These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

121 related articles for article (PubMed ID: 12030559)

  • 21. Dosimetric characterization of the M-15 high-dose-rate Iridium-192 brachytherapy source using the AAPM and ESTRO formalism.
    Ho Than MT; Munro Iii JJ; Medich DC
    J Appl Clin Med Phys; 2015 May; 16(3):5270. PubMed ID: 26103489
    [TBL] [Abstract][Full Text] [Related]  

  • 22. A Monte Carlo calculation of dosimetric parameters of 90Sr/90Y and 192Ir SS sources for intravascular brachytherapy.
    Wang R; Li XA
    Med Phys; 2000 Nov; 27(11):2528-35. PubMed ID: 11128305
    [TBL] [Abstract][Full Text] [Related]  

  • 23. On the use of a novel Ferrous Xylenol-orange gelatin dosimeter for HDR brachytherapy commissioning and quality assurance testing.
    Pappas EP; Peppa V; Hourdakis CJ; Karaiskos P; Papagiannis P
    Phys Med; 2018 Jan; 45():162-169. PubMed ID: 29472082
    [TBL] [Abstract][Full Text] [Related]  

  • 24. In vivo dosimetry in the urethra using alanine/ESR during (192)Ir HDR brachytherapy of prostate cancer--a phantom study.
    Anton M; Wagner D; Selbach HJ; Hackel T; Hermann RM; Hess CF; Vorwerk H
    Phys Med Biol; 2009 May; 54(9):2915-31. PubMed ID: 19384000
    [TBL] [Abstract][Full Text] [Related]  

  • 25. The mean photon energy ĒF at the point of measurement determines the detector-specific radiation quality correction factor kQ,M in (192)Ir brachytherapy dosimetry.
    Chofor N; Harder D; Selbach HJ; Poppe B
    Z Med Phys; 2016 Sep; 26(3):238-50. PubMed ID: 26387927
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Air-kerma strength determination of an HDR
    Smith BR; Micka JA; Aima M; DeWerd LA; Culberson WS
    Med Phys; 2017 Jan; 44(1):311-320. PubMed ID: 28102953
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Comparison of calibration procedures for 192Ir high-dose-rate brachytherapy sources.
    Baltas D; Geramani K; Ioannidis GT; Hierholz K; Rogge B; Kolotas C; Müller-Sievers K; Milickovic N; Kober B; Zamboglou N
    Int J Radiat Oncol Biol Phys; 1999 Feb; 43(3):653-61. PubMed ID: 10078653
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Dosimetry close to an 192Ir HDR source using N-vinylpyrrolidone based polymer gels and magnetic resonance imaging.
    Papagiannis P; Pappas E; Kipouros P; Angelopoulos A; Sakelliou L; Baras P; Karaiskos P; Seimenis I; Sandilos P; Baltas D
    Med Phys; 2001 Jul; 28(7):1416-26. PubMed ID: 11488573
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Using LiF:Mg,Cu,P TLDs to estimate the absorbed dose to water in liquid water around an 192Ir brachytherapy source.
    Lucas PA; Aubineau-Lanièce I; Lourenço V; Vermesse D; Cutarella D
    Med Phys; 2014 Jan; 41(1):011711. PubMed ID: 24387503
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Measurement of the absorbed dose distribution near an 192Ir intravascular brachytherapy seed using a high-spatial-resolution gel dosimetry system.
    Massillon-JL G; Minniti R; Mitch MG; Soares CG
    Phys Med Biol; 2012 Jun; 57(11):3407-18. PubMed ID: 22572625
    [TBL] [Abstract][Full Text] [Related]  

  • 31. An evaluation of the TSE MR sequence for time efficient data acquisition in polymer gel dosimetry of applications involving high doses and steep dose gradients.
    Baras P; Seimenis I; Sandilos P; Vlahos L; Bieganski T; Georgiou E; Pantelis E; Papagiannis P; Sakelliou L
    Med Phys; 2005 Nov; 32(11):3339-45. PubMed ID: 16370420
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Comments on 'determination of the dose characteristics in the near area of a new type of 192Ir-HDR afterloading source with a pinpoint ionization chamber'.
    Ballester F
    Phys Med Biol; 2003 Mar; 48(5):L23-5; author reply L25-6. PubMed ID: 12696806
    [No Abstract]   [Full Text] [Related]  

  • 33. High beta and electron dose from 192Ir: implications for "gamma" intravascular brachytherapy.
    Patel NS; Chiu-Tsao ST; Ho Y; Duckworth T; Shih JA; Tsao HS; Quon H; Harrison LB
    Int J Radiat Oncol Biol Phys; 2002 Nov; 54(3):972-80. PubMed ID: 12377352
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Approaches to calculating AAPM TG-43 brachytherapy dosimetry parameters for 137Cs, 125I, 192Ir, 103Pd, and 169Yb sources.
    Melhus CS; Rivard MJ
    Med Phys; 2006 Jun; 33(6):1729-37. PubMed ID: 16872080
    [TBL] [Abstract][Full Text] [Related]  

  • 35. A generic TG-186 shielded applicator for commissioning model-based dose calculation algorithms for high-dose-rate
    Ma Y; Vijande J; Ballester F; Tedgren ÅC; Granero D; Haworth A; Mourtada F; Fonseca GP; Zourari K; Papagiannis P; Rivard MJ; Siebert FA; Sloboda RS; Smith R; Chamberland MJP; Thomson RM; Verhaegen F; Beaulieu L
    Med Phys; 2017 Nov; 44(11):5961-5976. PubMed ID: 28722180
    [TBL] [Abstract][Full Text] [Related]  

  • 36. A Monte Carlo study of verification imaging in high dose rate brachytherapy.
    Sheikh-Bagheri D; Munro P
    Med Phys; 1998 Apr; 25(4):404-14. PubMed ID: 9571606
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Experimental determination of the radial dose distribution in high gradient regions around 192Ir wires: comparison of electron paramagnetic resonance imaging, films, and Monte Carlo simulations.
    Kolbun N; Levêque P; Abboud F; Bol A; Vynckier S; Gallez B
    Med Phys; 2010 Oct; 37(10):5448-55. PubMed ID: 21089781
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Correction factors for source strength determination in HDR brachytherapy using the in-phantom method.
    Ubrich F; Wulff J; Engenhart-Cabillic R; Zink K
    Z Med Phys; 2014 May; 24(2):138-52. PubMed ID: 24021956
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Wide dynamic dose range of VIPAR polymer gel dosimetry.
    Kipouros P; Pappas E; Baras P; Hatzipanayoti D; Karaiskos P; Sakelliou L; Sandilos P; Seimenis I
    Phys Med Biol; 2001 Aug; 46(8):2143-59. PubMed ID: 11512616
    [TBL] [Abstract][Full Text] [Related]  

  • 40. A dosimetric comparison of 169Yb and 192Ir for HDR brachytherapy of the breast, accounting for the effect of finite patient dimensions and tissue inhomogeneities.
    Lymperopoulou G; Papagiannis P; Angelopoulos A; Karaiskos P; Georgiou E; Baltas D
    Med Phys; 2006 Dec; 33(12):4583-9. PubMed ID: 17278810
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 7.