These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

204 related articles for article (PubMed ID: 12108781)

  • 1. Investigation of photon beam output factors for conformal radiation therapy--Monte Carlo simulations and measurements.
    Haryanto F; Fippel M; Laub W; Dohm O; Nüsslin F
    Phys Med Biol; 2002 Jun; 47(11):N133-43. PubMed ID: 12108781
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Using Monte Carlo simulations to commission photon beam output factors--a feasibility study.
    Ding GX
    Phys Med Biol; 2003 Dec; 48(23):3865-74. PubMed ID: 14703163
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Development and optimization of a beam shaper device for a mobile dedicated IOERT accelerator.
    Soriani A; Iaccarino G; Felici G; Ciccotelli A; Pinnaro P; Giordano C; Benassi M; D'Andrea M; Bellesi L; Strigari L
    Med Phys; 2012 Oct; 39(10):6080-9. PubMed ID: 23039647
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Determination of the KQclinfclin,Qmsr fmsr correction factors for detectors used with an 800 MU/min CyberKnife(®) system equipped with fixed collimators and a study of detector response to small photon beams using a Monte Carlo method.
    Moignier C; Huet C; Makovicka L
    Med Phys; 2014 Jul; 41(7):071702. PubMed ID: 24989371
    [TBL] [Abstract][Full Text] [Related]  

  • 5. 6-MV small field output factors: intra-/intermachine comparison and implementation of TRS-483 using various detectors and several linear accelerators.
    Ghazal M; Westermark M; Kaveckyte V; Carlsson-Tedgren Å; Benmakhlouf H
    Med Phys; 2019 Nov; 46(11):5350-5359. PubMed ID: 31532831
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Using a Monte Carlo model to predict dosimetric properties of small radiotherapy photon fields.
    Scott AJ; Nahum AE; Fenwick JD
    Med Phys; 2008 Oct; 35(10):4671-84. PubMed ID: 18975713
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Experimental determination of field factors ([Formula: see text]) for small radiotherapy beams using the daisy chain correction method.
    Lárraga-Gutiérrez JM
    Phys Med Biol; 2015 Aug; 60(15):5813-31. PubMed ID: 26161448
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Monte Carlo simulation and dosimetric verification of radiotherapy beam modifiers.
    Spezi E; Lewis DG; Smith CW
    Phys Med Biol; 2001 Nov; 46(11):3007-29. PubMed ID: 11720360
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Output correction factors for nine small field detectors in 6 MV radiation therapy photon beams: a PENELOPE Monte Carlo study.
    Benmakhlouf H; Sempau J; Andreo P
    Med Phys; 2014 Apr; 41(4):041711. PubMed ID: 24694131
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Monte Carlo calculated correction factors for diodes and ion chambers in small photon fields.
    Czarnecki D; Zink K
    Phys Med Biol; 2013 Apr; 58(8):2431-44. PubMed ID: 23514734
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Total skin electron therapy treatment verification: Monte Carlo simulation and beam characteristics of large non-standard electron fields.
    Pavón EC; Sánchez-Doblado F; Leal A; Capote R; Lagares JI; Perucha M; Arráns R
    Phys Med Biol; 2003 Sep; 48(17):2783-96. PubMed ID: 14516101
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Commissioning stereotactic radiosurgery beams using both experimental and theoretical methods.
    Ding GX; Duggan DM; Coffey CW
    Phys Med Biol; 2006 May; 51(10):2549-66. PubMed ID: 16675869
    [TBL] [Abstract][Full Text] [Related]  

  • 13. A virtual photon source model of an Elekta linear accelerator with integrated mini MLC for Monte Carlo based IMRT dose calculation.
    Sikora M; Dohm O; Alber M
    Phys Med Biol; 2007 Aug; 52(15):4449-63. PubMed ID: 17634643
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Deriving detector-specific correction factors for rectangular small fields using a scintillator detector.
    Qin Y; Zhong H; Wen N; Snyder K; Huang Y; Chetty IJ
    J Appl Clin Med Phys; 2016 Nov; 17(6):379-391. PubMed ID: 27929510
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Monte Carlo study of in-field and out-of-field dose distributions from a linear accelerator operating with and without a flattening-filter.
    Almberg SS; Frengen J; Lindmo T
    Med Phys; 2012 Aug; 39(8):5194-203. PubMed ID: 22894444
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Development of a Monte Carlo model for the Brainlab microMLC.
    Belec J; Patrocinio H; Verhaegen F
    Phys Med Biol; 2005 Mar; 50(5):787-99. PubMed ID: 15798255
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Monte Carlo modeling of small photon fields: quantifying the impact of focal spot size on source occlusion and output factors, and exploring miniphantom design for small-field measurements.
    Scott AJ; Nahum AE; Fenwick JD
    Med Phys; 2009 Jul; 36(7):3132-44. PubMed ID: 19673212
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Properties of IBA Razor Nano Chamber in small-field radiation therapy using 6 MV FF, 6 MV FFF, and 10 MV FFF photon beams.
    Partanen M; Niemelä J; Ojala J; Keyriläinen J; Kapanen M
    Acta Oncol; 2021 Nov; 60(11):1419-1424. PubMed ID: 34596486
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Properties of a commercial PTW-60019 synthetic diamond detector for the dosimetry of small radiotherapy beams.
    Lárraga-Gutiérrez JM; Ballesteros-Zebadúa P; Rodríguez-Ponce M; García-Garduño OA; de la Cruz OO
    Phys Med Biol; 2015 Jan; 60(2):905-24. PubMed ID: 25564826
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Diamond detector versus silicon diode and ion chamber in photon beams of different energy and field size.
    Bucciolini M; Buonamici FB; Mazzocchi S; De Angelis C; Onori S; Cirrone GA
    Med Phys; 2003 Aug; 30(8):2149-54. PubMed ID: 12945980
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 11.