178 related articles for article (PubMed ID: 12066705)
1. A method aimed at achieving passive fit in implant prostheses: case report.
Iglesia MA; Moreno J
Int J Prosthodont; 2001; 14(6):570-4. PubMed ID: 12066705
[TBL] [Abstract][Full Text] [Related]
2. Repairing an implant titanium milled framework using laser welding technology: a clinical report.
Prasad S; Monaco EA
J Prosthet Dent; 2009 Apr; 101(4):221-5. PubMed ID: 19328274
[TBL] [Abstract][Full Text] [Related]
3. Custom-made laser-welded titanium implant prosthetic abutment.
Iglesia-Puig MA
J Prosthet Dent; 2005 Oct; 94(4):401-3. PubMed ID: 16198181
[TBL] [Abstract][Full Text] [Related]
4. Influence of different tightening forces before laser welding to the implant/framework fit.
da Silveira-Júnior CD; Neves FD; Fernandes-Neto AJ; Prado CJ; Simamoto-Júnior PC
J Prosthodont; 2009 Jun; 18(4):337-41. PubMed ID: 19210612
[TBL] [Abstract][Full Text] [Related]
5. Description and evaluation of a simplified method to achieve passive fit between cast titanium frameworks and implants.
Helldén LB; Dérand T
Int J Oral Maxillofac Implants; 1998; 13(2):190-6. PubMed ID: 9581404
[TBL] [Abstract][Full Text] [Related]
6. Implant-supported laser-welded titanium and conventional cast frameworks in the partially edentulous law: a 5-year prospective multicenter study.
Jemt T; Henry P; Lindén B; Naert I; Weber H; Wendelhag I
Int J Prosthodont; 2003; 16(4):415-21. PubMed ID: 12956498
[TBL] [Abstract][Full Text] [Related]
7. Comparisons of precision of fit between cast and CNC-milled titanium implant frameworks for the edentulous mandible.
Ortorp A; Jemt T; Bäck T; Jälevik T
Int J Prosthodont; 2003; 16(2):194-200. PubMed ID: 12737254
[TBL] [Abstract][Full Text] [Related]
8. The use of laser-welded titanium framework technology: a case report for the totally edentulous patient.
Jackson BJ
J Oral Implantol; 2005; 31(6):294-300. PubMed ID: 16447902
[TBL] [Abstract][Full Text] [Related]
9. Implant overdenture using Konus telescope on one-piece implant: a case report.
Ohkubo C; Kobayashi M; Okamoto N; Hosoi T; Kurtz KS; Murata T
Eur J Prosthodont Restor Dent; 2009 Dec; 17(4):188-91. PubMed ID: 20158062
[TBL] [Abstract][Full Text] [Related]
10. Syncrystallization: a technique for temporization of immediately loaded implants with metal-reinforced acrylic resin restorations.
Degidi M; Gehrke P; Spanel A; Piattelli A
Clin Implant Dent Relat Res; 2006; 8(3):123-34. PubMed ID: 16919020
[TBL] [Abstract][Full Text] [Related]
11. Evaluation of a new method to achieve optimal passivity of implant-supported superstructures.
Goossens IC; Herbst D
SADJ; 2003 Aug; 58(7):279-85, 287. PubMed ID: 14649041
[TBL] [Abstract][Full Text] [Related]
12. Tooth- and implant-supported prostheses: a retrospective clinical follow-up up to 8 years.
Kindberg H; Gunne J; Kronström M
Int J Prosthodont; 2001; 14(6):575-81. PubMed ID: 12066706
[TBL] [Abstract][Full Text] [Related]
13. Comparative analysis of the fit of 3-unit implant-supported frameworks cast in nickel-chromium and cobalt-chromium alloys and commercially pure titanium after casting, laser welding, and simulated porcelain firings.
Tiossi R; Rodrigues RC; de Mattos Mda G; Ribeiro RF
Int J Prosthodont; 2008; 21(2):121-3. PubMed ID: 18546764
[TBL] [Abstract][Full Text] [Related]
14. Comparison of interface relationships between implant components for laser-welded titanium frameworks and standard cast frameworks.
Rubenstein JE; Ma T
Int J Oral Maxillofac Implants; 1999; 14(4):491-5. PubMed ID: 10453662
[TBL] [Abstract][Full Text] [Related]
15. Structure and mechanical properties of Cresco-Ti laser-welded joints and stress analyses using finite element models of fixed distal extension and fixed partial prosthetic designs.
Uysal H; Kurtoglu C; Gurbuz R; Tutuncu N
J Prosthet Dent; 2005 Mar; 93(3):235-44. PubMed ID: 15775924
[TBL] [Abstract][Full Text] [Related]
16. On titanium frameworks and alternative impression techniques in implant dentistry.
Ortorp A
Swed Dent J Suppl; 2005; (169):3-88. PubMed ID: 15709359
[TBL] [Abstract][Full Text] [Related]
17. A simplified method to assess precision of fit between framework and supporting implants: a preliminary study.
Calderini A; Maiorana C; Garlini G; Abbondanza T
Int J Oral Maxillofac Implants; 2007; 22(5):831-8. PubMed ID: 17974120
[TBL] [Abstract][Full Text] [Related]
18. An alternative section method for casting and posterior laser welding of metallic frameworks for an implant-supported prosthesis.
de Aguiar FA; Tiossi R; Rodrigues RC; Mattos Mde G; Ribeiro RF
J Prosthodont; 2009 Apr; 18(3):230-4. PubMed ID: 19141050
[TBL] [Abstract][Full Text] [Related]
19. Fixed implant-supported prostheses with welded titanium frameworks.
Jemt T; Lindén B
Int J Periodontics Restorative Dent; 1992; 12(3):177-84. PubMed ID: 1363939
[TBL] [Abstract][Full Text] [Related]
20. Passive fit of frameworks in titanium and palladium-silver alloy submitted the laser welding.
de Sousa SA; de Arruda Nobilo MA; Henriques GE; Mesquita MF
J Oral Rehabil; 2008 Feb; 35(2):123-7. PubMed ID: 18197845
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]