowska-Patena E; Piszczek S; Gizewska A Respiration; 2015; 90(5):393-401. PubMed ID: 26418469 [TBL] [Abstract][Full Text] [Related]
11. Pulmonary scintigraphy in elastase-induced emphysema in pigs. Correlation with high-resolution computed tomography and histology. Noma S; Moskowitz GW; Herman PG; Khan A; Rojas KA Invest Radiol; 1992 Jun; 27(6):429-35. PubMed ID: 1607258 [TBL] [Abstract][Full Text] [Related]
12. 68Ga PET/CT ventilation-perfusion imaging for pulmonary embolism: a pilot study with comparison to conventional scintigraphy. Hofman MS; Beauregard JM; Barber TW; Neels OC; Eu P; Hicks RJ J Nucl Med; 2011 Oct; 52(10):1513-9. PubMed ID: 21908388 [TBL] [Abstract][Full Text] [Related]
13. Objective analysis of whole lung and lobar ventilation/perfusion relationships in pulmonary embolism. Harris B; Bailey DL; Chicco P; Bailey EA; Roach PJ; King GG Clin Physiol Funct Imaging; 2008 Jan; 28(1):14-26. PubMed ID: 18171400 [TBL] [Abstract][Full Text] [Related]
15. The conclusions drawn from ventilation/perfusion single-photon emission computed tomography compared with lung perfusion single-photon emission computed tomography and chest radiography in patients with suspected pulmonary thromboembolism. Abubakar S; Jacobs D; Kotze T Nucl Med Commun; 2018 Oct; 39(10):908-914. PubMed ID: 30048378 [TBL] [Abstract][Full Text] [Related]
16. Contribution of V/Q SPECT to planar scintigraphy in the diagnosis of pulmonary embolism. Quirce R; Ibáñez-Bravo S; Jiménez-Bonilla J; Martínez-Rodríguez I; Martínez-Amador N; Ortega-Nava F; Lavado-Pérez C; Bravo-Ferrer Z; Carril JM Rev Esp Med Nucl Imagen Mol; 2014; 33(3):153-8. PubMed ID: 24485808 [TBL] [Abstract][Full Text] [Related]
17. Coregistered ventilation and perfusion SPECT using krypton-81m and Tc-99m-labeled macroaggregated albumin with multislice CT utility for prediction of postoperative lung function in non-small cell lung cancer patients. Ohno Y; Koyama H; Takenaka D; Nogami M; Kotani Y; Nishimura Y; Yoshimura M; Yoshikawa T; Sugimura K Acad Radiol; 2007 Jul; 14(7):830-8. PubMed ID: 17574133 [TBL] [Abstract][Full Text] [Related]
18. Comparison of V/Q SPECT and planar V/Q lung scintigraphy in diagnosing acute pulmonary embolism. Gutte H; Mortensen J; Jensen CV; von der Recke P; Petersen CL; Kristoffersen US; Kjaer A Nucl Med Commun; 2010 Jan; 31(1):82-6. PubMed ID: 19918207 [TBL] [Abstract][Full Text] [Related]
19. Pulmonary thromboembolism: a retrospective study on the examination of 991 patients by ventilation/perfusion SPECT using Technegas. Lemb M; Pohlabeln H Nuklearmedizin; 2001 Dec; 40(6):179-86. PubMed ID: 11797505 [TBL] [Abstract][Full Text] [Related]
20. EANM guidelines for ventilation/perfusion scintigraphy : Part 1. Pulmonary imaging with ventilation/perfusion single photon emission tomography. Bajc M; Neilly JB; Miniati M; Schuemichen C; Meignan M; Jonson B; Eur J Nucl Med Mol Imaging; 2009 Aug; 36(8):1356-70. PubMed ID: 19562336 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]