These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

105 related articles for article (PubMed ID: 12111970)

  • 1. Direct reconstruction of MR images from data acquired on a non-Cartesian grid using an equal-phase-line algorithm.
    Qian Y; Lin J; Jin D
    Magn Reson Med; 2002 Jun; 47(6):1228-33. PubMed ID: 12111970
    [TBL] [Abstract][Full Text] [Related]  

  • 2. A least squares quantization table method for direct reconstruction of MR images with non-Cartesian trajectory.
    Liang D; Lam EY; Fung GS
    J Magn Reson; 2007 Sep; 188(1):141-50. PubMed ID: 17646119
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Fast direct fourier reconstruction of radial and PROPELLER MRI data using the chirp transform algorithm on graphics hardware.
    Feng Y; Song Y; Wang C; Xin X; Feng Q; Chen W
    Magn Reson Med; 2013 Oct; 70(4):1087-94. PubMed ID: 23165973
    [TBL] [Abstract][Full Text] [Related]  

  • 4. A CUDA-based reverse gridding algorithm for MR reconstruction.
    Yang J; Feng C; Zhao D
    Magn Reson Imaging; 2013 Feb; 31(2):313-23. PubMed ID: 22898698
    [TBL] [Abstract][Full Text] [Related]  

  • 5. A rapid look-up table method for reconstructing MR images from arbitrary K-space trajectories.
    Dale B; Wendt M; Duerk JL
    IEEE Trans Med Imaging; 2001 Mar; 20(3):207-17. PubMed ID: 11341710
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Reconstruction of undersampled non-Cartesian data sets using pseudo-Cartesian GRAPPA in conjunction with GROG.
    Seiberlich N; Breuer F; Heidemann R; Blaimer M; Griswold M; Jakob P
    Magn Reson Med; 2008 May; 59(5):1127-37. PubMed ID: 18429026
    [TBL] [Abstract][Full Text] [Related]  

  • 7. [Software for MR image reconstruction from data acquired on an irregular k-space trajectory].
    Qian Y; Liu L; Xu K; Lin J
    Sheng Wu Yi Xue Gong Cheng Xue Za Zhi; 2003 Jun; 20(2):322-4, 327. PubMed ID: 12856610
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Reconstruction of MR images from data acquired on an arbitrary k-space trajectory using the same-image weight.
    Qian Y; Lin J; Jin D
    Magn Reson Med; 2002 Aug; 48(2):306-11. PubMed ID: 12210939
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Non-Iterative Regularized reconstruction Algorithm for Non-CartesiAn MRI: NIRVANA.
    Kashyap S; Yang Z; Jacob M
    Magn Reson Imaging; 2011 Feb; 29(2):222-9. PubMed ID: 21144688
    [TBL] [Abstract][Full Text] [Related]  

  • 10. On the optimality of the gridding reconstruction algorithm.
    Sedarat H; Nishimura DG
    IEEE Trans Med Imaging; 2000 Apr; 19(4):306-17. PubMed ID: 10909926
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Highly undersampled magnetic resonance image reconstruction using two-level Bregman method with dictionary updating.
    Liu Q; Wang S; Yang K; Luo J; Zhu Y; Liang D
    IEEE Trans Med Imaging; 2013 Jul; 32(7):1290-301. PubMed ID: 23559032
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Real-time image reconstruction for spiral MRI using fixed-point calculation.
    Liao JR
    IEEE Trans Med Imaging; 2000 Jul; 19(7):690-8. PubMed ID: 11055784
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Iterative reconstruction of single-shot spiral MRI with off resonance.
    Harshbarger TB; Twieg DB
    IEEE Trans Med Imaging; 1999 Mar; 18(3):196-205. PubMed ID: 10363698
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Phase-constrained parallel MR image reconstruction.
    Willig-Onwuachi JD; Yeh EN; Grant AK; Ohliger MA; McKenzie CA; Sodickson DK
    J Magn Reson; 2005 Oct; 176(2):187-98. PubMed ID: 16027017
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Chemical-shift imaging utilizing the positional shifts along the readout gradient direction.
    Altbach MI; Trouard TP; Van de Walle R; Theilmann RJ; Clarkson E; Barrett HH; Gmitro AF
    IEEE Trans Med Imaging; 2001 Nov; 20(11):1156-66. PubMed ID: 11700741
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Non-Cartesian data reconstruction using GRAPPA operator gridding (GROG).
    Seiberlich N; Breuer FA; Blaimer M; Barkauskas K; Jakob PM; Griswold MA
    Magn Reson Med; 2007 Dec; 58(6):1257-65. PubMed ID: 17969027
    [TBL] [Abstract][Full Text] [Related]  

  • 17. An improved algorithm for rotational motion artifact suppression in MRI.
    Weerasinghe C; Yan H
    IEEE Trans Med Imaging; 1998 Apr; 17(2):310-7. PubMed ID: 9688164
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Alias-free image reconstruction using Fresnel transform in the phase-scrambling Fourier imaging technique.
    Ito S; Yamada Y
    Magn Reson Med; 2008 Aug; 60(2):422-30. PubMed ID: 18666133
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Radial imaging with multipolar magnetic encoding fields.
    Schultz G; Weber H; Gallichan D; Witschey WR; Welz AM; Cocosco CA; Hennig J; Zaitsev M
    IEEE Trans Med Imaging; 2011 Dec; 30(12):2134-45. PubMed ID: 21843982
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Reconstruction of MR images from data acquired on a general nonregular grid by pseudoinverse calculation.
    Van de Walle R; Barrett HH; Myers KJ; Altbach MI; Desplanques B; Gmitro AF; Cornelis J; Lemahieu I
    IEEE Trans Med Imaging; 2000 Dec; 19(12):1160-7. PubMed ID: 11212364
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.