These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

149 related articles for article (PubMed ID: 12102355)

  • 21. Development of Monte Carlo based real-time treatment planning system with fast calculation algorithm for boron neutron capture therapy.
    Takada K; Kumada H; Liem PH; Sakurai H; Sakae T
    Phys Med; 2016 Dec; 32(12):1846-1851. PubMed ID: 27889131
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Shielding design studies for a neutron irradiator system based on a 252Cf source.
    da Silva AX; Crispim VR
    Radiat Prot Dosimetry; 2001; 95(4):333-8. PubMed ID: 11707031
    [TBL] [Abstract][Full Text] [Related]  

  • 23. On the production of neutrons in laminated barriers for 10 MV medical accelerator rooms.
    Facure A; da Silva AX; da Rosa LA; Cardoso SC; Rezende GF
    Med Phys; 2008 Jul; 35(7):3285-92. PubMed ID: 18697553
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Dosimetric effects of beam size and collimation of epithermal neutrons for boron neutron capture therapy.
    Yanch JC; Harling OK
    Radiat Res; 1993 Aug; 135(2):131-45. PubMed ID: 8367586
    [TBL] [Abstract][Full Text] [Related]  

  • 25. CHARACTERISATION OF THE GRAPHITE MODERATED THERMAL NEUTRON FIELD AT CMI.
    Vykydal Z; Králík M
    Radiat Prot Dosimetry; 2018 Aug; 180(1-4):51-55. PubMed ID: 29036348
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Characterisation of the TAPIRO BNCT epithermal facility.
    Burn KW; Colli V; Curzio G; d'Errico F; Gambarini G; Rosi G; Scolari L
    Radiat Prot Dosimetry; 2004; 110(1-4):645-9. PubMed ID: 15353724
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Dimethyl sulfoxide protects against thermal and epithermal neutron-induced cell death and mutagenesis of Chinese hamster ovary (CHO) cells.
    Kinashi Y; Sakurai Y; Masunaga S; Suzuki M; Akaboshi M; Ono K
    Int J Radiat Oncol Biol Phys; 2000 Jul; 47(5):1371-8. PubMed ID: 10889392
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Neutron production in tissue-like media and shielding materials irradiated with high-energy ion beams.
    Gudowska I; Kopec M; Sobolevsky N
    Radiat Prot Dosimetry; 2007; 126(1-4):652-6. PubMed ID: 17504751
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Assessment of the neutron radiation field with activation foils and intermittent irradiations around a PETtrace biomedical cyclotron.
    Benavente-Castillo JA; Lacerda MAS; Ferreira AV; Dalle HM; Da Silva TA
    Appl Radiat Isot; 2019 Nov; 153():108823. PubMed ID: 31400649
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Characterisation of neutron field in the polyethylene neutron irradiator.
    Rataj J; Suk P; Bílý T; Štefánik M; Frýbort J
    Appl Radiat Isot; 2021 Feb; 168():109529. PubMed ID: 33307442
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Enhancement of a 252Cf-based neutron beam via subcritical multiplication for neutron capture therapy.
    Wang CK; Zino JF; Kessler G
    Appl Radiat Isot; 2000; 53(4-5):811-4. PubMed ID: 11003524
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Calculation and Validation of the Response Matrix for a Neutron Multisphere Spectrometer with an Indium Central Detector.
    Vlk P; Pavlovic M
    Radiat Prot Dosimetry; 2018 Apr; 179(1):1-8. PubMed ID: 29036730
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Thermal and epithermal neutron flux distributions measurement in thermal column of TRR using an experimental-simulation method.
    Adeli R; Kasesaz Y; Shirmardi SP; Ezaty A
    Appl Radiat Isot; 2018 Mar; 133():100-104. PubMed ID: 29335157
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Neutron and photon shielding benchmark calculations by MCNP on the LR-0 experimental facility.
    Hordósy G
    Radiat Prot Dosimetry; 2005; 116(1-4 Pt 2):32-4. PubMed ID: 16604591
    [TBL] [Abstract][Full Text] [Related]  

  • 35. A study on the optimum fast neutron flux for boron neutron capture therapy of deep-seated tumors.
    Rasouli FS; Masoudi SF
    Appl Radiat Isot; 2015 Feb; 96():45-51. PubMed ID: 25479433
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Total Ambient Dose Equivalent Buildup Factor Determination for Nbs04 Concrete.
    Duckic P; Hayes RB
    Health Phys; 2018 Jun; 114(6):569-581. PubMed ID: 29543602
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Study of the neutron beam line shield design for JSNS.
    Kawai M; Saito K; Sanami T; Nakao N; Maekawa F
    Radiat Prot Dosimetry; 2005; 115(1-4):580-6. PubMed ID: 16381789
    [TBL] [Abstract][Full Text] [Related]  

  • 38. TORT/MCNP coupling method for the calculation of neutron flux around a core of BWR.
    Kurosawa M
    Radiat Prot Dosimetry; 2005; 116(1-4 Pt 2):513-7. PubMed ID: 16604689
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Experimental verification of beam characteristics for cyclotron-based epithermal neutron source (C-BENS).
    Tanaka H; Sakurai Y; Suzuki M; Masunaga S; Mitsumoto T; Fujita K; Kashino G; Kinashi Y; Liu Y; Takada M; Ono K; Maruhashi A
    Appl Radiat Isot; 2011 Dec; 69(12):1642-5. PubMed ID: 21463945
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Monte Carlo methods of neutron beam design for neutron capture therapy at the MIT Research Reactor (MITR-II).
    Clement SD; Choi JR; Zamenhof RG; Yanch JC; Harling OK
    Basic Life Sci; 1990; 54():51-69. PubMed ID: 2268248
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 8.