BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

175 related articles for article (PubMed ID: 12102570)

  • 1. Effect of covalently bound heparin coating on patency and biocompatibility of long-term indwelling catheters in the rat jugular vein.
    Foley PL; Barthel CH; Brausa HR
    Comp Med; 2002 Jun; 52(3):243-8. PubMed ID: 12102570
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Chronic performance of polyurethane catheters covalently coated with ATH complex: a rabbit jugular vein model.
    Klement P; Du YJ; Berry LR; Tressel P; Chan AK
    Biomaterials; 2006 Oct; 27(29):5107-17. PubMed ID: 16781768
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Gross and histopathological observations of long-term catheterized vessels in experimental sheep.
    Barraza ML; Strickland JR; Zepeda H; Taylor JB; Krehbiel CR; Bell GS; Klotz JL
    J Vet Med A Physiol Pathol Clin Med; 2006 Jun; 53(5):230-8. PubMed ID: 16737512
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Long-term jugular vein catheterization in horses.
    Spurlock SL; Spurlock GH; Parker G; Ward MV
    J Am Vet Med Assoc; 1990 Feb; 196(3):425-30. PubMed ID: 2298671
    [TBL] [Abstract][Full Text] [Related]  

  • 5. The use of rifampicin-miconazole-impregnated catheters reduces the incidence of femoral and jugular catheter-related bacteremia.
    Lorente L; Lecuona M; Ramos MJ; Jiménez A; Mora ML; Sierra A
    Clin Infect Dis; 2008 Nov; 47(9):1171-5. PubMed ID: 18808356
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Validation of the use of long-term indwelling jugular catheters in a rat model of cardiotoxicity.
    Wachtman LM; Browning MD; Bedja D; Pin S; Gabrielson KL
    J Am Assoc Lab Anim Sci; 2006 Sep; 45(5):55-64. PubMed ID: 16995648
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Chronic central vein catheterization for intraoperative and long-term venous access in swine.
    Moritz MW; Dawe EJ; Holliday JF; Elliott S; Mattei JA; Thomas AL
    Lab Anim Sci; 1989 Mar; 39(2):153-5. PubMed ID: 2709806
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Heparin-coated angiographic catheters: an in vivo comparison of three coating methods with different heparin release profiles.
    Lee KH; Han JK; Byun Y; Moon HT; Yoon CJ; Kim SJ; Choi BI
    Cardiovasc Intervent Radiol; 2004; 27(5):507-11. PubMed ID: 15383856
    [TBL] [Abstract][Full Text] [Related]  

  • 9. The efficacy of heparinization in prolonging patency of arterial and central venous catheters in children: a randomized double-blind trial.
    de Neef M; Heijboer H; van Woensel JB; de Haan RJ
    Pediatr Hematol Oncol; 2002 Dec; 19(8):553-60. PubMed ID: 12487830
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Improving the Patency of Jugular Vein Catheters in Sprague-Dawley Rats by Using an Antiseptic Nitrocellulose Coating.
    De Luca T; Szilágyi KL; Hargreaves KA; Collins KS; Benson EA
    J Am Assoc Lab Anim Sci; 2018 Sep; 57(5):520-528. PubMed ID: 30075826
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Keeping central venous lines open: a prospective comparison of heparin, vitamin C and sodium chloride sealing solutions in medical patients.
    Rabe C; Gramann T; Sons X; Berna M; González-Carmona MA; Klehr HU; Sauerbruch T; Caselmann WH
    Intensive Care Med; 2002 Aug; 28(8):1172-6. PubMed ID: 12185445
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Tunneled internal jugular catheters in adult patients: comparison of outcomes in hemodialysis versus infusion catheters.
    Peynircioglu B; Ozkan F; Canyigit M; Cil BE; Balkanci F
    Acta Radiol; 2007 Jul; 48(6):613-9. PubMed ID: 17611867
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Restoring patency of long-term central venous access devices.
    Holcombe BJ; Forloines-Lynn S; Garmhausen LW
    J Intraven Nurs; 1992; 15(1):36-41. PubMed ID: 1564598
    [TBL] [Abstract][Full Text] [Related]  

  • 14. JUGULAR CENTRAL VENOUS CATHETER PLACEMENT THROUGH A MODIFIED SELDINGER TECHNIQUE FOR LONG-TERM VENOUS ACCESS IN CHELONIANS.
    Pardo MA; Divers S
    J Zoo Wildl Med; 2016 Mar; 47(1):286-90. PubMed ID: 27010289
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Vascular access recirculation in hemodialysis patients with two noncuffed, single-lumen, jugular catheters in the same jugular vein.
    Kovac J; Buturović-Ponikvar J; Ponikvar R
    Ther Apher Dial; 2009 Aug; 13(4):350-3. PubMed ID: 19695073
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Atrial cannulation for long-term sequential blood collection in gilts.
    Kemp C; Kruger JS
    Am J Vet Res; 1987 Jun; 48(6):990-1. PubMed ID: 3605816
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Long-term blood access by catheters implanted into arteriovenous fistulas of sheep.
    Dennis MB; Cole JJ; Jensen WM; Scribner BH
    Lab Anim Sci; 1984 Aug; 34(4):388-92. PubMed ID: 6482380
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Evaluation of a polyurethane jugular catheter in cats placed using a modified Seldinger technique.
    Martin GJ; Rand JS
    Aust Vet J; 1999 Apr; 77(4):250-4. PubMed ID: 10330557
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Urokinase: new indication. Thrombosed venous and dialysis catheters: when heparin fails. Urokinase clears about 75% of thrombosed venous catheters intended for long-term use with a dose-related increase in the bleeding risk.
    Prescrire Int; 2009 Jun; 18(101):118. PubMed ID: 19637430
    [No Abstract]   [Full Text] [Related]  

  • 20. Use of heparin-coated central venous lines to prevent catheter-related bloodstream infection.
    Abdelkefi A; Achour W; Ben Othman T; Ladeb S; Torjman L; Lakhal A; Ben Hassen A; Hsairi M; Ben Abdeladhim A
    J Support Oncol; 2007 Jun; 5(6):273-8. PubMed ID: 17624052
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.