These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

187 related articles for article (PubMed ID: 12059082)

  • 1. Comparison of quick and owren prothrombin time with regard to the harmonisation of the International Normalised Ratio (INR) system.
    Horsti J
    Clin Chem Lab Med; 2002 Apr; 40(4):399-403. PubMed ID: 12059082
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Has the Quick or the Owren prothrombin time method the advantage in harmonization for the International Normalized Ratio system?
    Horsti J
    Blood Coagul Fibrinolysis; 2002 Oct; 13(7):641-6. PubMed ID: 12439151
    [TBL] [Abstract][Full Text] [Related]  

  • 3. INR calibration of Owren-type prothrombin time based on the relationship between PT% and INR utilizing normal plasma samples.
    Lindahl TL; Egberg N; Hillarp A; Ødegaard OR; Edlund B; Svensson J; Sandset PM; Rånby M
    Thromb Haemost; 2004 Jun; 91(6):1223-31. PubMed ID: 15175811
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Comparison between CoaguChek S- and Owren-type prothrombin time assay for monitoring anticoagulant therapy.
    Jonsson M; Hillarp A; Svensson P
    Thromb Res; 2004; 114(2):83-9. PubMed ID: 15306149
    [TBL] [Abstract][Full Text] [Related]  

  • 5. The international normalized ratio according to Owren in liver disease: interlaboratory assessment and determination of international sensitivity index.
    Magnusson M; Sten-Linder M; Bergquist A; Rajani R; Kechagias S; Fischler B; Németh A; Lindahl TL
    Thromb Res; 2013 Sep; 132(3):346-51. PubMed ID: 23993902
    [TBL] [Abstract][Full Text] [Related]  

  • 6. [Accuracy and reliability of international normalized ratio (INR) in monitoring of warfarin--comparison in the sensitivity to extrinsic coagulation factors between PT (INR) and TT (INR)].
    Sakayori T; Naito S; Yoshida M; Kumano O; Kato N; Okuda M; Ieko M
    Rinsho Byori; 2010 Aug; 58(8):779-85. PubMed ID: 20860170
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Effect of melagatran on prothrombin time assays depends on the sensitivity of the thromboplastin and the final dilution of the plasma sample.
    Mattsson C; Menschiek-Lundin A; Wåhlander K; Lindahl TL
    Thromb Haemost; 2001 Aug; 86(2):611-5. PubMed ID: 11522011
    [TBL] [Abstract][Full Text] [Related]  

  • 8. [Biological monitoring of treatment with antivitamin K. Value of INR and definition of new therapeutic ranges. A study of 73 patients].
    Gouin I; Horellou MH; Conard J; Samama M
    Arch Mal Coeur Vaiss; 1990 Mar; 83(3):357-61. PubMed ID: 2108630
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Comparison and evaluation of a Point-of-care device (CoaguChek XS) to Owren-type prothrombin time assay for monitoring of oral anticoagulant therapy with warfarin.
    Wieloch M; Hillarp A; Strandberg K; Nilsson C; Svensson PJ
    Thromb Res; 2009 Jul; 124(3):344-8. PubMed ID: 19423152
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Use of EDTA samples for prothrombin time measurement in patients receiving oral anticoagulants.
    Horsti J
    Haematologica; 2001 Aug; 86(8):851-5. PubMed ID: 11522542
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Warfarin monitoring with viscoelastic haemostatic assays, thrombin generation, coagulation factors and correlations to Owren and Quick prothrombin time.
    Nilsson CU; Strandberg K; Reinstrup P
    Scand J Clin Lab Invest; 2018 Sep; 78(5):358-364. PubMed ID: 29792060
    [TBL] [Abstract][Full Text] [Related]  

  • 12. A modified method of prothrombin time/International Normalised Ratio determination in capillary blood and monitoring oral anticoagulant therapy.
    Berkovsky A; Sergeeva EV; Suvorov AV; Uljavova IS; Kachalova ND; Klimovich LG; Samsonova NN; Kozlov AA
    Clin Chem Lab Med; 2006; 44(10):1214-7. PubMed ID: 17032133
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Discrepant sensitivity of thromboplastin reagents to clotting factor levels explored by the prothrombin time in patients on stable oral anticoagulant treatment: impact on the international normalized ratio system.
    Testa S; Morstabilini G; Fattorini A; Galli L; Denti N; D'Angelo A
    Haematologica; 2002 Dec; 87(12):1265-73. PubMed ID: 12495900
    [TBL] [Abstract][Full Text] [Related]  

  • 14. The Quick and Owren prothrombin time methods for oral anticoagulant therapy do not agree well using the International Normalized Ratio (INR) units.
    Horsti J
    Scand J Clin Lab Invest; 2003; 63(6):455-6. PubMed ID: 14594327
    [No Abstract]   [Full Text] [Related]  

  • 15. Mathematical derivative applied to international normalised ratio and analytical variations in oral anticoagulant therapy control.
    Introcaso G; Cuboni A; Ratto A; Foieni F
    Haemostasis; 2000; 30(6):281-9. PubMed ID: 11356996
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Local INR calibration of the Owren type prothrombin assay greatly improves the intra- and interlaboratory variation. A three-year follow-up from the Swedish national external quality assessment scheme.
    Hillarp A; Egberg N; Nordin G; Stigendal L; Fagerberg I; Lindahl TL
    Thromb Haemost; 2004 Feb; 91(2):300-7. PubMed ID: 14961158
    [TBL] [Abstract][Full Text] [Related]  

  • 17. The significance of the International Normalized Ratio (INR) for oral anticoagulant therapy.
    van den Besselaar AM
    J Int Fed Clin Chem; 1991 Sep; 3(4):146-53. PubMed ID: 20821873
    [TBL] [Abstract][Full Text] [Related]  

  • 18. [Quality control of ISI/INR system in oral anticoagulant therapy].
    Kazama M
    Rinsho Ketsueki; 1990 Jun; 31(6):769-75. PubMed ID: 2214167
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Improving the harmonisation of the International Normalized Ratio (INR): time to think outside the box?
    Favaloro EJ; McVicker W; Hamdam S; Hocker N
    Clin Chem Lab Med; 2010 Aug; 48(8):1079-90. PubMed ID: 20441474
    [TBL] [Abstract][Full Text] [Related]  

  • 20. [The factors that influence the consistency of international normalized ratio of prothrombin time].
    Su W; Ren FQ
    Zhongguo Yi Xue Ke Xue Yuan Xue Bao; 2001 Apr; 23(2):196-8. PubMed ID: 12905903
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 10.