These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

163 related articles for article (PubMed ID: 12083298)

  • 1. Optimal resolution of superimposed action potentials.
    McGill KC
    IEEE Trans Biomed Eng; 2002 Jul; 49(7):640-50. PubMed ID: 12083298
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Resolving superimposed MUAPs using particle swarm optimization.
    Marateb HR; McGill KC
    IEEE Trans Biomed Eng; 2009 Mar; 56(3):916-9. PubMed ID: 19272923
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Noise reduction based on ICA decomposition and wavelet transform for the extraction of motor unit action potentials.
    Ren X; Yan Z; Wang Z; Hu X
    J Neurosci Methods; 2006 Dec; 158(2):313-22. PubMed ID: 16831466
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Estimation of motor unit conduction velocity from surface EMG recordings by signal-based selection of the spatial filters.
    Mesin L; Tizzani F; Farina D
    IEEE Trans Biomed Eng; 2006 Oct; 53(10):1963-71. PubMed ID: 17019860
    [TBL] [Abstract][Full Text] [Related]  

  • 5. A new method for the extraction and classification of single motor unit action potentials from surface EMG signals.
    Gazzoni M; Farina D; Merletti R
    J Neurosci Methods; 2004 Jul; 136(2):165-77. PubMed ID: 15183268
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Automatic decomposition of multichannel intramuscular EMG signals.
    Florestal JR; Mathieu PA; McGill KC
    J Electromyogr Kinesiol; 2009 Feb; 19(1):1-9. PubMed ID: 17513128
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Resolving superimposed motor unit action potentials.
    Etawil H; Stashuk D
    Med Biol Eng Comput; 1996 Jan; 34(1):33-40. PubMed ID: 8857310
    [TBL] [Abstract][Full Text] [Related]  

  • 8. A software package for the decomposition of long-term multichannel EMG signals using wavelet coefficients.
    Zennaro D; Wellig P; Koch VM; Moschytz GS; Läubli T
    IEEE Trans Biomed Eng; 2003 Jan; 50(1):58-69. PubMed ID: 12617525
    [TBL] [Abstract][Full Text] [Related]  

  • 9. A fast and reliable technique for muscle activity detection from surface EMG signals.
    Merlo A; Farina D; Merletti R
    IEEE Trans Biomed Eng; 2003 Mar; 50(3):316-23. PubMed ID: 12669988
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Formula-based approach of statistical tests for peri-stimulus time histograms.
    Ushiba J; Onishi Y; Tomita Y; Masakado Y
    IEEE Trans Biomed Eng; 2003 Nov; 50(11):1262-7. PubMed ID: 14619996
    [TBL] [Abstract][Full Text] [Related]  

  • 11. A control algorithm for autonomous optimization of extracellular recordings.
    Nenadic Z; Burdick JW
    IEEE Trans Biomed Eng; 2006 May; 53(5):941-55. PubMed ID: 16686417
    [TBL] [Abstract][Full Text] [Related]  

  • 12. A novel method for automated EMG decomposition and MUAP classification.
    Katsis CD; Goletsis Y; Likas A; Fotiadis DI; Sarmas I
    Artif Intell Med; 2006 May; 37(1):55-64. PubMed ID: 16377160
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Decomposition of surface EMG signals.
    De Luca CJ; Adam A; Wotiz R; Gilmore LD; Nawab SH
    J Neurophysiol; 2006 Sep; 96(3):1646-57. PubMed ID: 16899649
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Simulations of motor unit number estimation techniques.
    Major LA; Jones KE
    J Neural Eng; 2005 Jun; 2(2):17-34. PubMed ID: 15928409
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Location of innervation zone determined with multichannel surface electromyography using an optical flow technique.
    Ostlund N; Gerdle B; Stefan Karlsson J
    J Electromyogr Kinesiol; 2007 Oct; 17(5):549-55. PubMed ID: 16890457
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Novel ideas for fast muscle action potential simulations using the line source model.
    Hammarberg B; Stålberg E
    IEEE Trans Biomed Eng; 2004 Nov; 51(11):1888-97. PubMed ID: 15543667
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Rigorous performance assessment of the algorithms for resolving motor unit action potential superpositions.
    Shirzadi M; Marateb HR; McGill KC; Mañanas MA
    J Electromyogr Kinesiol; 2021 Feb; 56():102510. PubMed ID: 33341461
    [TBL] [Abstract][Full Text] [Related]  

  • 18. The application of independent component analysis to the multi-channel surface electromyographic signals for separation of motor unit action potential trains: part II-modelling interpretation.
    Nakamura H; Yoshida M; Kotani M; Akazawa K; Moritani T
    J Electromyogr Kinesiol; 2004 Aug; 14(4):433-41. PubMed ID: 15165593
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Robustness of neuroprosthetic decoding algorithms.
    Serruya M; Hatsopoulos N; Fellows M; Paninski L; Donoghue J
    Biol Cybern; 2003 Mar; 88(3):219-28. PubMed ID: 12647229
    [TBL] [Abstract][Full Text] [Related]  

  • 20. The application of independent component analysis to the multi-channel surface electromyographic signals for separation of motor unit action potential trains: part I-measuring techniques.
    Nakamura H; Yoshida M; Kotani M; Akazawa K; Moritani T
    J Electromyogr Kinesiol; 2004 Aug; 14(4):423-32. PubMed ID: 15165592
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.