These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

105 related articles for article (PubMed ID: 12052360)

  • 1. Measurement of ejection fraction with standard thermodilution catheters.
    dos Santos I; Ferreira da Rocha A; Assis de O Nascimento F; Souza Neto J; Valvano JW
    Med Eng Phys; 2002 Jun; 24(5):325-35. PubMed ID: 12052360
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Thermodilution right ventricular ejection fraction. Catheter positioning effects.
    Spinale FG; Zellner JL; Mukherjee R; Ferris SE; Crawford FA
    Chest; 1990 Nov; 98(5):1259-65. PubMed ID: 2225977
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Limitations of thermodilution ejection fraction: degradation of frequency response by catheter mounting of fast-response thermistors.
    Maruschak GF; Schauble JF
    Crit Care Med; 1985 Aug; 13(8):679-82. PubMed ID: 4017599
    [TBL] [Abstract][Full Text] [Related]  

  • 4. In vitro validation of a thermodilution right ventricular ejection fraction method.
    Ferris SE; Konno M
    J Clin Monit; 1992 Jan; 8(1):74-80. PubMed ID: 1538257
    [TBL] [Abstract][Full Text] [Related]  

  • 5. In vitro validation of a right ventricular thermodilution ejection fraction system.
    Mukherjee R; Spinale FG; von Recum AF; Crawford FA
    Ann Biomed Eng; 1991; 19(2):165-77. PubMed ID: 2048775
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Determination of right ventricular ejection fraction by thermodilution technique--a comparison to biplane cineventriculography.
    Voelker W; Gruber HP; Ickrath O; Unterberg R; Karsch KR
    Intensive Care Med; 1988; 14 Suppl 2():461-6. PubMed ID: 3403788
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Comparative evaluation of thermodilution and gated blood pool method for determination of right ventricular ejection fraction at rest and during exercise.
    Perings SM; Perings C; Kelm M; Strauer BE
    Cardiology; 2001; 95(3):161-3. PubMed ID: 11474163
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Thermodilution measurement of right ventricular ejection fraction with a modified pulmonary artery catheter.
    Vincent JL; Thirion M; Brimioulle S; Lejeune P; Kahn RJ
    Intensive Care Med; 1986; 12(1):33-8. PubMed ID: 3711424
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Monitoring of right ventricular function using a conventional slow response thermistor catheter.
    Lichtwarck-Aschoff M; Leucht S; Kisch HW; Zimmermann G; Blümel G; Pfeiffer UJ
    Intensive Care Med; 1994 May; 20(5):348-53. PubMed ID: 7930029
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Right atrial effects on right ventricular ejection fraction derived from thermodilution measurements.
    Santamore WP; Gefen N; Avramovich A; Berger P; Kashem A; Barnea O
    J Cardiothorac Vasc Anesth; 2007 Oct; 21(5):644-9. PubMed ID: 17905267
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Effects of the time response of the temperature sensor on thermodilution measurements.
    da Rocha AF; dos Santos I; Nascimento FA; Melo MD; Haemmerich D; Valvano JW
    Physiol Meas; 2005 Dec; 26(6):885-901. PubMed ID: 16311439
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Improved accuracy and precision of thermodilution cardiac output measurement using a dual thermistor catheter system.
    Lehmann KG; Platt MS
    J Am Coll Cardiol; 1999 Mar; 33(3):883-91. PubMed ID: 10080494
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Thermodilution right ventricular ejection fraction measurements: room temperature versus cold temperature injectate.
    Safcsak K; Nelson LD
    Crit Care Med; 1994 Jul; 22(7):1136-41. PubMed ID: 8026203
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Placement considerations for measuring thermodilution right ventricular ejection fractions.
    Spinale FG; Zellner JL; Mukherjee R; Crawford FA
    Crit Care Med; 1991 Mar; 19(3):417-21. PubMed ID: 1999105
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Thermodilution measurement of the right ventricular ejection fraction.
    Morrison DA; Stovall R; Sensecqua J; Friefeld G
    Cathet Cardiovasc Diagn; 1987; 13(3):167-73. PubMed ID: 3594558
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Thermodilution right ventricular ejection fraction measurement reproducibility--a study in patients undergoing coronary artery bypass graft surgery.
    Rafferty T; Durkin M; Hines R; Elefteriades J; Harris SN; O'Connor TZ
    Crit Care Med; 1992 Nov; 20(11):1524-8. PubMed ID: 1424694
    [TBL] [Abstract][Full Text] [Related]  

  • 17. [Measurement of the right ventricular ejection fraction by a rapid response thermistor catheter; evaluation using a circulatory model].
    Kato K; Kani H; Arii H; Imai T; Fujita T
    Masui; 1986 Dec; 35(12):1778-83. PubMed ID: 3560406
    [No Abstract]   [Full Text] [Related]  

  • 18. Measurement of right ventricular ejection fraction and volume by the thermodilution technique in the unsedated calf.
    Amory H; McEntee K; Linden A; Desmecht D; Lekeux P
    Res Vet Sci; 1994 Jan; 56(1):75-81. PubMed ID: 8146457
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Revascularization of the right coronary artery: influence on thermodilution right ventricular ejection fraction.
    Boldt J; Kling D; Thiel A; Scheld HH; Hempelmann G
    J Cardiothorac Anesth; 1988 Apr; 2(2):140-6. PubMed ID: 17171904
    [TBL] [Abstract][Full Text] [Related]  

  • 20. The measurement of right ventricular ejection fraction by thermodilution. A comparison of values obtained using differing injectate ports.
    Cockroft S; Withington PS
    Anaesthesia; 1993 Apr; 48(4):312-4. PubMed ID: 8494132
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.