241 related articles for article (PubMed ID: 12005130)
1. Control of occupational exposure to hexavalent chromium and ozone in tubular wire arc-welding processes by replacement of potassium by lithium or by addition of zinc.
Dennis JH; French MJ; Hewitt PJ; Mortazavi SB; Redding CA
Ann Occup Hyg; 2002 Jan; 46(1):33-42. PubMed ID: 12005130
[TBL] [Abstract][Full Text] [Related]
2. Control of exposure to hexavalent chromium and ozone in gas metal arc welding of stainless steels by use of a secondary shield gas.
Dennis JH; French MJ; Hewitt PJ; Mortazavi SB; Redding CA
Ann Occup Hyg; 2002 Jan; 46(1):43-8. PubMed ID: 12005131
[TBL] [Abstract][Full Text] [Related]
3. Hexavalent chromium content in stainless steel welding fumes is dependent on the welding process and shield gas type.
Keane M; Stone S; Chen B; Slaven J; Schwegler-Berry D; Antonini J
J Environ Monit; 2009 Feb; 11(2):418-24. PubMed ID: 19212602
[TBL] [Abstract][Full Text] [Related]
4. Profiling stainless steel welding processes to reduce fume emissions, hexavalent chromium emissions and operating costs in the workplace.
Keane M; Siert A; Stone S; Chen BT
J Occup Environ Hyg; 2016; 13(1):1-8. PubMed ID: 26267301
[TBL] [Abstract][Full Text] [Related]
5. Control of exposure to hexavalent chromium concentration in shielded metal arc welding fumes by nano-coating of electrodes.
Sivapirakasam SP; Mohan S; Santhosh Kumar MC; Thomas Paul A; Surianarayanan M
Int J Occup Environ Health; 2017 Apr; 23(2):128-142. PubMed ID: 29460694
[TBL] [Abstract][Full Text] [Related]
6. Control of Cr6+ emissions from gas metal arc welding using a silica precursor as a shielding gas additive.
Topham N; Wang J; Kalivoda M; Huang J; Yu KM; Hsu YM; Wu CY; Oh S; Cho K; Paulson K
Ann Occup Hyg; 2012 Mar; 56(2):233-41. PubMed ID: 22104317
[TBL] [Abstract][Full Text] [Related]
7. Fume generation and content of total chromium and hexavalent chromium in flux-cored arc welding.
Yoon CS; Paik NW; Kim JH
Ann Occup Hyg; 2003 Nov; 47(8):671-80. PubMed ID: 14602674
[TBL] [Abstract][Full Text] [Related]
8. Double shroud delivery of silica precursor for reducing hexavalent chromium in welding fume.
Wang J; Kalivoda M; Guan J; Theodore A; Sharby J; Wu CY; Paulson K; Es-Said O
J Occup Environ Hyg; 2012; 9(12):733-42. PubMed ID: 23113576
[TBL] [Abstract][Full Text] [Related]
9. Selecting Processes to Minimize Hexavalent Chromium from Stainless Steel Welding: Eight welding processes/shielding gas combinations were assessed for generation of hexavalent chromium in stainless steel welding fumes.
Keane M; Siert A; Stone S; Chen B; Slaven J; Cumpston A; Antonini J
Weld J; 2012 Sep; 91(9):241s-246s. PubMed ID: 26690276
[TBL] [Abstract][Full Text] [Related]
10. Size-separated particle fractions of stainless steel welding fume particles - A multi-analytical characterization focusing on surface oxide speciation and release of hexavalent chromium.
Mei N; Belleville L; Cha Y; Olofsson U; Odnevall Wallinder I; Persson KA; Hedberg YS
J Hazard Mater; 2018 Jan; 342():527-535. PubMed ID: 28886565
[TBL] [Abstract][Full Text] [Related]
11. The effects of welding parameters on ultra-violet light emissions, ozone and CrVI formation in MIG welding.
Dennis JH; Mortazavi SB; French MJ; Hewitt PJ; Redding CR
Ann Occup Hyg; 1997 Jan; 41(1):95-104. PubMed ID: 9072953
[TBL] [Abstract][Full Text] [Related]
12. Exposure to hexavalent chromium in welders: Results of the WELDOX II field study.
Pesch B; Lehnert M; Weiss T; Kendzia B; Menne E; Lotz A; Heinze E; Behrens T; Gabriel S; Schneider W; Brüning T
Ann Work Expo Health; 2018 Mar; 62(3):351-361. PubMed ID: 29444199
[TBL] [Abstract][Full Text] [Related]
13. Airborne exposure to inhalable hexavalent chromium in welders and other occupations: Estimates from the German MEGA database.
Pesch B; Kendzia B; Hauptmann K; Van Gelder R; Stamm R; Hahn JU; Zschiesche W; Behrens T; Weiss T; Siemiatycki J; Lavoué J; Jöckel KH; Brüning T
Int J Hyg Environ Health; 2015 Jul; 218(5):500-6. PubMed ID: 25979374
[TBL] [Abstract][Full Text] [Related]
14. [Assessment of occupational exposure of welders based on determination of fumes and their components produced during stainless steel welding].
Stanisławska M; Janasik B; Trzcinka-Ochocka M
Med Pr; 2011; 62(4):359-68. PubMed ID: 21995105
[TBL] [Abstract][Full Text] [Related]
15. Laboratory measurement of hazardous fumes and gases at a point corresponding to breathing zone of welder during a CO2 arc welding.
Saito H; Ojima J; Takaya M; Iwasaki T; Hisanaga N; Tanaka S; Arito H
Ind Health; 2000 Jan; 38(1):69-78. PubMed ID: 10680313
[TBL] [Abstract][Full Text] [Related]
16. Levels and control of welding fume exposure to total particulate, hexavalent chromium, and manganese in contracted activities in an oil refinery setting (2008-2018).
Freire de Carvalho M; Kliebert J; Urbanus J
J Occup Environ Hyg; 2024 Jan; 21(1):35-46. PubMed ID: 37773093
[TBL] [Abstract][Full Text] [Related]
17. Study on the soluble and insoluble fume and hexavalent chromium emitted from a new covered electrode with micro and nano sized-sodium and potassium titanate-based flux.
Madhusoodhanan R; Paramashivan SS; Mohan S; Rajeshwari VB
Environ Sci Pollut Res Int; 2023 Sep; 30(42):95550-95565. PubMed ID: 37552445
[TBL] [Abstract][Full Text] [Related]
18. Characterization of Particulate Fume and Oxides Emission from Stainless Steel Plasma Cutting.
Wang J; Hoang T; Floyd EL; Regens JL
Ann Work Expo Health; 2017 Apr; 61(3):311-320. PubMed ID: 28355418
[TBL] [Abstract][Full Text] [Related]
19. Welding fumes from stainless steel gas metal arc processes contain multiple manganese chemical species.
Keane M; Stone S; Chen B
J Environ Monit; 2010 May; 12(5):1133-40. PubMed ID: 21491680
[TBL] [Abstract][Full Text] [Related]
20. Relation between various chromium compounds and some other elements in fumes from manual metal arc stainless steel welding.
Matczak W; Chmielnicka J
Br J Ind Med; 1993 Mar; 50(3):244-51. PubMed ID: 8457491
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]