These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

281 related articles for article (PubMed ID: 12030552)

  • 1. A non-invasive method for focusing ultrasound through the human skull.
    Clement GT; Hynynen K
    Phys Med Biol; 2002 Apr; 47(8):1219-36. PubMed ID: 12030552
    [TBL] [Abstract][Full Text] [Related]  

  • 2. A hemisphere array for non-invasive ultrasound brain therapy and surgery.
    Clement GT; Sun J; Giesecke T; Hynynen K
    Phys Med Biol; 2000 Dec; 45(12):3707-19. PubMed ID: 11131194
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Investigation of a large-area phased array for focused ultrasound surgery through the skull.
    Clement GT; White J; Hynynen K
    Phys Med Biol; 2000 Apr; 45(4):1071-83. PubMed ID: 10795992
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Micro-receiver guided transcranial beam steering.
    Clement GT; Hynynen K
    IEEE Trans Ultrason Ferroelectr Freq Control; 2002 Apr; 49(4):447-53. PubMed ID: 11989700
    [TBL] [Abstract][Full Text] [Related]  

  • 5. A Noninvasive Ultrasound Resonance Method for Detecting Skull Induced Phase Shifts May Provide a Signal for Adaptive Focusing.
    Deng L; Hughes A; Hynynen K
    IEEE Trans Biomed Eng; 2020 Sep; 67(9):2628-2637. PubMed ID: 31976875
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Ultrashort echo-time MRI versus CT for skull aberration correction in MR-guided transcranial focused ultrasound: In vitro comparison on human calvaria.
    Miller GW; Eames M; Snell J; Aubry JF
    Med Phys; 2015 May; 42(5):2223-33. PubMed ID: 25979016
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Comparison between MR and CT imaging used to correct for skull-induced phase aberrations during transcranial focused ultrasound.
    Leung SA; Moore D; Gilbo Y; Snell J; Webb TD; Meyer CH; Miller GW; Ghanouni P; Butts Pauly K
    Sci Rep; 2022 Aug; 12(1):13407. PubMed ID: 35927449
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Experimental demonstration of passive acoustic imaging in the human skull cavity using CT-based aberration corrections.
    Jones RM; O'Reilly MA; Hynynen K
    Med Phys; 2015 Jul; 42(7):4385-400. PubMed ID: 26133635
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Ultrasound focusing using magnetic resonance acoustic radiation force imaging: application to ultrasound transcranial therapy.
    Hertzberg Y; Volovick A; Zur Y; Medan Y; Vitek S; Navon G
    Med Phys; 2010 Jun; 37(6):2934-42. PubMed ID: 20632605
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Ex vivo optimisation of a heterogeneous speed of sound model of the human skull for non-invasive transcranial focused ultrasound at 1 MHz.
    Marsac L; Chauvet D; La Greca R; Boch AL; Chaumoitre K; Tanter M; Aubry JF
    Int J Hyperthermia; 2017 Sep; 33(6):635-645. PubMed ID: 28540778
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Characterization of ultrasound propagation through ex-vivo human temporal bone.
    Ammi AY; Mast TD; Huang IH; Abruzzo TA; Coussios CC; Shaw GJ; Holland CK
    Ultrasound Med Biol; 2008 Oct; 34(10):1578-89. PubMed ID: 18456391
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Transcranial Phase Correction Using Pulse-Echo Ultrasound and Deep Learning: A 2-D Numerical Study.
    Tian Z; Olmstead M; Jing Y; Han A
    IEEE Trans Ultrason Ferroelectr Freq Control; 2024 Jan; 71(1):117-126. PubMed ID: 38060357
    [TBL] [Abstract][Full Text] [Related]  

  • 13. A magnetic resonance imaging-compatible, large-scale array for trans-skull ultrasound surgery and therapy.
    Clement GT; White PJ; King RL; McDannold N; Hynynen K
    J Ultrasound Med; 2005 Aug; 24(8):1117-25. PubMed ID: 16040827
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Measurements of the Relationship Between CT Hounsfield Units and Acoustic Velocity and How It Changes With Photon Energy and Reconstruction Method.
    Webb TD; Leung SA; Rosenberg J; Ghanouni P; Dahl JJ; Pelc NJ; Pauly KB
    IEEE Trans Ultrason Ferroelectr Freq Control; 2018 Jul; 65(7):1111-1124. PubMed ID: 29993366
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Transcranial focused ultrasound phase correction using the hybrid angular spectrum method.
    Leung SA; Moore D; Webb TD; Snell J; Ghanouni P; Butts Pauly K
    Sci Rep; 2021 Mar; 11(1):6532. PubMed ID: 33753771
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Comparison Between Ray-Tracing and Full-Wave Simulation for Transcranial Ultrasound Focusing on a Clinical System Using the Transfer Matrix Formalism.
    Bancel T; Houdouin A; Annic P; Rachmilevitch I; Shapira Y; Tanter M; Aubry JF
    IEEE Trans Ultrason Ferroelectr Freq Control; 2021 Jul; 68(7):2554-2565. PubMed ID: 33651688
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Two-step aberration correction: application to transcranial histotripsy.
    Lu N; Hall TL; Sukovich JR; Choi SW; Snell J; McDannold N; Xu Z
    Phys Med Biol; 2022 Jun; 67(12):. PubMed ID: 35609619
    [No Abstract]   [Full Text] [Related]  

  • 18. The role of internal reflection in transskull phase distortion.
    Clement GT; Sun J; Hynynen K
    Ultrasonics; 2001 Mar; 39(2):109-13. PubMed ID: 11270628
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Focusing of therapeutic ultrasound through a human skull: a numerical study.
    Sun J; Hynynen K
    J Acoust Soc Am; 1998 Sep; 104(3 Pt 1):1705-15. PubMed ID: 9745750
    [TBL] [Abstract][Full Text] [Related]  

  • 20. A numerical study of transcranial focused ultrasound beam propagation at low frequency.
    Yin X; Hynynen K
    Phys Med Biol; 2005 Apr; 50(8):1821-36. PubMed ID: 15815098
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 15.