These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

237 related articles for article (PubMed ID: 12006797)

  • 41. Estimation of arterial carbon dioxide by end-tidal and transcutaneous PCO2 measurements in ventilated children.
    Sivan Y; Eldadah MK; Cheah TE; Newth CJ
    Pediatr Pulmonol; 1992 Mar; 12(3):153-7. PubMed ID: 1641271
    [TBL] [Abstract][Full Text] [Related]  

  • 42. What is the potential role of transcutaneous carbon dioxide in guiding acute noninvasive ventilation?
    van Oppen JD; Daniel PS; Sovani MP
    Respir Care; 2015 Apr; 60(4):484-91. PubMed ID: 25406345
    [TBL] [Abstract][Full Text] [Related]  

  • 43. Estimating Arterial Partial Pressure of Carbon Dioxide in Ventilated Patients: How Valid Are Surrogate Measures?
    Nassar BS; Schmidt GA
    Ann Am Thorac Soc; 2017 Jun; 14(6):1005-1014. PubMed ID: 28570147
    [TBL] [Abstract][Full Text] [Related]  

  • 44. Noninvasive Measurement of Carbon Dioxide during One-Lung Ventilation with Low Tidal Volume for Two Hours: End-Tidal versus Transcutaneous Techniques.
    Zhang H; Wang DX
    PLoS One; 2015; 10(10):e0138912. PubMed ID: 26466140
    [TBL] [Abstract][Full Text] [Related]  

  • 45. Accuracy and utility of a continuous intra-arterial blood gas monitoring system in pediatric patients.
    Coule LW; Truemper EJ; Steinhart CM; Lutin WA
    Crit Care Med; 2001 Feb; 29(2):420-6. PubMed ID: 11246326
    [TBL] [Abstract][Full Text] [Related]  

  • 46. [The comparison of the value of end-tidal partial pressure of carbon dioxide after eupnoea and prolonged expiratory method in Department of Respiratory Medicine].
    Tan W; Liu F; Hou HJ; Dai B; Wang QH; Zhao HW; Kang J
    Zhonghua Wei Zhong Bing Ji Jiu Yi Xue; 2013 Oct; 25(10):608-13. PubMed ID: 24119698
    [TBL] [Abstract][Full Text] [Related]  

  • 47. Evaluation of a new combined transcutaneous measurement of PCO2/pulse oximetry oxygen saturation ear sensor in newborn patients.
    Bernet-Buettiker V; Ugarte MJ; Frey B; Hug MI; Baenziger O; Weiss M
    Pediatrics; 2005 Jan; 115(1):e64-8. PubMed ID: 15601814
    [TBL] [Abstract][Full Text] [Related]  

  • 48. Rapid assessment of ventilation by measurement of carbon dioxide elimination during high-frequency ventilation of kittens.
    Smith DW; Frankel LR; Walker JG; Cheng EY; Meredith KS; Mihm FG; Ariagno RL
    Pediatr Pulmonol; 1987; 3(6):406-12. PubMed ID: 3122154
    [TBL] [Abstract][Full Text] [Related]  

  • 49. High-frequency oscillatory ventilation in pediatric patients with acute respiratory failure.
    Ben Jaballah N; Khaldi A; Mnif K; Bouziri A; Belhadj S; Hamdi A; Kchaou W
    Pediatr Crit Care Med; 2006 Jul; 7(4):362-7. PubMed ID: 16738496
    [TBL] [Abstract][Full Text] [Related]  

  • 50. Continuous pH and Pco2 monitoring during respiratory failure in children with the Paratrend 7 inserted into the peripheral venous system.
    Tobias JD; Connors D; Strauser L; Johnson T
    J Pediatr; 2000 May; 136(5):623-7. PubMed ID: 10802494
    [TBL] [Abstract][Full Text] [Related]  

  • 51. Capnography monitoring during neurosurgery: reliability in relation to various intraoperative positions.
    Grenier B; Verchère E; Mesli A; Dubreuil M; Siao D; Vandendriessche M; Calès J; Maurette P
    Anesth Analg; 1999 Jan; 88(1):43-8. PubMed ID: 9895064
    [TBL] [Abstract][Full Text] [Related]  

  • 52. Transcutaneous PCO2 and PO2: a multicenter study of accuracy.
    Palmisano BW; Severinghaus JW
    J Clin Monit; 1990 Jul; 6(3):189-95. PubMed ID: 2199616
    [TBL] [Abstract][Full Text] [Related]  

  • 53. Comparison of noninvasive measurements of carbon dioxide tension during withdrawal from mechanical ventilation.
    Healey CJ; Fedullo AJ; Swinburne AJ; Wahl GW
    Crit Care Med; 1987 Aug; 15(8):764-8. PubMed ID: 3111790
    [TBL] [Abstract][Full Text] [Related]  

  • 54. Transcutaneous PCO2 monitoring in critically ill adults: clinical evaluation of a new sensor.
    Bendjelid K; Schütz N; Stotz M; Gerard I; Suter PM; Romand JA
    Crit Care Med; 2005 Oct; 33(10):2203-6. PubMed ID: 16215371
    [TBL] [Abstract][Full Text] [Related]  

  • 55. Accuracy and Interpretation of Transcutaneous Carbon Dioxide Monitoring in Critically Ill Children.
    Setar L; Lee JG; Sanchez-Pinto LN; Coates BM
    Pediatr Crit Care Med; 2024 Jun; ():. PubMed ID: 38935571
    [TBL] [Abstract][Full Text] [Related]  

  • 56. Mainstream end-tidal carbon dioxide monitoring in the neonatal intensive care unit.
    Rozycki HJ; Sysyn GD; Marshall MK; Malloy R; Wiswell TE
    Pediatrics; 1998 Apr; 101(4 Pt 1):648-53. PubMed ID: 9521950
    [TBL] [Abstract][Full Text] [Related]  

  • 57. Weaning with end-tidal CO2 and pulse oximetry.
    Thrush DN; Mentis SW; Downs JB
    J Clin Anesth; 1991; 3(6):456-60. PubMed ID: 1760168
    [TBL] [Abstract][Full Text] [Related]  

  • 58. DCO
    González-Pacheco N; Sánchez-Luna M; Arribas-Sánchez C; Santos-González M; Orden-Quinto C; Tendillo-Cortijo F
    Eur J Pediatr; 2020 Mar; 179(3):499-506. PubMed ID: 31823075
    [TBL] [Abstract][Full Text] [Related]  

  • 59. Noninvasive monitoring of carbon dioxide in infants and children with congenital heart disease: end-tidal versus transcutaneous techniques.
    Wilson J; Russo P; Russo J; Tobias JD
    J Intensive Care Med; 2005; 20(5):291-5. PubMed ID: 16145219
    [TBL] [Abstract][Full Text] [Related]  

  • 60. Noninvasive monitoring of end-tidal carbon dioxide tension via nasal cannulas in spontaneously breathing children with profound hypocarbia.
    Flanagan JF; Garrett JS; McDuffee A; Tobias JD
    Crit Care Med; 1995 Jun; 23(6):1140-2. PubMed ID: 7774228
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 12.