These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

91 related articles for article (PubMed ID: 12005223)

  • 1. Evaluation of two Mg2+-selective electrodes by means of a flow-through device.
    Boguschewski FH; Seyfarth M; Heidrich JP
    Clin Chem Lab Med; 2002 Mar; 40(3):308-11. PubMed ID: 12005223
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Serum ionized magnesium: comparison of results obtained with three ion-selective analyzers.
    Huijgen HJ; Sanders R; Cecco SA; Rehak NN; Sanders GT; Elin RJ
    Clin Chem Lab Med; 1999 Apr; 37(4):465-70. PubMed ID: 10369119
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Characterization, standardization and experiences with KONE ISE for Mg2+.
    Lewenstam A; Blomqvist N; Ost J
    Scand J Clin Lab Invest Suppl; 1994; 217():37-43. PubMed ID: 7939383
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Clinically important intermethod differences for physiologically abnormal ionized magnesium results.
    Cecco SA; Hristova EN; Rehak NN; Elin RJ
    Am J Clin Pathol; 1997 Nov; 108(5):564-9. PubMed ID: 9353096
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Evaluation of an ionized magnesium-pH analyzer--NOVA 8.
    Thode J; Juul-Jørgensen B; Seibaek M; Elming H; Borresen E; Jordal R
    Scand J Clin Lab Invest; 1998 Apr; 58(2):127-33. PubMed ID: 9587164
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Clinical findings on human blood with the KONE ISE for Mg2+.
    Maj-Zurawska M
    Scand J Clin Lab Invest Suppl; 1994; 217():69-76. PubMed ID: 7939387
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Comparison of precision and effect of pH and calcium on the AVL and NOVA magnesium ion-selective electrodes.
    Elin RJ; Hristova EN; Cecco SA; Niemela JE; Rehak NN
    Scand J Clin Lab Invest Suppl; 1996; 224():203-10. PubMed ID: 8865437
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Analytical evaluation of Kone Microlyte determination of ionized magnesium.
    van Ingen HE; Huijgen HJ; Kok WT; Sanders GT
    Clin Chem; 1994 Jan; 40(1):52-5. PubMed ID: 8287544
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Measurement of free magnesium in blood, serum and plasma with an ion-sensitive electrode.
    Ising H; Bertschat F; Günther T; Jeremias E; Jeremias A
    Eur J Clin Chem Clin Biochem; 1995 Jun; 33(6):365-71. PubMed ID: 7578617
    [TBL] [Abstract][Full Text] [Related]  

  • 10. IFCC guideline for sampling, measuring and reporting ionized magnesium in plasma.
    Ben Rayana MC; Burnett RW; Covington AK; D'Orazio P; Fogh-Andersen N; Jacobs E; Külpmann WR; Kuwa K; Larsson L; Lewenstam A; Maas AH; Mager G; Naskalski JW; Okorodudu AO; Ritter C; St John A; ;
    Clin Chem Lab Med; 2008; 46(1):21-6. PubMed ID: 17663628
    [TBL] [Abstract][Full Text] [Related]  

  • 11. The effect of smoking on the serum ionized magnesium concentration is method-dependent.
    Niemela JE; Cecco SA; Rehak NN; Elin RJ
    Arch Pathol Lab Med; 1997 Oct; 121(10):1087-92. PubMed ID: 9341589
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Linearity and stability of the AVL and Nova magnesium and calcium ion-selective electrodes.
    Rehak NN; Cecco SA; Niemela JE; Hristova EN; Elin RJ
    Clin Chem; 1996 Jun; 42(6 Pt 1):880-7. PubMed ID: 8665679
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Falsely high ionized magnesium results by an ion-selective electrode method in severe hypomagnesemia.
    Csako G; Rehak NN; Elin RJ
    Eur J Clin Chem Clin Biochem; 1997 Sep; 35(9):701-9. PubMed ID: 9352233
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Evaluation of the Nova StatSensor® Xpress(TM) Creatinine point-of-care handheld analyzer.
    Kosack CS; de Kieviet W; Bayrak K; Milovic A; Page AL
    PLoS One; 2015; 10(4):e0122433. PubMed ID: 25886375
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Evaluation of an electrolyte analyser for measurement of concentrations of ionized calcium and magnesium in cats.
    Unterer S; Gerber B; Glaus TM; Hässig M; Reusch CE
    Vet Res Commun; 2005 Nov; 29(8):647-59. PubMed ID: 16369879
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Measurement of ionized calcium with five types of instruments. An external quality assessment.
    Uldall A; Fogh-Andersen N; Thode J; Boink AB; Kofstad J; Larsson L; Närvänen S; Pedersen KO; Weber T
    Scand J Clin Lab Invest; 1985 May; 45(3):255-61. PubMed ID: 4001830
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Ca2+ measurement with ion selective electrodes. The French coordinated evaluation of seven analyzers, for a better clinical relevance and acceptance.
    Gouget B; Gourmelin Y; Blanchet F; Capolaghi B; Feuillu A; Lagente M; Lardet G; Manceaux JC; Pasquier C; Turret M
    Ann Biol Clin (Paris); 1988; 46(7):419-34. PubMed ID: 3056127
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Guidelines for sampling, measuring and reporting ionized magnesium in undiluted serum, plasma or blood: International Federation of Clinical Chemistry and Laboratory Medicine (IFCC): IFCC Scientific Division, Committee on Point of Care Testing.
    Rayana MC; Burnett RW; Covington AK; D'Orazio P; Fogh-Andersen N; Jacobs E; Külpmann WR; Kuwa K; Larsson L; Lewenstam A; Maas AH; Mager G; Naskalski JH; Okorodudu AO; Ritter C; St John A
    Clin Chem Lab Med; 2005; 43(5):564-9. PubMed ID: 15899681
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Selectivity coefficients of ion-selective magnesium electrodes used for simultaneous determination of magnesium and calcium ions.
    Maj-Zurawska M; Lewenstam A
    Talanta; 2011 Dec; 87():295-301. PubMed ID: 22099682
    [TBL] [Abstract][Full Text] [Related]  

  • 20. [Determination of electrolytes in serum and plasma].
    Külpmann WR
    Wien Klin Wochenschr Suppl; 1992; 192():37-41. PubMed ID: 1502823
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 5.