These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

111 related articles for article (PubMed ID: 12043824)

  • 1. Room scatter studies in the air kerma strength standardization of the Amersham CDCS-J-type 137Cs source: a Monte Carlo study.
    Selvam TP; Rajan KN; Nagarajan PS; Bhatt BC; Sethulakshmi P
    Phys Med Biol; 2002 May; 47(9):N113-9. PubMed ID: 12043824
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Monte Carlo aided room scatter studies in the primary air kerma strength standardization of a remote afterloading 192Ir HDR source.
    Selvam TP; Rajan KN; Nagarajan PS; Sethulakshmi P; Bhatt BC
    Phys Med Biol; 2001 Sep; 46(9):2299-315. PubMed ID: 11580170
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Monte Carlo aided room scatter corrections in the air-kerma strength standardization of 169Yb and 60Co brachytherapy sources.
    Selvam TP; Rajan KN; Sethulakshmi P; Bhatt BC
    Phys Med Biol; 2003 Jun; 48(11):N139-47. PubMed ID: 12817945
    [TBL] [Abstract][Full Text] [Related]  

  • 4. EGSnrc-based Monte Carlo dosimetry of CSA1 and CSA2 137Cs brachytherapy source models.
    Selvam TP; Sahoo S; Vishwakarma RS
    Med Phys; 2009 Sep; 36(9):3870-9. PubMed ID: 19810459
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Establishment of air kerma reference standard for low dose rate Cs-137 brachytherapy sources.
    Sharma SD; Kumar S; Srinivasan P; Chourasiya G
    J Appl Clin Med Phys; 2011 Nov; 12(4):3553. PubMed ID: 22089009
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Monte Carlo-based dose-rate tables for the Amersham CDCS.J and 3M model 6500 137Cs tubes.
    Williamson JF
    Int J Radiat Oncol Biol Phys; 1998 Jul; 41(4):959-70. PubMed ID: 9652865
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Dosimetric characteristics, air-kerma strength calibration and verification of Monte Carlo simulation for a new Ytterbium-169 brachytherapy source.
    Perera H; Williamson JF; Li Z; Mishra V; Meigooni AS
    Int J Radiat Oncol Biol Phys; 1994 Mar; 28(4):953-70. PubMed ID: 8138449
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Effect of source encapsulation on the energy spectra of 192Ir and 137Cs seed sources.
    Thomason C; Mackie TR; Lindstrom MJ
    Phys Med Biol; 1991 Apr; 36(4):495-505. PubMed ID: 2047398
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Dosimetric characterization of the M-15 high-dose-rate Iridium-192 brachytherapy source using the AAPM and ESTRO formalism.
    Ho Than MT; Munro Iii JJ; Medich DC
    J Appl Clin Med Phys; 2015 May; 16(3):5270. PubMed ID: 26103489
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Monte Carlo simulations of ceiling scatter in nuclear medicine:
    Schnerr RS; de Jong AN; Landry G; Jeukens CR; Wierts R
    Med Phys; 2017 Mar; 44(3):1113-1119. PubMed ID: 28097674
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Monte Carlo calculations of dose rate distributions around the Amersham CDCS-M-type 137Cs source.
    Casal E; Ballester F; Lluch JL; Pérez-Calatayud J; Lliso F
    Med Phys; 2000 Jan; 27(1):132-40. PubMed ID: 10659748
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Study of scattered radiation for in-air calibration by a multiple-distance method using ionization chambers and an HDR 192Ir brachytherapy source.
    Patel NP; Majumdar B; Vijayan V
    Br J Radiol; 2006 Apr; 79(940):347-52. PubMed ID: 16585730
    [TBL] [Abstract][Full Text] [Related]  

  • 13. A secondary air kerma strength standard for Yb-169 interstitial brachytherapy sources.
    Das RK; Mishra V; Perera H; Meigooni AS; Williamson JF
    Phys Med Biol; 1995 May; 40(5):741-56. PubMed ID: 7652005
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Simulation evaluation of NIST air-kerma rate calibration standard for electronic brachytherapy.
    Hiatt JR; Rivard MJ; Hughes HG
    Med Phys; 2016 Mar; 43(3):1119-29. PubMed ID: 26936699
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Monte Carlo and analytic calculation of absorbed dose near 137Cs intracavitary sources.
    Williamson JF
    Int J Radiat Oncol Biol Phys; 1988 Jul; 15(1):227-37. PubMed ID: 3391820
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Air-kerma strength determination of an HDR
    Smith BR; Micka JA; Aima M; DeWerd LA; Culberson WS
    Med Phys; 2017 Jan; 44(1):311-320. PubMed ID: 28102953
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Monte Carlo calculation of beam quality correction for solid-state detectors and phantom scatter correction at 137Cs energy.
    Selvam TP; Mishra S; Vishwakarma RS
    J Appl Clin Med Phys; 2014 Jan; 15(1):4445. PubMed ID: 24423840
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Spectra and air-kerma strength for encapsulated 192Ir sources.
    Borg J; Rogers DW
    Med Phys; 1999 Nov; 26(11):2441-4. PubMed ID: 10587230
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Direct measurement of air kerma rate in air from CDCS J-type caesium-137 therapy sources using a Farmer ionization chamber.
    Poynter AJ
    Br J Radiol; 2000 Apr; 73(868):425-8. PubMed ID: 10844869
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Dose calculation in brachytherapy for a 192Ir source using a primary and scatter dose separation technique.
    Russell KR; Ahnesjö A
    Phys Med Biol; 1996 Jun; 41(6):1007-24. PubMed ID: 8794481
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.