These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

104 related articles for article (PubMed ID: 12043766)

  • 21. Open fractures of the tibia treated by immediate intramedullary tibial nail insertion without reaming: a prospective study.
    Kakar S; Tornetta P
    J Orthop Trauma; 2007 Mar; 21(3):153-7. PubMed ID: 17473750
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Prospective randomized study of reamed versus unreamed femoral intramedullary nailing: an assessment of procedures.
    Shepherd LE; Shean CJ; Gelalis ID; Lee J; Carter VS
    J Orthop Trauma; 2001 Jan; 15(1):28-32; discussion 32-3. PubMed ID: 11147684
    [TBL] [Abstract][Full Text] [Related]  

  • 23. [Systemic complications in intramedullary nailing].
    Wenda K; Runkel M
    Orthopade; 1996 Jun; 25(3):292-9. PubMed ID: 8766666
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Reaming does not add significant time to intramedullary nailing of diaphyseal fractures of the tibia and femur.
    Crist BD; Wolinsky PR
    J Trauma; 2009 Oct; 67(4):727-34. PubMed ID: 19820578
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Effect of limited and standard reaming on cortical bone blood flow and early strength of union following segmental fracture.
    Hupel TM; Aksenov SA; Schemitsch EH
    J Orthop Trauma; 1998 Aug; 12(6):400-6. PubMed ID: 9715447
    [TBL] [Abstract][Full Text] [Related]  

  • 26. The effect of retained intramedullary nails on tibial bone mineral density.
    Allen JC; Lindsey RW; Hipp JA; Gugala Z; Rianon N; LeBlanc A
    Clin Biomech (Bristol, Avon); 2008 Jul; 23(6):839-43. PubMed ID: 18367297
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Effect of acute reamed versus unreamed intramedullary nailing on compartment pressure when treating closed tibial shaft fractures: a randomized prospective study.
    Nassif JM; Gorczyca JT; Cole JK; Pugh KJ; Pienkowski D
    J Orthop Trauma; 2000 Nov; 14(8):554-8. PubMed ID: 11149501
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Reamed femoral nailing in sheep: does irrigation and aspiration of intramedullary contents alter the systemic response?
    Pape HC; Zelle BA; Hildebrand F; Giannoudis PV; Krettek C; van Griensven M
    J Bone Joint Surg Am; 2005 Nov; 87(11):2515-22. PubMed ID: 16264129
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Comparison of the effect of reamed and unreamed locked intramedullary nailing on blood flow in the callus and strength of union following fracture of the sheep tibia.
    Schemitsch EH; Kowalski MJ; Swiontkowski MF; Harrington RM
    J Orthop Res; 1995 May; 13(3):382-9. PubMed ID: 7602400
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Effect of unreamed, limited reamed, and standard reamed intramedullary nailing on cortical bone porosity and new bone formation.
    Hupel TM; Weinberg JA; Aksenov SA; Schemitsch EH
    J Orthop Trauma; 2001 Jan; 15(1):18-27. PubMed ID: 11147683
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Locking intramedullary nailing with and without reaming for open fractures of the tibial shaft. A prospective, randomized study.
    Keating JF; O'Brien PJ; Blachut PA; Meek RN; Broekhuyse HM
    J Bone Joint Surg Am; 1997 Mar; 79(3):334-41. PubMed ID: 9070520
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Prospective Randomized Clinical Trial Investigating the Effect of the Reamer-Irrigator-Aspirator on the Volume of Embolic Load and Respiratory Function During Intramedullary Nailing of Femoral Shaft Fractures.
    Hall JA; McKee MD; Vicente MR; Morison ZA; Dehghan N; Schemitsch CE; Kreder HJ; Petrisor B; Schemitsch EH
    J Orthop Trauma; 2017 Apr; 31(4):200-204. PubMed ID: 28323763
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Cortical bone blood flow in reamed and unreamed locked intramedullary nailing: a fractured tibia model in sheep.
    Schemitsch EH; Kowalski MJ; Swiontkowski MF; Senft D
    J Orthop Trauma; 1994 Oct; 8(5):373-82. PubMed ID: 7996319
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Comparison study between reamed and unreamed nailing of closed femoral fractures.
    Selvakumar K; Saw KY; Fathima M
    Med J Malaysia; 2001 Dec; 56 Suppl D():24-8. PubMed ID: 14569762
    [TBL] [Abstract][Full Text] [Related]  

  • 35. The treatment of femoral shaft fractures using intramedullary interlocked nails with and without intramedullary reaming: a preliminary report.
    Tornetta P; Tiburzi D
    J Orthop Trauma; 1997; 11(2):89-92. PubMed ID: 9057141
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Intramedullary nailing for tibial shaft fractures in adults.
    Duan X; Al-Qwbani M; Zeng Y; Zhang W; Xiang Z
    Cochrane Database Syst Rev; 2012 Jan; 1():CD008241. PubMed ID: 22258982
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Quantification of Reaming Debris at the Fracture Gap of Diaphyseal A2 and A3 Fractures After Reamed Intramedullary Nailing of the Sheep Tibia.
    Hoegel F; Abdulazim A; Augat P; Buehren V
    Eur J Trauma Emerg Surg; 2008 Dec; 34(6):587-91. PubMed ID: 26816284
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Periosteal microvascular reorganization after tibial reaming and intramedullary nailing in rats.
    Greksa F; Tóth K; Boros M; Szabó A
    J Orthop Sci; 2012 Jul; 17(4):477-83. PubMed ID: 22476427
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Effect of re-implanted particles from intramedullary reaming on mechanical properties and callus formation. A laboratory study.
    Hammer TO; Wieling R; Green JM; Südkamp NP; Schneider E; Müller CA
    J Bone Joint Surg Br; 2007 Nov; 89(11):1534-8. PubMed ID: 17998197
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Nonunion following intramedullary nailing of the femur with and without reaming. Results of a multicenter randomized clinical trial.
    Canadian Orthopaedic Trauma Society
    J Bone Joint Surg Am; 2003 Nov; 85(11):2093-6. PubMed ID: 14630836
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 6.