178 related articles for article (PubMed ID: 11996049)
21. Spark plasma sintering synthesis of porous nanocrystalline titanium alloys for biomedical applications.
Nicula R; Lüthen F; Stir M; Nebe B; Burkel E
Biomol Eng; 2007 Nov; 24(5):564-7. PubMed ID: 17869173
[TBL] [Abstract][Full Text] [Related]
22. Additively manufactured Ti-29Nb-21Zr shows improved oxide polarization resistance versus Ti-6Al-4V in inflammatory simulating solution.
Kurtz MA; Wessinger AC; Mace A; Moreno-Reyes A; Gilbert JL
J Biomed Mater Res A; 2023 Oct; 111(10):1538-1553. PubMed ID: 37129046
[TBL] [Abstract][Full Text] [Related]
23. [Effect of fluoride ion on corrosion of two dental titanium alloys].
Cao BW; Chen L
Hua Xi Kou Qiang Yi Xue Za Zhi; 2010 Jun; 28(3):261-4. PubMed ID: 20635653
[TBL] [Abstract][Full Text] [Related]
24. Study on improved tribological properties by alloying copper to CP-Ti and Ti-6Al-4V alloy.
Wang S; Ma Z; Liao Z; Song J; Yang K; Liu W
Mater Sci Eng C Mater Biol Appl; 2015 Dec; 57():123-32. PubMed ID: 26354247
[TBL] [Abstract][Full Text] [Related]
25. Designing new biocompatible glass-forming Ti75-x Zr10 Nbx Si15 (x = 0, 15) alloys: corrosion, passivity, and apatite formation.
Abdi S; Oswald S; Gostin PF; Helth A; Sort J; Baró MD; Calin M; Schultz L; Eckert J; Gebert A
J Biomed Mater Res B Appl Biomater; 2016 Jan; 104(1):27-38. PubMed ID: 25611821
[TBL] [Abstract][Full Text] [Related]
26. Comparative corrosion study of Ti-Ta alloys for dental applications.
Mareci D; Chelariu R; Gordin DM; Ungureanu G; Gloriant T
Acta Biomater; 2009 Nov; 5(9):3625-39. PubMed ID: 19508903
[TBL] [Abstract][Full Text] [Related]
27. New surface-hardened, low-modulus, corrosion-resistant Ti-13Nb-13Zr alloy for total hip arthroplasty.
Davidson JA; Mishra AK; Kovacs P; Poggie RA
Biomed Mater Eng; 1994; 4(3):231-43. PubMed ID: 7950871
[TBL] [Abstract][Full Text] [Related]
28. In-vitro corrosion and wear of titanium alloys in the biological environment.
Khan MA; Williams RL; Williams DF
Biomaterials; 1996 Nov; 17(22):2117-26. PubMed ID: 8922597
[TBL] [Abstract][Full Text] [Related]
29. The corrosion behaviour of Ti-6Al-4V, Ti-6Al-7Nb and Ti-13Nb-13Zr in protein solutions.
Khan MA; Williams RL; Williams DF
Biomaterials; 1999 Apr; 20(7):631-7. PubMed ID: 10208405
[TBL] [Abstract][Full Text] [Related]
30. The effect of Pt and Pd alloying additions on the corrosion behavior of titanium in fluoride-containing environments.
Nakagawa M; Matono Y; Matsuya S; Udoh K; Ishikawa K
Biomaterials; 2005 May; 26(15):2239-46. PubMed ID: 15585225
[TBL] [Abstract][Full Text] [Related]
31. Electrochemical corrosion behavior and elasticity properties of Ti-6Al-xFe alloys for biomedical applications.
Lu J; Zhao Y; Niu H; Zhang Y; Du Y; Zhang W; Huo W
Mater Sci Eng C Mater Biol Appl; 2016 May; 62():36-44. PubMed ID: 26952395
[TBL] [Abstract][Full Text] [Related]
32. Monitoring of titanium base alloys-biofluids interface.
Popa MV; Demetrescu I; Suh SH; Vasilescu E; Drob P; Ionita D; Vasilescu C
Bioelectrochemistry; 2007 Nov; 71(2):126-34. PubMed ID: 17409027
[TBL] [Abstract][Full Text] [Related]
33. Biocompatibility of new low-cost (α + β)-type Ti-Mo-Fe alloys for long-term implantation.
Abdelrhman Y; Gepreel MA; Kobayashi S; Okano S; Okamoto T
Mater Sci Eng C Mater Biol Appl; 2019 Jun; 99():552-562. PubMed ID: 30889729
[TBL] [Abstract][Full Text] [Related]
34. Microstructure and mechanical properties of Ti-Zr-Cr biomedical alloys.
Wang P; Feng Y; Liu F; Wu L; Guan S
Mater Sci Eng C Mater Biol Appl; 2015 Jun; 51():148-52. PubMed ID: 25842119
[TBL] [Abstract][Full Text] [Related]
35. Corrosion resistance, mechanical properties, corrosion fatigue strength and cytocompatibility of new Ti alloys without Al and V.
Okazaki Y; Rao S; Ito Y; Tateishi T
Biomaterials; 1998 Jul; 19(13):1197-215. PubMed ID: 9720903
[TBL] [Abstract][Full Text] [Related]
36. Metallic biomaterials TiN-coated: corrosion analysis and biocompatibility.
Paschoal AL; Vanâncio EC; Canale Lde C; da Silva OL; Huerta-Vilca D; Motheo Ade J
Artif Organs; 2003 May; 27(5):461-4. PubMed ID: 12752209
[TBL] [Abstract][Full Text] [Related]
37. Tribological and corrosion behavior of friction stir processed Ti-CaP nanocomposites in simulated body fluid solution.
Farnoush H; Abdi Bastami A; Sadeghi A; Aghazadeh Mohandesi J; Moztarzadeh F
J Mech Behav Biomed Mater; 2013 Apr; 20():90-7. PubMed ID: 23455159
[TBL] [Abstract][Full Text] [Related]
38. Exposure effects of endotoxin-free titanium-based wear particles to human osteoblasts.
Costa BC; Alves AC; Toptan F; Pinto AM; Grenho L; Fernandes MH; Petrovykh DY; Rocha LA; Lisboa-Filho PN
J Mech Behav Biomed Mater; 2019 Jul; 95():143-152. PubMed ID: 30999211
[TBL] [Abstract][Full Text] [Related]
39. Screening on binary Zr-1X (X = Ti, Nb, Mo, Cu, Au, Pd, Ag, Ru, Hf and Bi) alloys with good in vitro cytocompatibility and magnetic resonance imaging compatibility.
Zhou FY; Qiu KJ; Li HF; Huang T; Wang BL; Li L; Zheng YF
Acta Biomater; 2013 Dec; 9(12):9578-87. PubMed ID: 23928334
[TBL] [Abstract][Full Text] [Related]
40. Tribocorrosion studies of metallic biomaterials: The effect of plasma nitriding and DLC surface modifications.
Zhao GH; Aune RE; Espallargas N
J Mech Behav Biomed Mater; 2016 Oct; 63():100-114. PubMed ID: 27348147
[TBL] [Abstract][Full Text] [Related]
[Previous] [Next] [New Search]