These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

143 related articles for article (PubMed ID: 12108659)

  • 1. Determination of hexavalent chromium at the level of the California Public Health Goal by ion chromatography.
    Thomas DH; Rohrer JS; Jackson PE; Pak T; Scott JN
    J Chromatogr A; 2002 May; 956(1-2):255-9. PubMed ID: 12108659
    [TBL] [Abstract][Full Text] [Related]  

  • 2. [Investigation of concentration levels of chromium(VI) in bottled mineral and spring waters by high performance ion chromatography technique with application of postcolumn reaction with 1,5-diphenylcarbazide and VIS detection].
    Swiecicka D; Garboś S
    Rocz Panstw Zakl Hig; 2008; 59(4):397-405. PubMed ID: 19227250
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Human health risk and exposure assessment of chromium (VI) in tap water.
    Paustenbach DJ; Finley BL; Mowat FS; Kerger BD
    J Toxicol Environ Health A; 2003 Jul; 66(14):1295-339. PubMed ID: 12851114
    [TBL] [Abstract][Full Text] [Related]  

  • 4. On-line preconcentration and determination of chromium(VI) in waters by high-performance liquid chromatography using precolumn complexation with 1,5-diphenylcarbazide.
    Padarauskas A; Judzentiene A; Naujalis E; Paliulionyte V
    J Chromatogr A; 1998 May; 808(1-2):193-9. PubMed ID: 9652118
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Simultaneous determination of Cr(III) and Cr(VI) in tannery wastewater using low pressure ion chromatography combined with flow injection spectrophotometry.
    Chen S; Zhang X; Yu L; Wang L; Li H
    Spectrochim Acta A Mol Biomol Spectrosc; 2012 Mar; 88():49-55. PubMed ID: 22209249
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Determination of hexavalent chromium by on-line dialysis ion chromatography in a matrix of strong colourants and trivalent chromium.
    Ganeshjeevan R; Chandrasekar R; Yuvaraj S; Radhakrishnan G
    J Chromatogr A; 2003 Feb; 988(1):151-9. PubMed ID: 12647830
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Comparison of three sampling and analytical methods for the determination of airborne hexavalent chromium.
    Boiano JM; Wallace ME; Sieber WK; Groff JH; Wang J; Ashley K
    J Environ Monit; 2000 Aug; 2(4):329-33. PubMed ID: 11249787
    [TBL] [Abstract][Full Text] [Related]  

  • 8. A remote in situ monitor based on continuous flow analysis for the quantitation of sub-micromolar levels of hexavalent chromium in natural waters.
    Singer Pressman MA; Aldstadt Iii JH
    J Environ Monit; 2005 Aug; 7(8):809-13. PubMed ID: 16049583
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Evaluation of sequential extraction procedures for soluble and insoluble hexavalent chromium compounds in workplace air samples.
    Ashley K; Applegate GT; Marcy AD; Drake PL; Pierce PA; Carabin N; Demange M
    J Environ Monit; 2009 Feb; 11(2):318-25. PubMed ID: 19212588
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Improved method for the determination of trace perchlorate in ground and drinking waters by ion chromatography.
    Jackson PE; Gokhale S; Streib T; Rohrer JS; Pohl CA
    J Chromatogr A; 2000 Aug; 888(1-2):151-8. PubMed ID: 10949483
    [TBL] [Abstract][Full Text] [Related]  

  • 11. [Simultaneous determination of trivalent chromium and hexavalent chromium in plastics by accelerated solvent extraction-ion chromatography].
    Yu R; Hu Z; Ye M; Che J
    Se Pu; 2012 Apr; 30(4):409-13. PubMed ID: 22799201
    [TBL] [Abstract][Full Text] [Related]  

  • 12. A Robust Flow-Based System for the Spectrophotometric Determination of Cr(VI) in Recreational Waters.
    Ribas TCF; Mesquita RBR; Machado A; Miranda JLA; Marshall G; Bordalo A; Rangel AOSS
    Molecules; 2022 Mar; 27(7):. PubMed ID: 35408472
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Rapid determination of chromium(VI) in electroplating waste water by use of a spectrophotometric flow injection system.
    Yuan D; Fu D; Wang R; Yuan J
    Spectrochim Acta A Mol Biomol Spectrosc; 2008 Nov; 71(1):276-9. PubMed ID: 18262833
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Analysis of hexavalent chromium in Colla corii asini with on-line sample pretreatment valve-switching ion chromatography.
    Yang Y; He J; Huang Z; Zhong N; Zhu Z; Jiang R; You J; Lu X; Zhu Y; He S
    J Chromatogr A; 2013 Aug; 1305():171-5. PubMed ID: 23891376
    [TBL] [Abstract][Full Text] [Related]  

  • 15. A novel fiber-packed column for on-line preconcentration and speciation analysis of chromium in drinking water with flame atomic absorption spectrometry.
    Monasterio RP; Altamirano JC; Martínez LD; Wuilloud RG
    Talanta; 2009 Feb; 77(4):1290-4. PubMed ID: 19084637
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Determination of trace concentrations of hexavalent chromium.
    Gardner M; Comber S
    Analyst; 2002 Jan; 127(1):153-6. PubMed ID: 11827384
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Direct spectrophotometric analysis of Cr(VI) using a liquid waveguide capillary cell.
    Levitskaia TG; O'Hara MJ; Sinkov SI; Egorov OB
    Appl Spectrosc; 2008 Jan; 62(1):107-15. PubMed ID: 18230215
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Anion-exchange high-performance liquid chromatographic determination of ascorbic acid and hexavalent chromium in rat lung preparations after treatment with sodium chromate in vitro and in vivo.
    Suzuki Y; Fukuda K
    J Chromatogr; 1989 Apr; 489(2):283-90. PubMed ID: 2753952
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Determination of hexavalent chromium concentration in industrial waste incinerator stack gas by using a modified ion chromatography with post-column derivatization method.
    Miyake Y; Tokumura M; Iwazaki Y; Wang Q; Amagai T; Horii Y; Otsuka H; Tanikawa N; Kobayashi T; Oguchi M
    J Chromatogr A; 2017 Jun; 1502():24-29. PubMed ID: 28473202
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Quantitative analysis of manganese, chromium and molybdenum by ion-pair reversed-phase high-performance liquid chromatography with pre-column derivatization and UV-visible detection.
    Sun HL; Liu HM; Tsai SJ
    J Chromatogr A; 1999 Oct; 857(1-2):351-7. PubMed ID: 10536856
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.