BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

328 related articles for article (PubMed ID: 12056741)

  • 1. Recurrent thrombosis of prosthetic mitral valve in idiopathic hypereosinophilic syndrome.
    Watanabe K; Tournilhac O; Camilleri LF
    J Heart Valve Dis; 2002 May; 11(3):447-9. PubMed ID: 12056741
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Mitral valve repair in idiopathic hypereosinophilic syndrome.
    Fuzellier JF; Chapoutot L; Torossian PF
    J Heart Valve Dis; 2004 May; 13(3):529-31. PubMed ID: 15222304
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Mitral valve replacement in idiopathic eosinophilic endocarditis without peripheral eosinophilia.
    Fuzellier JF; Chapoutot L; Torossian PF; Metz D; Baehrel B
    J Card Surg; 2005; 20(5):472-4. PubMed ID: 16153283
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Obstructive prosthetic mitral valve thrombosis in idiopathic hypereosinophilic syndrome: a case report and review of the literature.
    Hii MW; Firkin FC; MacIsaac AI; Yii M
    J Heart Valve Dis; 2006 Sep; 15(5):721-5. PubMed ID: 17044382
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Bioprosthetic valve replacement in idiopathic hypereosinophilic syndrome with mitral valve involvement.
    Fang Q; Gu TX; Xiu ZY; Zhang ZW
    J Thorac Cardiovasc Surg; 2013 Nov; 146(5):e45-7. PubMed ID: 24001347
    [No Abstract]   [Full Text] [Related]  

  • 6. Recurrent native and prosthetic mitral valve thrombosis in idiopathic hypereosinophilic syndrome.
    Zakhama L; Slama I; Boussabah E; Harbegue B; Mimouni M; Abdelaali N; Sioua S; Thameur M; Benyoussef S
    J Heart Valve Dis; 2014 Mar; 23(2):168-70. PubMed ID: 25076546
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Unique presentation of hypereosinophilic syndrome: recurrent mitral prosthetic valve thrombosis without endomyocardial disease.
    Jánoskuti L; Förhécz Z; Lengyel M
    J Heart Valve Dis; 2006 Sep; 15(5):726-9. PubMed ID: 17044383
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Reoperative minimally invasive mitral valve replacement for bovine pericardial valve thrombosis secondary to idiopathic hypereosinophilic syndrome.
    Chu MW; Adams C; Yared K; Ball W; Dhingra S; Rosenbloom A
    Can J Cardiol; 2011; 27(6):868.e11-3. PubMed ID: 21664795
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Recurrent prosthetic valve dysfunction in a patient with idiopathic hypereosinophilic syndrome: A case report and literature review.
    Wei Z; Guo H; Li J; Lai Y
    J Card Surg; 2021 Nov; 36(11):4400-4402. PubMed ID: 34420238
    [TBL] [Abstract][Full Text] [Related]  

  • 10. [Findings of the Carpentier-Edwards porcine bioprosthesis in the mitral position with PTF in the 16th post-operative year].
    Matsuzaki K; Koishizawa T; Hiramatsu Y
    Kyobu Geka; 1997 Oct; 50(11):950-3. PubMed ID: 9330518
    [TBL] [Abstract][Full Text] [Related]  

  • 11. [Mitral valve replacement in idiopathic hypereosinophilic syndrome].
    Inoue K; Saida K; Yamashiro M; Yamada M; Funami M; Takaba T
    Nihon Kyobu Geka Gakkai Zasshi; 1991 Nov; 39(11):2068-73. PubMed ID: 1774488
    [TBL] [Abstract][Full Text] [Related]  

  • 12. [Anesthetic management for mitral valve replacement in a patient with idiopathic hypereosinophilic syndrome].
    Nonaka A; Suzuki S; Imamura M; Kumazawa T
    Masui; 2001 Jan; 50(1):34-6. PubMed ID: 11211746
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Multiple Valvular Complications of Hypereosinophilic Syndrome.
    Pozsonyi Z; Benedek S; Sármán P; Jánoskuti L; Hüttl T; Apor A
    J Heart Valve Dis; 2016 Nov; 25(6):752-755. PubMed ID: 28290178
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Recurrent stuck mitral valve: eosinophilia an unusual pathology.
    Awasthy N; Bhat Y; Radhakrishnan S; Sharma R
    Pediatr Cardiol; 2015 Mar; 36(3):692-3. PubMed ID: 25586257
    [TBL] [Abstract][Full Text] [Related]  

  • 15. [Severe mixed prosthetic double-discs mitral valve dysfunction due to thrombosis - a case report].
    Jedliński I; Duszyńska M; Wojna J; Kulczak M; Kalawski R; Poprawski K
    Kardiol Pol; 2009 Jan; 67(1):58-60; discussion 61. PubMed ID: 19253192
    [TBL] [Abstract][Full Text] [Related]  

  • 16. [Recurrent thromboses of the Björk-Shiley valve in a patient with gout].
    Isoda S; Kondo J; Imoto K; Kajiwara H; Matsumoto A
    Nihon Kyobu Geka Gakkai Zasshi; 1992 Jun; 40(6):1006-9. PubMed ID: 1634829
    [TBL] [Abstract][Full Text] [Related]  

  • 17. [Emergent mitral valve replacement in the second trimester of pregnancy].
    Sudoh Y; Takahara Y; Sunazawa T; Satoh T; Ishikawa H
    Nihon Kyobu Geka Gakkai Zasshi; 1997 Jul; 45(7):1034-8. PubMed ID: 9256646
    [TBL] [Abstract][Full Text] [Related]  

  • 18. [A case report of thrombosed St. Jude Medical valve in a patient with macroglobulinemia].
    Takemura T; Shiikawa A; Kitamura M; Aomi S; Endo M; Hashimoto A; Koyanagi H
    Kyobu Geka; 1992 Apr; 45(4):359-62. PubMed ID: 1564817
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Transjugular and transseptal treatment of a degenerated mitral valve prosthesis with a balloon-expandable biological valve.
    Schaefer U; Frerker C; Busse C; Kuck KH
    Heart Lung Circ; 2012 Dec; 21(12):836-40. PubMed ID: 22658887
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Bioprosthetic mitral valve stenosis secondary to hypereosinophilic syndrome.
    Quan X; Song Y; Wang H; Yang S; Zhu Z
    Echocardiography; 2022 Apr; 39(4):626-630. PubMed ID: 35220616
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 17.