245 related articles for article (PubMed ID: 12006809)
41. [The effects of extrinsic positive end-expiratory pressure on work of breathing in patients with chronic obstructive pulmonary disease].
Kong W; Wang C; Yang Y; Huang K; Jiang C; Weng X
Zhonghua Nei Ke Za Zhi; 2001 Jun; 40(6):385-9. PubMed ID: 11798603
[TBL] [Abstract][Full Text] [Related]
42. Automatic tube compensation in patients after cardiac surgery: effects on oxygen consumption and breathing pattern.
Oczenski W; Kepka A; Krenn H; Fitzgerald RD; Schwarz S; Hörmann C
Crit Care Med; 2002 Jul; 30(7):1467-71. PubMed ID: 12130963
[TBL] [Abstract][Full Text] [Related]
43. The effect of a gas leak around the endotracheal tube on the mean tracheal pressure during mechanical ventilation.
Pérez Fontán JJ; Heldt GP; Gregory GA
Am Rev Respir Dis; 1985 Aug; 132(2):339-42. PubMed ID: 4026056
[TBL] [Abstract][Full Text] [Related]
44. Breathing pattern and workload during automatic tube compensation, pressure support and T-piece trials in weaning patients.
Kuhlen R; Max M; Dembinski R; Terbeck S; Jürgens E; Rossaint R
Eur J Anaesthesiol; 2003 Jan; 20(1):10-6. PubMed ID: 12553382
[TBL] [Abstract][Full Text] [Related]
45. Influence of pressure- and flow-triggered synchronous intermittent mandatory ventilation on inspiratory muscle work.
Sassoon CS; Del Rosario N; Fei R; Rheeman CH; Gruer SE; Mahutte CK
Crit Care Med; 1994 Dec; 22(12):1933-41. PubMed ID: 7988129
[TBL] [Abstract][Full Text] [Related]
46. Evaluation in animals of a system to estimate tracheal pressure from the endotracheal tube cuff.
Wilder NA; Orr J; Westenskow D
J Clin Monit; 1996 Jan; 12(1):11-6. PubMed ID: 8732811
[TBL] [Abstract][Full Text] [Related]
47. Effects of endotracheal tube size and ventilator settings on the mechanics of a test system during intermittent flow ventilation.
Farstad T; Bratlid D
Pediatr Pulmonol; 1991; 11(1):15-21. PubMed ID: 1923663
[TBL] [Abstract][Full Text] [Related]
48. Effect of tracheal gas insufflation on demand valve triggering and total work during continuous positive airway pressure ventilation.
Hoyt JD; Marini JJ; Nahum A
Chest; 1996 Sep; 110(3):775-83. PubMed ID: 8797426
[TBL] [Abstract][Full Text] [Related]
49. Elevated imposed work of breathing masquerading as ventilator weaning intolerance.
Kirton OC; DeHaven CB; Morgan JP; Windsor J; Civetta JM
Chest; 1995 Oct; 108(4):1021-5. PubMed ID: 7555113
[TBL] [Abstract][Full Text] [Related]
50. Spontaneously breathing lung model comparison of work of breathing between automatic tube compensation and pressure support.
Fujino Y; Uchiyama A; Mashimo T; Nishimura M
Respir Care; 2003 Jan; 48(1):38-45. PubMed ID: 12556260
[TBL] [Abstract][Full Text] [Related]
51. Additional inspiratory work of breathing imposed by tracheostomy tubes and non-ideal ventilator properties in critically ill patients.
Haberthür C; Fabry B; Stocker R; Ritz R; Guttmann J
Intensive Care Med; 1999 May; 25(5):514-9. PubMed ID: 10401948
[TBL] [Abstract][Full Text] [Related]
52. Endotracheal tube resistance and inertance in a model of mechanical ventilation of newborns and small infants-the impact of ventilator settings on tracheal pressure swings.
Hentschel R; Buntzel J; Guttmann J; Schumann S
Physiol Meas; 2011 Sep; 32(9):1439-51. PubMed ID: 21799238
[TBL] [Abstract][Full Text] [Related]
53. Effect of different inspiratory rise time and cycling off criteria during pressure support ventilation in patients recovering from acute lung injury.
Chiumello D; Pelosi P; Taccone P; Slutsky A; Gattinoni L
Crit Care Med; 2003 Nov; 31(11):2604-10. PubMed ID: 14605531
[TBL] [Abstract][Full Text] [Related]
54. An in vitro evaluation of the influence of neonatal endotracheal tube diameter and length on the work of breathing.
Miyake F; Suga R; Akiyama T; Namba F
Paediatr Anaesth; 2018 May; 28(5):458-462. PubMed ID: 29633434
[TBL] [Abstract][Full Text] [Related]
55. Imposed work and oxygen delivery during spontaneous breathing with adult disposable manual ventilators.
Hess D; Hirsch C; Marquis-D'Amico C; Kacmarek RM
Anesthesiology; 1994 Nov; 81(5):1256-63. PubMed ID: 7978485
[TBL] [Abstract][Full Text] [Related]
56. Reduced airway resistance and work of breathing during mechanical ventilation with an ultra-thin, two-stage polyurethane endotracheal tube (the Kolobow tube).
Velarde CA; Short BL; Rivera O; Seale W; Howard R; Kolobow T
Crit Care Med; 1997 Feb; 25(2):276-9. PubMed ID: 9034264
[TBL] [Abstract][Full Text] [Related]
57. Relationship between work of breathing provided by a ventilator and patients' inspiratory drive during pressure support ventilation; effects of inspiratory rise time.
Uchiyama A; Imanaka H; Taenaka N
Anaesth Intensive Care; 2001 Aug; 29(4):349-58. PubMed ID: 11512644
[TBL] [Abstract][Full Text] [Related]
58. Airway leak size in neonates and autocycling of three flow-triggered ventilators.
Bernstein G; Knodel E; Heldt GP
Crit Care Med; 1995 Oct; 23(10):1739-44. PubMed ID: 7587241
[TBL] [Abstract][Full Text] [Related]
59. Work of breathing associated with pressure support ventilation in two different ventilators.
Sanders RC; Thurman TL; Holt SJ; Taft K; Heulitt MJ
Pediatr Pulmonol; 2001 Jul; 32(1):62-70. PubMed ID: 11416878
[TBL] [Abstract][Full Text] [Related]
60. Work of breathing, inspiratory flow response, and expiratory resistance during continuous positive airway pressure with the ventilators EVITA-2, EVITA-4 and SV 300.
Calzia E; Lindner KH; Stahl W; Martin A; Radermacher P; Georgieff M
Intensive Care Med; 1998 Sep; 24(9):931-8. PubMed ID: 9803329
[TBL] [Abstract][Full Text] [Related]
[Previous] [Next] [New Search]