BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

129 related articles for article (PubMed ID: 12081448)

  • 21. HYSCORE and DEER with an upgraded 95GHz pulse EPR spectrometer.
    Goldfarb D; Lipkin Y; Potapov A; Gorodetsky Y; Epel B; Raitsimring AM; Radoul M; Kaminker I
    J Magn Reson; 2008 Sep; 194(1):8-15. PubMed ID: 18571956
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Detection of electron paramagnetic resonance absorption using frequency modulation.
    Hirata H; Kuyama T; Ono M; Shimoyama Y
    J Magn Reson; 2003 Oct; 164(2):233-41. PubMed ID: 14511592
    [TBL] [Abstract][Full Text] [Related]  

  • 23. A rectangular loop-gap resonator for EPR studies of aqueous samples.
    Piasecki W; Froncisz W; Hubbell WL
    J Magn Reson; 1998 Sep; 134(1):36-43. PubMed ID: 9740728
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Magic-angle sample spinning electron paramagnetic resonance--instrumentation, performance, and limitations.
    Hessinger D; Bauer C; Hubrich M; Jeschke G; Spiess HW
    J Magn Reson; 2000 Dec; 147(2):217-25. PubMed ID: 11097812
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Uniform Field Resonators for EPR Spectroscopy: A Review.
    Hyde JS; Sidabras JW; Mett RR
    Cell Biochem Biophys; 2019 Mar; 77(1):3-14. PubMed ID: 29943362
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Uniform field loop-gap resonator and rectangular TE
    Sidabras JW; Sarna T; Mett RR; Hyde JS
    J Magn Reson; 2017 Sep; 282():129-135. PubMed ID: 28803092
    [TBL] [Abstract][Full Text] [Related]  

  • 27. W-band frequency-swept EPR.
    Hyde JS; Strangeway RA; Camenisch TG; Ratke JJ; Froncisz W
    J Magn Reson; 2010 Jul; 205(1):93-101. PubMed ID: 20462775
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Digital EPR with an arbitrary waveform generator and direct detection at the carrier frequency.
    Tseitlin M; Quine RW; Rinard GA; Eaton SS; Eaton GR
    J Magn Reson; 2011 Dec; 213(1):119-25. PubMed ID: 21968420
    [TBL] [Abstract][Full Text] [Related]  

  • 29. A 750-MHz Electronically Tunable Resonator Using Microstrip Line Couplers for Electron Paramagnetic Resonance Imaging of a Mouse Tumor-Bearing Leg.
    Amida T; Nakaoka R; Komarov DA; Yamamoto K; Inanami O; Matsumoto S; Hirata H
    IEEE Trans Biomed Eng; 2018 May; 65(5):1124-1132. PubMed ID: 28841547
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Development of a resonator with automatic tuning and coupling capability to minimize sample motion noise for in vivo EPR spectroscopy.
    He G; Petryakov S; Samouilov A; Chzhan M; Kuppusamy P; Zweier JL
    J Magn Reson; 2001 Apr; 149(2):218-27. PubMed ID: 11318620
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Orthogonal resonators for pulse in vivo electron paramagnetic imaging at 250 MHz.
    Sundramoorthy SV; Epel B; Halpern HJ
    J Magn Reson; 2014 Mar; 240():45-51. PubMed ID: 24530507
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Multiquantum EPR spectroscopy of spin-labeled arrestin K267C at 35 GHz.
    Klug CS; Camenisch TG; Hubbell WL; Hyde JS
    Biophys J; 2005 May; 88(5):3641-7. PubMed ID: 15749769
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Double-stacked dielectric resonator for sensitive EPR measurements.
    Jaworski M; Sienkiewicz A; Scholes CP
    J Magn Reson; 1997 Jan; 124(1):87-96. PubMed ID: 9169212
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Triarylmethyl Radical: EPR Signal to Noise at Frequencies between 250 MHz and 1.5 GHz and Dependence of Relaxation on Radical and Salt Concentration and on Frequency.
    Shi Y; Quine RW; Rinard GA; Buchanan L; Eaton SS; Eaton GR; Epel B; Seagle SW; Halpern HJ
    Z Phys Chem (N F); 2017 Apr; 231(4):923-937. PubMed ID: 28392627
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Dielectric microwave resonators in TE(011) cavities for electron paramagnetic resonance spectroscopy.
    Mett RR; Sidabras JW; Golovina IS; Hyde JS
    Rev Sci Instrum; 2008 Sep; 79(9):094702. PubMed ID: 19044441
    [TBL] [Abstract][Full Text] [Related]  

  • 36. A tunable reentrant resonator with transverse orientation of electric field for in vivo EPR spectroscopy.
    Chzhan M; Kuppusamy P; Samouilov A; He G; Zweier JL
    J Magn Reson; 1999 Apr; 137(2):373-8. PubMed ID: 10089171
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Design and evaluation of a 1.1-GHz surface coil resonator for electron paramagnetic resonance-based tooth dosimetry.
    Sugawara H; Hirata H; Petryakov S; Lesniewski P; Williams BB; Flood AB; Swartz HM
    IEEE Trans Biomed Eng; 2014 Jun; 61(6):1894-901. PubMed ID: 24845300
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Rectangular loop-gap resonator with the light access to the sample.
    Dutka M; Oleś T; Mossakowski M; Froncisz W
    J Magn Reson; 2011 May; 210(1):44-50. PubMed ID: 21367631
    [TBL] [Abstract][Full Text] [Related]  

  • 39. New ceramic EPR resonators with high dielectric permittivity.
    Golovina I; Geifman I; Belous A
    J Magn Reson; 2008 Nov; 195(1):52-9. PubMed ID: 18815061
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Cryogenic Q-band (35GHz) probehead featuring large excitation microwave fields for pulse and continuous wave electron paramagnetic resonance spectroscopy: performance and applications.
    Forrer J; García-Rubio I; Schuhmam R; Tschaggelar R; Harmer J
    J Magn Reson; 2008 Feb; 190(2):280-91. PubMed ID: 18055237
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 7.