These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

163 related articles for article (PubMed ID: 12098544)

  • 1. Experimental investigation of the tension band in fractures of the patella.
    Fortis AP; Milis Z; Kostopoulos V; Tsantzalis S; Kormas P; Tzinieris N; Boudouris T
    Injury; 2002 Jul; 33(6):489-93. PubMed ID: 12098544
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Biomechanical evaluation of the tension band wiring principle. A comparison between two different techniques for transverse patella fracture fixation.
    Zderic I; Stoffel K; Sommer C; Höntzsch D; Gueorguiev B
    Injury; 2017 Aug; 48(8):1749-1757. PubMed ID: 28622833
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Biomechanical cadaver testing of a fixed-angle plate in comparison to tension wiring and screw fixation in transverse patella fractures.
    Thelen S; Schneppendahl J; Jopen E; Eichler C; Koebke J; Schönau E; Hakimi M; Windolf J; Wild M
    Injury; 2012 Aug; 43(8):1290-5. PubMed ID: 22608600
    [TBL] [Abstract][Full Text] [Related]  

  • 4. A Biomechanical Study of an Alternative Internal Fixation Method for Transverse Patella Fractures.
    Han S; Li D; Zhang P; Yin X; Kou Y; Han N; Fu Z
    Orthopedics; 2018 Sep; 41(5):e643-e648. PubMed ID: 30011055
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Lateral rim variable angle locked plating versus tension band wiring of simple and complex patella fractures: a biomechanical study.
    Warner S; Sommer C; Zderic I; Woodburn W; Castle R; Penman J; Saura-Sanchez E; Helfet DL; Gueorguiev B; Stoffel K
    Arch Orthop Trauma Surg; 2024 May; 144(5):2131-2140. PubMed ID: 38520547
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Novel techniques demonstrate superior fixation of simple transverse patella fractures - A biomechanical study.
    Lenihan J; Ramos-Pascual S; Silvestros P; Beak P; Miles AW; Trompeter A
    Injury; 2020 Jun; 51(6):1288-1293. PubMed ID: 32276726
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Transverse patella fracture fixation: A cadaveric biomechanical comparison of cannulated screws and anterior tension band versus low-profile, multiplanar mesh plating.
    Garner MR; Homcha B; Cowman T; Goss M; Reid JS; Lewis GS
    Injury; 2024 Jun; 55(6):111574. PubMed ID: 38669892
    [TBL] [Abstract][Full Text] [Related]  

  • 8. The biomechanical evaluation of polyester as a tension band for the internal fixation of patellar fractures.
    McGreal G; Reidy D; Joy A; Mahalingam K; Cashman WF
    J Med Eng Technol; 1999; 23(2):53-6. PubMed ID: 10356674
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Comparison of cannulated screw with tension band wiring versus compressive cannulated locking bolt and nut device (CompresSURE) in patella fractures-a cadaveric biomechanical study.
    Domby B; Henderson E; Nayak A; Erdoğan M; Gutierrez S; Santoni BG; Sagi HC
    J Orthop Trauma; 2012 Dec; 26(12):678-83. PubMed ID: 22932750
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Evaluation of methods of internal fixation of transverse patella fractures: a biomechanical study.
    Burvant JG; Thomas KA; Alexander R; Harris MB
    J Orthop Trauma; 1994; 8(2):147-53. PubMed ID: 8207572
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Biomechanical comparison of fixation methods in transverse patella fractures.
    Scilaris TA; Grantham JL; Prayson MJ; Marshall MP; Hamilton JJ; Williams JL
    J Orthop Trauma; 1998; 12(5):356-9. PubMed ID: 9671189
    [TBL] [Abstract][Full Text] [Related]  

  • 12. A double button adjustable loop device is biomechanically equivalent to tension band wire in the fixation of transverse patellar fractures-A cadaveric study.
    Han F; Pearce CJ; Ng DQ; Ramruttun AK; Chong DY; Murphy D; Lim CT; Lee BC
    Injury; 2017 Feb; 48(2):270-276. PubMed ID: 27890337
    [TBL] [Abstract][Full Text] [Related]  

  • 13. A Locked Intraosseous Nail for Transverse Patellar Fractures: A Biomechanical Comparison with Tension Band Wiring Through Cannulated Screws.
    Nienhaus M; Zderic I; Wahl D; Gueorguiev B; Rommens PM
    J Bone Joint Surg Am; 2018 Jun; 100(12):e83. PubMed ID: 29916933
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Titanium mesh as a low-profile alternative for tension-band augmentation in patella fracture fixation: A biomechanical study.
    Dickens AJ; Salas C; Rise L; Murray-Krezan C; Taha MR; DeCoster TA; Gehlert RJ
    Injury; 2015; 46(6):1001-6. PubMed ID: 25769202
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Treatment of Patellar Lower Pole Fracture with Modified Titanium Cable Tension Band Plus Patellar Tibial Tunnel Steel "8" Reduction Band.
    Li J; Wang D; He Z; Shi H
    J Invest Surg; 2019 Sep; 32(6):566-570. PubMed ID: 29308925
    [No Abstract]   [Full Text] [Related]  

  • 16. Comparison of two tension-band fixation materials and techniques in transverse patella fractures: a biomechanical study.
    Rabalais RD; Burger E; Lu Y; Mansour A; Baratta RV
    Orthopedics; 2008 Feb; 31(2):128. PubMed ID: 19292214
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Biomechanical comparison of three tension band wiring techniques for transverse fracture of patella: Kirschner wires, cannulated screws, and ring pins.
    Lee KH; Lee Y; Lee YH; Cho BW; Kim MB; Baek GH
    J Orthop Surg (Hong Kong); 2019; 27(3):2309499019882140. PubMed ID: 31711358
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Biomechanical Comparison of Tension Band Fixation of Patella Transverse Fracture: Headless Screws Versus Headed Screws.
    Martin JM; Applin DT; McGrady LM; Wang M; Schmeling GJ
    J Orthop Trauma; 2019 Jun; 33(6):e240-e245. PubMed ID: 30720558
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Where should Kirschner wires be placed when fixing patella fracture with modified tension-band wiring? A finite element analysis.
    Ling M; Zhan S; Jiang D; Hu H; Zhang C
    J Orthop Surg Res; 2019 Jan; 14(1):14. PubMed ID: 30634995
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Biomechanical comparison of a new staple technique with tension band wiring for transverse patella fractures.
    Schnabel B; Scharf M; Schwieger K; Windolf M; Pol Bv; Braunstein V; Appelt A
    Clin Biomech (Bristol, Avon); 2009 Dec; 24(10):855-9. PubMed ID: 19716216
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.