These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

295 related articles for article (PubMed ID: 12059081)

  • 1. Evaluation of uncertainty of measurement in routine clinical chemistry--applications to determination of the substance concentration of calcium and glucose in serum.
    Linko S; Ornemark U; Kessel R; Taylor PD
    Clin Chem Lab Med; 2002 Apr; 40(4):391-8. PubMed ID: 12059081
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Description of a generally applicable model for the evaluation of uncertainty of measurement in clinical chemistry.
    Kristiansen J
    Clin Chem Lab Med; 2001 Oct; 39(10):920-31. PubMed ID: 11758604
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Measurement repeatability profiles of eight frequently requested measurands in clinical chemistry determined by duplicate measurements of patient samples.
    Kallner A; Petersmann A; Nauck M; Theodorsson E
    Scand J Clin Lab Invest; 2020 May; 80(3):202-209. PubMed ID: 31971449
    [TBL] [Abstract][Full Text] [Related]  

  • 4. The Guide to expression of uncertainty in measurement approach for estimating uncertainty: an appraisal.
    Kristiansen J
    Clin Chem; 2003 Nov; 49(11):1822-9. PubMed ID: 14578313
    [TBL] [Abstract][Full Text] [Related]  

  • 5. An approach for estimating measurement uncertainty in medical laboratories using data from long-term quality control and external quality assessment schemes.
    Padoan A; Antonelli G; Aita A; Sciacovelli L; Plebani M
    Clin Chem Lab Med; 2017 Oct; 55(11):1696-1701. PubMed ID: 28245184
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Pre-analytical factors and measurement uncertainty.
    Kouri T; Siloaho M; Pohjavaara S; Koskinen P; Malminiemi O; Pohja-Nylander P; Puukka R
    Scand J Clin Lab Invest; 2005; 65(6):463-75. PubMed ID: 16179279
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Measurement uncertainty in clinical chemistry: ISO 20914 versus nordtest or intermediate precision versus bias.
    Nurlu N; Cat A; Ucar KT
    Scand J Clin Lab Invest; 2024 May; 84(3):147-153. PubMed ID: 38742707
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Evaluation of measurement uncertainty of glucose in clinical chemistry.
    Berçik Inal B; Koldas M; Inal H; Coskun C; Gümüs A; Döventas Y
    Ann N Y Acad Sci; 2007 Apr; 1100():223-6. PubMed ID: 17460183
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Managing quality vs. measuring uncertainty in the medical laboratory.
    Westgard JO
    Clin Chem Lab Med; 2010; 48(1):31-40. PubMed ID: 19919330
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Defining permissible limits for the combined uncertainty budget in the implementation of metrological traceability.
    Braga F; Panteghini M
    Clin Biochem; 2018 Jul; 57():7-11. PubMed ID: 29526674
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Desirable routine analytical goals for quantities assayed in serum. Discussion paper from the members of the external quality assessment (EQA) Working Group A on analytical goals in laboratory medicine.
    Stöckl D; Baadenhuijsen H; Fraser CG; Libeer JC; Petersen PH; Ricós C
    Eur J Clin Chem Clin Biochem; 1995 Mar; 33(3):157-69. PubMed ID: 7605829
    [TBL] [Abstract][Full Text] [Related]  

  • 12. The role of external quality assessment in the verification of in vitro medical diagnostics in the traceability era.
    Braga F; Pasqualetti S; Panteghini M
    Clin Biochem; 2018 Jul; 57():23-28. PubMed ID: 29428441
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Routine internal- and external-quality control data in clinical laboratories for estimating measurement and diagnostic uncertainty using GUM principles.
    Magnusson B; Ossowicki H; Rienitz O; Theodorsson E
    Scand J Clin Lab Invest; 2012 May; 72(3):212-20. PubMed ID: 22233479
    [TBL] [Abstract][Full Text] [Related]  

  • 14. The accuracy of laboratory measurements in clinical chemistry: a study of 11 routine chemistry analytes in the College of American Pathologists Chemistry Survey with fresh frozen serum, definitive methods, and reference methods.
    Ross JW; Miller WG; Myers GL; Praestgaard J
    Arch Pathol Lab Med; 1998 Jul; 122(7):587-608. PubMed ID: 9674541
    [TBL] [Abstract][Full Text] [Related]  

  • 15. [Analytical uncertainty--how wrong can a laboratory result be?].
    Bolann BJ; Stølsnes B
    Tidsskr Nor Laegeforen; 1999 Dec; 119(30):4472-5. PubMed ID: 10827487
    [TBL] [Abstract][Full Text] [Related]  

  • 16. External quality assessment of Jordanian clinical chemistry laboratories.
    Bilto YY
    Ann Clin Biochem; 1992 May; 29 ( Pt 3)():324-30. PubMed ID: 1610107
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Evaluation of the Olympus AU 400 clinical chemistry analyzer.
    Bilić A; Alpeza I; Rukavina AS
    Clin Lab; 2000; 46(1-2):1-6. PubMed ID: 10745974
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Bias in analytical chemistry: A review of selected procedures for incorporating uncorrected bias into the expanded uncertainty of analytical measurements and a graphical method for evaluating the concordance of reference and test procedures.
    Frenkel R; Farrance I; Badrick T
    Clin Chim Acta; 2019 Aug; 495():129-138. PubMed ID: 30935874
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Metrological traceability of values for catalytic concentration of enzymes assigned to a calibration material.
    Canalias F; Camprubí S; Sánchez M; Gella FJ
    Clin Chem Lab Med; 2006; 44(3):333-9. PubMed ID: 16519608
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Essential criteria for quality systems in medical laboratories.
    Jansen RT; Blaton V; Burnett D; Huisman W; Queraltó JM; Zérah S; Allman B
    Eur J Clin Chem Clin Biochem; 1997 Feb; 35(2):121-2. PubMed ID: 9056756
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 15.