BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

418 related articles for article (PubMed ID: 11996053)

  • 1. Energy spectra, angular spread, fluence profiles and dose distributions of 6 and 18 MV photon beams: results of monte carlo simulations for a varian 2100EX accelerator.
    Ding GX
    Phys Med Biol; 2002 Apr; 47(7):1025-46. PubMed ID: 11996053
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Commissioning stereotactic radiosurgery beams using both experimental and theoretical methods.
    Ding GX; Duggan DM; Coffey CW
    Phys Med Biol; 2006 May; 51(10):2549-66. PubMed ID: 16675869
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Photonuclear dose calculations for high-energy photon beams from Siemens and Varian linacs.
    Chibani O; Ma CM
    Med Phys; 2003 Aug; 30(8):1990-2000. PubMed ID: 12945965
    [TBL] [Abstract][Full Text] [Related]  

  • 4. On Monte Carlo modeling of megavoltage photon beams: a revisited study on the sensitivity of beam parameters.
    Chibani O; Moftah B; Ma CM
    Med Phys; 2011 Jan; 38(1):188-201. PubMed ID: 21361187
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Dose discrepancies between Monte Carlo calculations and measurements in the buildup region for a high-energy photon beam.
    Ding GX
    Med Phys; 2002 Nov; 29(11):2459-63. PubMed ID: 12462709
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Monte Carlo study of in-field and out-of-field dose distributions from a linear accelerator operating with and without a flattening-filter.
    Almberg SS; Frengen J; Lindmo T
    Med Phys; 2012 Aug; 39(8):5194-203. PubMed ID: 22894444
    [TBL] [Abstract][Full Text] [Related]  

  • 7. A photon source model based on particle transport in a parameterized accelerator structure for Monte Carlo dose calculations.
    Ishizawa Y; Dobashi S; Kadoya N; Ito K; Chiba T; Takayama Y; Sato K; Takeda K
    Med Phys; 2018 Jul; 45(7):2937-2946. PubMed ID: 29772081
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Surface dosimetry for oblique tangential photon beams: a Monte Carlo simulation study.
    Chow JC; Grigorov GN
    Med Phys; 2008 Jan; 35(1):70-6. PubMed ID: 18293563
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Monte Carlo simulation of TrueBeam flattening-filter-free beams using varian phase-space files: comparison with experimental data.
    Belosi MF; Rodriguez M; Fogliata A; Cozzi L; Sempau J; Clivio A; Nicolini G; Vanetti E; Krauss H; Khamphan C; Fenoglietto P; Puxeu J; Fedele D; Mancosu P; Brualla L
    Med Phys; 2014 May; 41(5):051707. PubMed ID: 24784373
    [TBL] [Abstract][Full Text] [Related]  

  • 10. PENELOPE/PRIMO-calculated photon and electron spectra from clinical accelerators.
    Brualla L; Rodriguez M; Sempau J; Andreo P
    Radiat Oncol; 2019 Jan; 14(1):6. PubMed ID: 30634994
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Photon beam characterization and modelling for Monte Carlo treatment planning.
    Deng J; Jiang SB; Kapur A; Li J; Pawlicki T; Ma CM
    Phys Med Biol; 2000 Feb; 45(2):411-27. PubMed ID: 10701512
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Backscatter towards the monitor ion chamber in high-energy photon and electron beams: charge integration versus Monte Carlo simulation.
    Verhaegen F; Symonds-Tayler R; Liu HH; Nahum AE
    Phys Med Biol; 2000 Nov; 45(11):3159-70. PubMed ID: 11098896
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Monte Carlo modeling of a 6 and 18 MV Varian Clinac medical accelerator for in-field and out-of-field dose calculations: development and validation.
    Bednarz B; Xu XG
    Phys Med Biol; 2009 Feb; 54(4):N43-57. PubMed ID: 19141879
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Evaluation of latent variances in Monte Carlo dose calculations with Varian TrueBeam photon phase-spaces used as a particle source.
    Alhakeem E; Zavgorodni S
    Phys Med Biol; 2017 Dec; 63(1):01NT03. PubMed ID: 29205177
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Ionization chamber dosimetry of small photon fields: a Monte Carlo study on stopping-power ratios for radiosurgery and IMRT beams.
    Sánchez-Doblado F; Andreo P; Capote R; Leal A; Perucha M; Arráns R; Núñez L; Mainegra E; Lagares JI; Carrasco E
    Phys Med Biol; 2003 Jul; 48(14):2081-99. PubMed ID: 12894972
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Validation of a Monte Carlo model for multi leaf collimator based electron delivery.
    Kaluarachchi MM; Saleh ZH; Schwer ML; Klein EE
    Med Phys; 2020 Aug; 47(8):3586-3599. PubMed ID: 32324289
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Monte Carlo linear accelerator simulation of megavoltage photon beams: independent determination of initial beam parameters.
    Almberg SS; Frengen J; Kylling A; Lindmo T
    Med Phys; 2012 Jan; 39(1):40-7. PubMed ID: 22225273
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Electron contamination in 8 and 18 MV photon beams.
    Zhu TC; Palta JR
    Med Phys; 1998 Jan; 25(1):12-9. PubMed ID: 9472821
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Monte Carlo calculation of nine megavoltage photon beam spectra using the BEAM code.
    Sheikh-Bagheri D; Rogers DW
    Med Phys; 2002 Mar; 29(3):391-402. PubMed ID: 11930914
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Dosimetric characteristics of unflattened 6 MV photon beams of a clinical linear accelerator: a Monte Carlo study.
    Mesbahi A
    Appl Radiat Isot; 2007 Sep; 65(9):1029-36. PubMed ID: 17616465
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 21.