147 related articles for article (PubMed ID: 12045648)
1. A simplified approach to the diagnosis of elevated intra-abdominal pressure.
Lee SL; Anderson JT; Kraut EJ; Wisner DH; Wolfe BM
J Trauma; 2002 Jun; 52(6):1169-72. PubMed ID: 12045648
[TBL] [Abstract][Full Text] [Related]
2. Comparison of different methods for measuring intra-abdominal pressure.
Gudmundsson FF; Viste A; Gislason H; Svanes K
Intensive Care Med; 2002 Apr; 28(4):509-14. PubMed ID: 11967609
[TBL] [Abstract][Full Text] [Related]
3. Comparison of indirect methods of measuring intra-abdominal pressure in children.
Davis PJ; Koottayi S; Taylor A; Butt WW
Intensive Care Med; 2005 Mar; 31(3):471-5. PubMed ID: 15678316
[TBL] [Abstract][Full Text] [Related]
4. Estimation of intra-abdominal pressure by bladder pressure measurement: validity and methodology.
Fusco MA; Martin RS; Chang MC
J Trauma; 2001 Feb; 50(2):297-302. PubMed ID: 11242295
[TBL] [Abstract][Full Text] [Related]
5. Intra-abdominal pressure measurement method via the urinary-tube: bedside validation of a biomechanical model integrating urine column height and bladder urinary volume.
Vallee F; Dupas C; Feuvrier V; Mebazaa A; Ferre F; Mari A; Genestal M; Fourcade O
Ann Surg; 2010 Jan; 251(1):127-32. PubMed ID: 19864939
[TBL] [Abstract][Full Text] [Related]
6. Gastric and urinary bladder pressures correlate with intra-abdominal pressure in patients with morbid obesity.
Hamoud S; Abdelgani S; Mekel M; Kinaneh S; Mahajna A
J Clin Monit Comput; 2022 Aug; 36(4):1021-1028. PubMed ID: 34142275
[TBL] [Abstract][Full Text] [Related]
7. Comparison of direct and indirect methods of intra-abdominal pressure measurement in normal horses.
Munsterman AS; Hanson RR
J Vet Emerg Crit Care (San Antonio); 2009 Dec; 19(6):545-53. PubMed ID: 20017760
[TBL] [Abstract][Full Text] [Related]
8. Validation and experience with a simple continuous intra-abdominal pressure measurement technique in a multidisciplinary medical/surgical critical care unit.
Zengerink I; McBeth PB; Zygun DA; Ranson K; Ball CG; Laupland KB; Widder S; Kirkpatrick AW
J Trauma; 2008 May; 64(5):1159-64. PubMed ID: 18469635
[TBL] [Abstract][Full Text] [Related]
9. Gastric tonometry and direct intraabdominal pressure monitoring in abdominal compartment syndrome.
Engum SA; Kogon B; Jensen E; Isch J; Balanoff C; Grosfeld JL
J Pediatr Surg; 2002 Feb; 37(2):214-8. PubMed ID: 11819201
[TBL] [Abstract][Full Text] [Related]
10. Bedside measurement of intra-abdominal pressure (IAP) via an indwelling naso-gastric tube: clinical validation of the technique.
Collee GG; Lomax DM; Ferguson C; Hanson GC
Intensive Care Med; 1993; 19(8):478-80. PubMed ID: 8294633
[TBL] [Abstract][Full Text] [Related]
11. Determination of intra-abdominal pressure using a transurethral bladder catheter: clinical validation of the technique.
Iberti TJ; Lieber CE; Benjamin E
Anesthesiology; 1989 Jan; 70(1):47-50. PubMed ID: 2912315
[TBL] [Abstract][Full Text] [Related]
12. Intra-abdominal pressure measurement using a modified nasogastric tube: description and validation of a new technique.
Sugrue M; Buist MD; Lee A; Sanchez DJ; Hillman KM
Intensive Care Med; 1994 Nov; 20(8):588-90. PubMed ID: 7706574
[TBL] [Abstract][Full Text] [Related]
13. Continuous intra-abdominal pressure measurement technique.
Balogh Z; Jones F; D'Amours S; Parr M; Sugrue M
Am J Surg; 2004 Dec; 188(6):679-84. PubMed ID: 15619483
[TBL] [Abstract][Full Text] [Related]
14. Continuous intra-abdominal pressure monitoring.
Balogh Z; De Waele JJ; Malbrain ML
Acta Clin Belg; 2007; 62 Suppl 1():26-32. PubMed ID: 17469699
[TBL] [Abstract][Full Text] [Related]
15. Is clinical examination an accurate indicator of raised intra-abdominal pressure in critically injured patients?
Kirkpatrick AW; Brenneman FD; McLean RF; Rapanos T; Boulanger BR
Can J Surg; 2000 Jun; 43(3):207-11. PubMed ID: 10851415
[TBL] [Abstract][Full Text] [Related]
16. Determination and validation of volume to be instilled for standardized intra-abdominal pressure measurement in dogs.
Way LI; Monnet E
J Vet Emerg Crit Care (San Antonio); 2014; 24(4):403-7. PubMed ID: 25041693
[TBL] [Abstract][Full Text] [Related]
17. Increasing abdominal pressure with and without PEEP: effects on intra-peritoneal, intra-organ and intra-vascular pressures.
Jakob SM; Knuesel R; Tenhunen JJ; Pradl R; Takala J
BMC Gastroenterol; 2010 Jul; 10():70. PubMed ID: 20598159
[TBL] [Abstract][Full Text] [Related]
18. [Utility of intra-bladder pressure monitoring during closure of abdominal wall defects in newborn infants].
Nakayama M; Horikawa D; Nagai H; Tamiya K; Fujita S; Namiki A
Masui; 1992 Oct; 41(10):1647-50. PubMed ID: 1433839
[TBL] [Abstract][Full Text] [Related]
19. Noninvasive assessment of intra-abdominal pressure by measurement of abdominal wall tension.
van Ramshorst GH; Salih M; Hop WC; van Waes OJ; Kleinrensink GJ; Goossens RH; Lange JF
J Surg Res; 2011 Nov; 171(1):240-4. PubMed ID: 20462598
[TBL] [Abstract][Full Text] [Related]
20. Evaluation of a modified piezoresistive technique and a water-capsule technique for direct and continuous measurement of intra-abdominal pressure in a porcine model.
Schachtrupp A; Henzler D; Orfao S; Schaefer W; Schwab R; Becker P; Schumpelick V
Crit Care Med; 2006 Mar; 34(3):745-50. PubMed ID: 16505660
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]