BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

204 related articles for article (PubMed ID: 12066121)

  • 41. The efficacy of intrapartum fetal surveillance when fetal pulse oximetry is added to cardiotocography.
    van den Berg PP; Dildy GA; Luttkus A; Mason GC; Harvey CJ; Nijhuis JG; Jongsma HW
    Eur J Obstet Gynecol Reprod Biol; 1997 Mar; 72 Suppl():S67-71. PubMed ID: 9134416
    [TBL] [Abstract][Full Text] [Related]  

  • 42. [Fetal pulse oximetry. Intrapartum foetal hypoxia evaluation. Comparative study with invasive techniques concerning foetal welfare].
    Fernández Andrés I; Martínez Montero I
    An Sist Sanit Navar; 2004; 27(2):179-89. PubMed ID: 15381950
    [TBL] [Abstract][Full Text] [Related]  

  • 43. Meconium-stained amniotic fluid and fetal oxygen saturation measured by pulse oximetry during labour.
    Grignaffini A; Soncini E; Ronzoni E; Piazza E; Anfuso S; Vadora E
    Acta Biomed; 2004; 75 Suppl 1():45-52. PubMed ID: 15301290
    [TBL] [Abstract][Full Text] [Related]  

  • 44. Fetal pulse oximetry and visual on-line signal identification in the second stage of labor.
    Haeusler MC; Arikan G; Haas J; Kainer F
    Am J Obstet Gynecol; 1996 Oct; 175(4 Pt 1):1071-4. PubMed ID: 8885778
    [TBL] [Abstract][Full Text] [Related]  

  • 45. Accuracy of fetal pulse oximetry.
    Luttkus AK; Lübke M; Büscher U; Porath M; Dudenhausen JW
    Acta Obstet Gynecol Scand; 2002 May; 81(5):417-23. PubMed ID: 12027815
    [TBL] [Abstract][Full Text] [Related]  

  • 46. Fetal pulse oximetry and wavelet analysis of the fetal heart rate in the evaluation of abnormal cardiotocography tracings.
    Salamalekis E; Siristatidis C; Vasios G; Saloum J; Giannaris D; Chrelias C; Prentza A; Koutsouris D
    J Obstet Gynaecol Res; 2006 Apr; 32(2):135-9. PubMed ID: 16594915
    [TBL] [Abstract][Full Text] [Related]  

  • 47. The prediction of fetal acidosis at birth by computerised analysis of intrapartum cardiotocography.
    Chung TK; Mohajer MP; Yang ZJ; Chang AM; Sahota DS
    Br J Obstet Gynaecol; 1995 Jun; 102(6):454-60. PubMed ID: 7632636
    [TBL] [Abstract][Full Text] [Related]  

  • 48. Predictive value of fetal scalp pH and base excess for fetal acidosis and poor neonatal outcome.
    Tsikouras P; Koukouli Z; Niesigk B; Manav B; Farmakides G; Csorba R; Galazios G; Teichmann AT
    J Matern Fetal Neonatal Med; 2018 Dec; 31(23):3166-3171. PubMed ID: 28782450
    [TBL] [Abstract][Full Text] [Related]  

  • 49. [Fetal reflectance pulse oximetry sub partu. Experiences--prognostic significance and consequences--goals].
    Seelbach-Göbel B; Butterwegge M; Kühnert M; Heupel M
    Z Geburtshilfe Perinatol; 1994; 198(2):67-71. PubMed ID: 8023534
    [TBL] [Abstract][Full Text] [Related]  

  • 50. Reusable sensors in intrapartum foetal reflection pulse oximetry.
    Arikan MG; Haas J; Giuliani A; Haeusler M
    Biosens Bioelectron; 2002 Jun; 17(6-7):457-62. PubMed ID: 11959465
    [TBL] [Abstract][Full Text] [Related]  

  • 51. Calibration of a reflectance pulse oximeter in fetal lambs for arterial oxygen saturations below 70%.
    Carter AM; Stiller R; König V; Jørgensen JS; Svendsen P; Huch R
    J Soc Gynecol Investig; 1998; 5(5):255-9. PubMed ID: 9773401
    [TBL] [Abstract][Full Text] [Related]  

  • 52. Abnormal fetal heart rate patterns during the active phase of labor: the value of fetal oxygen saturation.
    Vitoratos N; Salamalekis E; Saloum J; Makrakis E; Creatsas G
    J Matern Fetal Neonatal Med; 2002 Jan; 11(1):46-9. PubMed ID: 12380608
    [TBL] [Abstract][Full Text] [Related]  

  • 53. Evaluation of fetal intrapartum hypoxia by middle cerebral and umbilical artery Doppler velocimetry with simultaneous cardiotocography and pulse oximetry.
    Siristatidis C; Salamalekis E; Kassanos D; Loghis C; Creatsas G
    Arch Gynecol Obstet; 2004 Dec; 270(4):265-70. PubMed ID: 14600768
    [TBL] [Abstract][Full Text] [Related]  

  • 54. [Fetal pulse oxymetry].
    Eszto ML; Morel O; Deval B; Thiébaugeorges O
    Gynecol Obstet Fertil; 2007 Jun; 35(6):576-81. PubMed ID: 17544314
    [TBL] [Abstract][Full Text] [Related]  

  • 55. Assessment of fetal scalp oxygen saturation determination in the sheep by transmission pulse oximetry.
    Nijland MJ; Shankar U; Iyer V; Ross MG
    Am J Obstet Gynecol; 2000 Dec; 183(6):1549-53. PubMed ID: 11120526
    [TBL] [Abstract][Full Text] [Related]  

  • 56. [The management of labor overweight women with intrapartum fetal oxygen saturation monitoring].
    Skoczylas M; Zdziennicki A; Laudański T
    Ginekol Pol; 2001 Dec; 72(12):1189-93. PubMed ID: 11883234
    [TBL] [Abstract][Full Text] [Related]  

  • 57. The influence of maternal epidural analgesia upon intrapartum fetal oxygenation.
    Caracostea G; Stamatian F; Lerintiu M; Herghea D
    J Matern Fetal Neonatal Med; 2007 Feb; 20(2):161-5. PubMed ID: 17437215
    [TBL] [Abstract][Full Text] [Related]  

  • 58. Effect of location of the sensor on reflectance pulse oximetry.
    Dassel AC; Graaff R; Aardema M; Zijlstra WG; Aarnoudse JG
    Br J Obstet Gynaecol; 1997 Aug; 104(8):910-6. PubMed ID: 9255082
    [TBL] [Abstract][Full Text] [Related]  

  • 59. Continuous monitoring of fetal oxygen saturation by pulse oximetry.
    Luttkus A; Fengler TW; Friedmann W; Dudenhausen JW
    Obstet Gynecol; 1995 Feb; 85(2):183-6. PubMed ID: 7529914
    [TBL] [Abstract][Full Text] [Related]  

  • 60. Sensitivity and specificity of intrapartum computerised FIGO criteria for cardiotocography and fetal scalp pH during labour: multicentre, observational study.
    Schiermeier S; Pildner von Steinburg S; Thieme A; Reinhard J; Daumer M; Scholz M; Hatzmann W; Schneider KT
    BJOG; 2008 Nov; 115(12):1557-63. PubMed ID: 18752587
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 11.