164 related articles for article (PubMed ID: 12069086)
1. A Monte Carlo dose calculation tool for radiotherapy treatment planning.
Ma CM; Li JS; Pawlicki T; Jiang SB; Deng J; Lee MC; Koumrian T; Luxton M; Brain S
Phys Med Biol; 2002 May; 47(10):1671-89. PubMed ID: 12069086
[TBL] [Abstract][Full Text] [Related]
2. Validation of a Monte Carlo dose calculation tool for radiotherapy treatment planning.
Li JS; Pawlicki T; Deng J; Jiang SB; Mok E; Ma CM
Phys Med Biol; 2000 Oct; 45(10):2969-85. PubMed ID: 11049183
[TBL] [Abstract][Full Text] [Related]
3. Monte Carlo simulation and dosimetric verification of radiotherapy beam modifiers.
Spezi E; Lewis DG; Smith CW
Phys Med Biol; 2001 Nov; 46(11):3007-29. PubMed ID: 11720360
[TBL] [Abstract][Full Text] [Related]
4. Clinical implementation of a Monte Carlo treatment planning system.
Ma CM; Mok E; Kapur A; Pawlicki T; Findley D; Brain S; Forster K; Boyer AL
Med Phys; 1999 Oct; 26(10):2133-43. PubMed ID: 10535630
[TBL] [Abstract][Full Text] [Related]
5. Determination of the initial beam parameters in Monte Carlo linac simulation.
Aljarrah K; Sharp GC; Neicu T; Jiang SB
Med Phys; 2006 Apr; 33(4):850-8. PubMed ID: 16696460
[TBL] [Abstract][Full Text] [Related]
6. Validation of the Swiss Monte Carlo Plan for a static and dynamic 6 MV photon beam.
Magaddino V; Manser P; Frei D; Volken W; Schmidhalter D; Hirschi L; Fix MK
Z Med Phys; 2011 May; 21(2):124-34. PubMed ID: 21239148
[TBL] [Abstract][Full Text] [Related]
7. Dose verification of an IMRT treatment planning system with the BEAM EGS4-based Monte Carlo code.
Francescon P; Cora S; Chiovati P
Med Phys; 2003 Feb; 30(2):144-57. PubMed ID: 12607832
[TBL] [Abstract][Full Text] [Related]
8. Accuracy of patient dose calculation for lung IMRT: A comparison of Monte Carlo, convolution/superposition, and pencil beam computations.
Vanderstraeten B; Reynaert N; Paelinck L; Madani I; De Wagter C; De Gersem W; De Neve W; Thierens H
Med Phys; 2006 Sep; 33(9):3149-58. PubMed ID: 17022207
[TBL] [Abstract][Full Text] [Related]
9. A practical Monte Carlo MU verification tool for IMRT quality assurance.
Fan J; Li J; Chen L; Stathakis S; Luo W; Du Plessis F; Xiong W; Yang J; Ma CM
Phys Med Biol; 2006 May; 51(10):2503-15. PubMed ID: 16675866
[TBL] [Abstract][Full Text] [Related]
10. Intensity modulated irradiation of a thorax phantom: comparisons between measurements, Monte Carlo calculations and pencil beam calculations.
Laub WU; Bakai A; Nüsslin F
Phys Med Biol; 2001 Jun; 46(6):1695-706. PubMed ID: 11419628
[TBL] [Abstract][Full Text] [Related]
11. Development and commissioning of a Monte Carlo photon beam model for the forthcoming clinical trials in microbeam radiation therapy.
Martínez-Rovira I; Sempau J; Prezado Y
Med Phys; 2012 Jan; 39(1):119-31. PubMed ID: 22225281
[TBL] [Abstract][Full Text] [Related]
12. Total skin electron therapy treatment verification: Monte Carlo simulation and beam characteristics of large non-standard electron fields.
Pavón EC; Sánchez-Doblado F; Leal A; Capote R; Lagares JI; Perucha M; Arráns R
Phys Med Biol; 2003 Sep; 48(17):2783-96. PubMed ID: 14516101
[TBL] [Abstract][Full Text] [Related]
13. An efficient framework for photon Monte Carlo treatment planning.
Fix MK; Manser P; Frei D; Volken W; Mini R; Born EJ
Phys Med Biol; 2007 Oct; 52(19):N425-37. PubMed ID: 17881793
[TBL] [Abstract][Full Text] [Related]
14. Moving GPU-OpenCL-based Monte Carlo dose calculation toward clinical use: Automatic beam commissioning and source sampling for treatment plan dose calculation.
Tian Z; Li Y; Hassan-Rezaeian N; Jiang SB; Jia X
J Appl Clin Med Phys; 2017 Mar; 18(2):69-84. PubMed ID: 28300376
[TBL] [Abstract][Full Text] [Related]
15. Dose calculation accuracy of lung planning with a commercial IMRT treatment planning system.
McDermott PN; He T; DeYoung A
J Appl Clin Med Phys; 2003; 4(4):341-51. PubMed ID: 14604424
[TBL] [Abstract][Full Text] [Related]
16. Comparison of dose calculation algorithms with Monte Carlo methods for photon arcs.
Chow JC; Wong E; Chen JZ; Van Dyk J
Med Phys; 2003 Oct; 30(10):2686-94. PubMed ID: 14596305
[TBL] [Abstract][Full Text] [Related]
17. Retrospective monte carlo dose calculations with limited beam weight information.
Lindsay PE; El Naqa I; Hope AJ; Vicic M; Cui J; Bradley JD; Deasy JO
Med Phys; 2007 Jan; 34(1):334-46. PubMed ID: 17278519
[TBL] [Abstract][Full Text] [Related]
18. Quantitative assessment of the accuracy of dose calculation using pencil beam and Monte Carlo algorithms and requirements for clinical quality assurance.
Ali I; Ahmad S
Med Dosim; 2013; 38(3):255-61. PubMed ID: 23558145
[TBL] [Abstract][Full Text] [Related]
19. Implementation of random set-up errors in Monte Carlo calculated dynamic IMRT treatment plans.
Stapleton S; Zavgorodni S; Popescu IA; Beckham WA
Phys Med Biol; 2005 Feb; 50(3):429-39. PubMed ID: 15773721
[TBL] [Abstract][Full Text] [Related]
20. Photon dose calculation of a three-dimensional treatment planning system compared to the Monte Carlo code BEAM.
Francescon P; Cavedon C; Reccanello S; Cora S
Med Phys; 2000 Jul; 27(7):1579-87. PubMed ID: 10947261
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]