BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

230 related articles for article (PubMed ID: 12116123)

  • 1. High-resolution computer simulation of the dynamics of isoelectric focusing using carrier ampholytes: the post-separation stabilizing phase revisited.
    Mosher RA; Thormann W
    Electrophoresis; 2002 Jun; 23(12):1803-14. PubMed ID: 12116123
    [TBL] [Abstract][Full Text] [Related]  

  • 2. High-resolution computer simulation of the dynamics of isoelectric focusing of proteins.
    Thormann W; Huang T; Pawliszyn J; Mosher RA
    Electrophoresis; 2004 Jan; 25(2):324-37. PubMed ID: 14743485
    [TBL] [Abstract][Full Text] [Related]  

  • 3. High-resolution computer simulation of the dynamics of isoelectric focusing using carrier ampholytes: focusing with concurrent electrophoretic mobilization is an isotachophoretic process.
    Thormann W; Mosher RA
    Electrophoresis; 2006 Mar; 27(5-6):968-83. PubMed ID: 16523465
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Dynamics of capillary isoelectric focusing in the absence of fluid flow: high-resolution computer simulation and experimental validation with whole column optical imaging.
    Mao Q; Pawliszyn J; Thormann W
    Anal Chem; 2000 Nov; 72(21):5493-502. PubMed ID: 11080905
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Electrically controlled focusing of proteins and ampholytes between two modified electrolytes. Computer simulation.
    Deml M; Pospíchal J
    Appl Theor Electrophor; 1994; 4(3):107-15. PubMed ID: 7612692
    [TBL] [Abstract][Full Text] [Related]  

  • 6. High-resolution computer simulation of the dynamics of isoelectric focusing: in quest of more realistic input parameters for carrier ampholytes.
    Mosher RA; Thormann W
    Electrophoresis; 2008 Mar; 29(5):1036-47. PubMed ID: 18219653
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Effects of ampholyte concentration on protein behavior in on-chip isoelectric focusing.
    Shim J; Dutta P; Ivory CF
    Electrophoresis; 2008 Mar; 29(5):1026-35. PubMed ID: 18257108
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Native protein blotting after isoelectric focusing in fabric reinforced polyacrylamide gels in carrier ampholyte generated or immobilized pH gradients.
    Kinzkofer-Peresch A; Patestos NP; Fauth M; Kögel F; Zok R; Radola BJ
    Electrophoresis; 1988 Sep; 9(9):497-511. PubMed ID: 3243247
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Modeling of formation and prevention of a pure water zone in capillary isoelectric focusing with narrow pH range carrier ampholytes.
    Takácsi-Nagy A; Kilár F; Thormann W
    Electrophoresis; 2017 Mar; 38(5):677-688. PubMed ID: 27699824
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Conductivity properties of carrier ampholyte pH gradients in isoelectric focusing.
    Stoyanov AV; Das C; Fredrickson CK; Fan ZH
    Electrophoresis; 2005 Jan; 26(2):473-9. PubMed ID: 15657903
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Characterization of genetic variants of human serum transferrin by isoelectric focusing: comparison between conventional and immobilized pH gradients, and application to a protocol for paternity testing.
    Pascali VL; Dobosz M; Destro-Bisol G; D'Aloja E
    Electrophoresis; 1988 Aug; 9(8):411-7. PubMed ID: 3234383
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Isoelectric focusing in immobilized pH gradients with carrier ampholytes added for high-resolution phenotyping of bovine beta-lactoglobulins: characterization of a new genetic variant.
    Krause I; Buchberger J; Weiss G; Pflügler M; Klostermeyer H
    Electrophoresis; 1988 Sep; 9(9):609-13. PubMed ID: 3243259
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Modeling of electroosmotic and electrophoretic mobilization in capillary and microchip isoelectric focusing.
    Thormann W; Caslavska J; Mosher RA
    J Chromatogr A; 2007 Jul; 1155(2):154-63. PubMed ID: 17307189
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Experimental and theoretical dynamics of isoelectric focusing: IV. Cathodic, anodic and symmetrical drifts of the pH gradient.
    Mosher RA; Thormann W
    Electrophoresis; 1990 Sep; 11(9):717-23. PubMed ID: 2257843
    [TBL] [Abstract][Full Text] [Related]  

  • 15. High-resolution dynamic computer simulation analysis of the behavior of sample components with pI values outside the pH gradient established by carrier ampholyte CIEF.
    Thormann W; Kilár F
    Electrophoresis; 2013 Mar; 34(5):716-24. PubMed ID: 23229109
    [TBL] [Abstract][Full Text] [Related]  

  • 16. High-resolution computer simulation of electrophoretic mobilization in isoelectric focusing.
    Thormann W; Mosher RA
    Electrophoresis; 2008 Apr; 29(8):1676-86. PubMed ID: 18383018
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Carrier ampholytes rehabilitated: gel isoelectric focusing on pH gradients visualized in real-time by automated fluorescence scanning in the HPGE-1000 apparatus.
    Gombocz E; Cortez E
    Electrophoresis; 1999 Jun; 20(7):1365-72. PubMed ID: 10424457
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Capillary isoelectric focusing and isoelectric buffers: an evolving scenario.
    Righetti PG; Bossi A; Gelfi C
    J Capillary Electrophor; 1997; 4(2):47-59. PubMed ID: 9624569
    [TBL] [Abstract][Full Text] [Related]  

  • 19. On-chip isoelectric focusing using photopolymerized immobilized pH gradients.
    Sommer GJ; Singh AK; Hatch AV
    Anal Chem; 2008 May; 80(9):3327-33. PubMed ID: 18341355
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Development of crosslinked polyamines suitable for synthesizing complex ampholytes for isoelectric focusing.
    McWhinney DR; DeShong P; Rodkey LS
    Appl Theor Electrophor; 1995; 4(4):167-73. PubMed ID: 7599253
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 12.