204 related articles for article (PubMed ID: 12066121)
41. The efficacy of intrapartum fetal surveillance when fetal pulse oximetry is added to cardiotocography.
van den Berg PP; Dildy GA; Luttkus A; Mason GC; Harvey CJ; Nijhuis JG; Jongsma HW
Eur J Obstet Gynecol Reprod Biol; 1997 Mar; 72 Suppl():S67-71. PubMed ID: 9134416
[TBL] [Abstract][Full Text] [Related]
42. [Fetal pulse oximetry. Intrapartum foetal hypoxia evaluation. Comparative study with invasive techniques concerning foetal welfare].
Fernández Andrés I; Martínez Montero I
An Sist Sanit Navar; 2004; 27(2):179-89. PubMed ID: 15381950
[TBL] [Abstract][Full Text] [Related]
43. Meconium-stained amniotic fluid and fetal oxygen saturation measured by pulse oximetry during labour.
Grignaffini A; Soncini E; Ronzoni E; Piazza E; Anfuso S; Vadora E
Acta Biomed; 2004; 75 Suppl 1():45-52. PubMed ID: 15301290
[TBL] [Abstract][Full Text] [Related]
44. Fetal pulse oximetry and visual on-line signal identification in the second stage of labor.
Haeusler MC; Arikan G; Haas J; Kainer F
Am J Obstet Gynecol; 1996 Oct; 175(4 Pt 1):1071-4. PubMed ID: 8885778
[TBL] [Abstract][Full Text] [Related]
45. Accuracy of fetal pulse oximetry.
Luttkus AK; Lübke M; Büscher U; Porath M; Dudenhausen JW
Acta Obstet Gynecol Scand; 2002 May; 81(5):417-23. PubMed ID: 12027815
[TBL] [Abstract][Full Text] [Related]
46. Fetal pulse oximetry and wavelet analysis of the fetal heart rate in the evaluation of abnormal cardiotocography tracings.
Salamalekis E; Siristatidis C; Vasios G; Saloum J; Giannaris D; Chrelias C; Prentza A; Koutsouris D
J Obstet Gynaecol Res; 2006 Apr; 32(2):135-9. PubMed ID: 16594915
[TBL] [Abstract][Full Text] [Related]
47. The prediction of fetal acidosis at birth by computerised analysis of intrapartum cardiotocography.
Chung TK; Mohajer MP; Yang ZJ; Chang AM; Sahota DS
Br J Obstet Gynaecol; 1995 Jun; 102(6):454-60. PubMed ID: 7632636
[TBL] [Abstract][Full Text] [Related]
48. Predictive value of fetal scalp pH and base excess for fetal acidosis and poor neonatal outcome.
Tsikouras P; Koukouli Z; Niesigk B; Manav B; Farmakides G; Csorba R; Galazios G; Teichmann AT
J Matern Fetal Neonatal Med; 2018 Dec; 31(23):3166-3171. PubMed ID: 28782450
[TBL] [Abstract][Full Text] [Related]
49. [Fetal reflectance pulse oximetry sub partu. Experiences--prognostic significance and consequences--goals].
Seelbach-Göbel B; Butterwegge M; Kühnert M; Heupel M
Z Geburtshilfe Perinatol; 1994; 198(2):67-71. PubMed ID: 8023534
[TBL] [Abstract][Full Text] [Related]
50. Reusable sensors in intrapartum foetal reflection pulse oximetry.
Arikan MG; Haas J; Giuliani A; Haeusler M
Biosens Bioelectron; 2002 Jun; 17(6-7):457-62. PubMed ID: 11959465
[TBL] [Abstract][Full Text] [Related]
51. Calibration of a reflectance pulse oximeter in fetal lambs for arterial oxygen saturations below 70%.
Carter AM; Stiller R; König V; Jørgensen JS; Svendsen P; Huch R
J Soc Gynecol Investig; 1998; 5(5):255-9. PubMed ID: 9773401
[TBL] [Abstract][Full Text] [Related]
52. Abnormal fetal heart rate patterns during the active phase of labor: the value of fetal oxygen saturation.
Vitoratos N; Salamalekis E; Saloum J; Makrakis E; Creatsas G
J Matern Fetal Neonatal Med; 2002 Jan; 11(1):46-9. PubMed ID: 12380608
[TBL] [Abstract][Full Text] [Related]
53. Evaluation of fetal intrapartum hypoxia by middle cerebral and umbilical artery Doppler velocimetry with simultaneous cardiotocography and pulse oximetry.
Siristatidis C; Salamalekis E; Kassanos D; Loghis C; Creatsas G
Arch Gynecol Obstet; 2004 Dec; 270(4):265-70. PubMed ID: 14600768
[TBL] [Abstract][Full Text] [Related]
54. [Fetal pulse oxymetry].
Eszto ML; Morel O; Deval B; Thiébaugeorges O
Gynecol Obstet Fertil; 2007 Jun; 35(6):576-81. PubMed ID: 17544314
[TBL] [Abstract][Full Text] [Related]
55. Assessment of fetal scalp oxygen saturation determination in the sheep by transmission pulse oximetry.
Nijland MJ; Shankar U; Iyer V; Ross MG
Am J Obstet Gynecol; 2000 Dec; 183(6):1549-53. PubMed ID: 11120526
[TBL] [Abstract][Full Text] [Related]
56. [The management of labor overweight women with intrapartum fetal oxygen saturation monitoring].
Skoczylas M; Zdziennicki A; Laudański T
Ginekol Pol; 2001 Dec; 72(12):1189-93. PubMed ID: 11883234
[TBL] [Abstract][Full Text] [Related]
57. The influence of maternal epidural analgesia upon intrapartum fetal oxygenation.
Caracostea G; Stamatian F; Lerintiu M; Herghea D
J Matern Fetal Neonatal Med; 2007 Feb; 20(2):161-5. PubMed ID: 17437215
[TBL] [Abstract][Full Text] [Related]
58. Effect of location of the sensor on reflectance pulse oximetry.
Dassel AC; Graaff R; Aardema M; Zijlstra WG; Aarnoudse JG
Br J Obstet Gynaecol; 1997 Aug; 104(8):910-6. PubMed ID: 9255082
[TBL] [Abstract][Full Text] [Related]
59. Continuous monitoring of fetal oxygen saturation by pulse oximetry.
Luttkus A; Fengler TW; Friedmann W; Dudenhausen JW
Obstet Gynecol; 1995 Feb; 85(2):183-6. PubMed ID: 7529914
[TBL] [Abstract][Full Text] [Related]
60. Sensitivity and specificity of intrapartum computerised FIGO criteria for cardiotocography and fetal scalp pH during labour: multicentre, observational study.
Schiermeier S; Pildner von Steinburg S; Thieme A; Reinhard J; Daumer M; Scholz M; Hatzmann W; Schneider KT
BJOG; 2008 Nov; 115(12):1557-63. PubMed ID: 18752587
[TBL] [Abstract][Full Text] [Related]
[Previous] [Next] [New Search]