These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
196 related articles for article (PubMed ID: 12022525)
1. Intracoronary shunts reduce transient intraoperative myocardial dysfunction during off-pump coronary operations. Yeatman M; Caputo M; Narayan P; Ghosh AK; Ascione R; Ryder I; Angelini GD Ann Thorac Surg; 2002 May; 73(5):1411-7. PubMed ID: 12022525 [TBL] [Abstract][Full Text] [Related]
2. Haemodynamic changes during beating heart coronary surgery with the 'Bristol Technique'. Watters MP; Ascione R; Ryder IG; Ciulli F; Pitsis AA; Angelini GD Eur J Cardiothorac Surg; 2001 Jan; 19(1):34-40. PubMed ID: 11163558 [TBL] [Abstract][Full Text] [Related]
3. Occlusion versus shunting during MIDCAB: effects on left ventricular function and quality of anastomosis. Menon AK; Albes JM; Oberhoff M; Karsch KR; Ziemer G Ann Thorac Surg; 2002 May; 73(5):1418-23. PubMed ID: 12022526 [TBL] [Abstract][Full Text] [Related]
4. Hemodynamic changes during posterior vessel off-pump coronary artery bypass: comparison between deep pericardial sutures and vacuum-assisted apical suction device. Chang WI; Kim KB; Kim JH; Ham BM; Kim YL Ann Thorac Surg; 2004 Dec; 78(6):2057-62. PubMed ID: 15561035 [TBL] [Abstract][Full Text] [Related]
5. Intracoronary shunt prevents ischemia in off-pump coronary artery bypass surgery. Bergsland J; Lingaas PS; Skulstad H; Hol PK; Halvorsen PS; Andersen R; Småstuen M; Lundblad R; Svennevig J; Andersen K; Fosse E Ann Thorac Surg; 2009 Jan; 87(1):54-60. PubMed ID: 19101268 [TBL] [Abstract][Full Text] [Related]
6. Minimally Circulatory-Assisted On-Pump Beating Coronary Artery Bypass Grafting for Patients With Complex Conditions for Off-Pump Surgery. Mizuno T; Egi K; Sakai K; Oi K; Hachimaru T; Makita T; Oishi K; Arai H Artif Organs; 2017 Mar; 41(3):233-241. PubMed ID: 27782315 [TBL] [Abstract][Full Text] [Related]
8. Segmental clamp and distal perfusion technique for reducing myocardial ischemia during coronary onlay grafting on a beating heart. Minato N; Okada T; Kanemoto S; Zempo N Surg Today; 2018 May; 48(5):566-570. PubMed ID: 29318373 [TBL] [Abstract][Full Text] [Related]
9. Influence of intracoronary shunt on myocardial ischemic injury during off-pump coronary artery bypass surgery. Bozok S; İlhan G; Karamustafa H; Ozan Karakişi S; Tüfekçi N; Tomak Y; Bağci P; Emir M; Sener E J Cardiovasc Surg (Torino); 2013 Apr; 54(2):289-95. PubMed ID: 23337405 [TBL] [Abstract][Full Text] [Related]
10. Analysis of hemodynamic changes during beating heart surgical procedures. Mathison M; Edgerton JR; Horswell JL; Akin JJ; Mack MJ Ann Thorac Surg; 2000 Oct; 70(4):1355-60; discussion 1360-1. PubMed ID: 11081898 [TBL] [Abstract][Full Text] [Related]
11. Intracoronary shunt prevents left ventricular function impairment during beating heart coronary revascularization. Lucchetti V; Capasso F; Caputo M; Grimaldi G; Capece M; Brando G; Caprio S; Angelini GD Eur J Cardiothorac Surg; 1999 Mar; 15(3):255-9. PubMed ID: 10333019 [TBL] [Abstract][Full Text] [Related]
12. Hemodynamic changes during displacement of the beating heart using epicardial stabilization for off-pump coronary artery bypass graft surgery. Mishra M; Malhotra R; Mishra A; Meharwal ZS; Trehan N J Cardiothorac Vasc Anesth; 2002 Dec; 16(6):685-90. PubMed ID: 12486647 [TBL] [Abstract][Full Text] [Related]
13. Beating heart revascularization with minimal extracorporeal circulation in patients with a poor ejection fraction. Folliguet TA; Philippe F; Larrazet F; Dibie A; Czitrom D; Le Bret E; Bachet J; Laborde F Heart Surg Forum; 2002; 6(1):19-23. PubMed ID: 12611727 [TBL] [Abstract][Full Text] [Related]
14. Evaluation of serial haemodynamic changes during coronary artery anastomoses in patients undergoing off-pump coronary artery bypass graft surgery: initial experiences using two deep pericardial stay sutures and octopus tissue stabilizer. Shinn HK; Oh YJ; Kim SH; Lee JH; Lee CS; Kwak YL Eur J Cardiothorac Surg; 2004 Jun; 25(6):978-84. PubMed ID: 15144998 [TBL] [Abstract][Full Text] [Related]
15. Application of intraoperative arterial pressure-based cardiac output monitoring for patients undergoing coronary artery bypass grafting surgery. Lu JK; Zhu C; Jing H; Wang YJ; Qing EM Chin Med J (Engl); 2012 Jun; 125(12):2099-103. PubMed ID: 22884136 [TBL] [Abstract][Full Text] [Related]
16. Intracoronary shunt insertion prevents myocardial stunning in a juvenile porcine MIDCAB model absent of coronary artery disease. Dapunt OE; Raji MR; Jeschkeit S; Dhein S; Kuhn-Régnier F; Südkamp M; Fischer JH; Mehlhorn U Eur J Cardiothorac Surg; 1999 Feb; 15(2):173-8; discussion 178-9. PubMed ID: 10219550 [TBL] [Abstract][Full Text] [Related]
17. [Clinical studies in the effect of operative strategies on the hemodynamics in off-pump coronary artery bypass grafting]. Mei J; Wang YQ; Bao CR; Ding FB; Du QR; Xie X; Shen SE Zhonghua Wai Ke Za Zhi; 2008 Feb; 46(4):241-4. PubMed ID: 18683755 [TBL] [Abstract][Full Text] [Related]