These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

71 related articles for article (PubMed ID: 12118808)

  • 1. Open stent-grafting for aortic arch aneurysm is associated with increased risk of paraplegia.
    Miyairi T; Kotsuka Y; Ezure M; Ono M; Morota T; Kubota H; Shibata K; Ueno K; Takamoto S
    Ann Thorac Surg; 2002 Jul; 74(1):83-9. PubMed ID: 12118808
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Hybrid approaches in the treatment of aortic arch aneurysms: postoperative and midterm outcomes.
    Bavaria J; Vallabhajosyula P; Moeller P; Szeto W; Desai N; Pochettino A
    J Thorac Cardiovasc Surg; 2013 Mar; 145(3 Suppl):S85-90. PubMed ID: 23260461
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Development of Collaterals to the Spinal Cord after Endovascular Stent Graft Repair of Thoracic Aneurysms.
    Fukui S; Tanaka H; Kobayashi K; Kajiyama T; Mitsuno M; Yamamura M; Ryomoto M; Miyamoto Y
    Eur J Vasc Endovasc Surg; 2016 Dec; 52(6):801-807. PubMed ID: 27776939
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Open surgical repair of descending thoracic aortic aneurysms in the endovascular era: a 9-year single-center study.
    Kieffer E; Chiche L; Cluzel P; Godet G; Koskas F; Bahnini A
    Ann Vasc Surg; 2009; 23(1):60-6. PubMed ID: 18809288
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Neurologic complications associated with endovascular repair of thoracic aortic pathology: Incidence and risk factors. a study from the European Collaborators on Stent/Graft Techniques for Aortic Aneurysm Repair (EUROSTAR) registry.
    Buth J; Harris PL; Hobo R; van Eps R; Cuypers P; Duijm L; Tielbeek X
    J Vasc Surg; 2007 Dec; 46(6):1103-1110; discussion 1110-1. PubMed ID: 18154984
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Spinal cord ischemia after elective endovascular stent-graft repair of the thoracic aorta.
    Kawaharada N; Morishita K; Kurimoto Y; Hyodoh H; Ito T; Harada R; Kuwaki K; Higami T
    Eur J Cardiothorac Surg; 2007 Jun; 31(6):998-1003; discussion 1003. PubMed ID: 17353130
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Early and midterm outcomes of open stent-graft treatment for distal aortic arch aneurysm.
    Yamada K; Mochizuki T; Tsubota H; Funamoto M
    Gen Thorac Cardiovasc Surg; 2008 Oct; 56(10):490-7. PubMed ID: 18854925
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Evaluation of visible spinal arteries on computed tomography angiography before and after branched stent graft repair for thoracoabdominal aortic aneurysm.
    Gallis K; Kasprzak PM; Cucuruz B; Kopp R
    J Vasc Surg; 2017 Jun; 65(6):1577-1583. PubMed ID: 28216346
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Paraplegia after open surgery using endovascular stent graft for aortic arch aneurysm.
    Miyairi T; Kotsuka Y; Morota T; Kubota H; Shibata K; Ikeda Y; Kitamura T; Kashima T; Takamoto S
    J Thorac Cardiovasc Surg; 2001 Dec; 122(6):1240-3. PubMed ID: 11726905
    [No Abstract]   [Full Text] [Related]  

  • 10. Pivotal results of the Medtronic Vascular Talent Thoracic Stent Graft System: the VALOR trial.
    Fairman RM; Criado F; Farber M; Kwolek C; Mehta M; White R; Lee A; Tuchek JM;
    J Vasc Surg; 2008 Sep; 48(3):546-54. PubMed ID: 18572352
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Fenestrated and branched stent-grafting after previous open or endovascular aortic surgery.
    Katsargyris A; Oikonomou K; Spinelli D; Houthoofd S; Verhoeven EL
    J Cardiovasc Surg (Torino); 2014 Apr; 55(2 Suppl 1):95-103. PubMed ID: 24796902
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Analysis of Risk Factors for Early Type I Endoleaks After Thoracic Endovascular Aneurysm Repair.
    Kanaoka Y; Ohki T; Maeda K; Baba T
    J Endovasc Ther; 2017 Feb; 24(1):89-96. PubMed ID: 27760812
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Risk factor analysis for ascending aorta and aortic arch repair using selective cerebral perfusion with open technique: role of open-stent graft placement.
    Nakamura K; Onitsuka T; Yano M; Yano Y; Matsuyama M; Furukawa K
    J Cardiovasc Surg (Torino); 2006 Dec; 47(6):659-65. PubMed ID: 17043612
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Strategies to manage paraplegia risk after endovascular stent repair of descending thoracic aortic aneurysms.
    Cheung AT; Pochettino A; McGarvey ML; Appoo JJ; Fairman RM; Carpenter JP; Moser WG; Woo EY; Bavaria JE
    Ann Thorac Surg; 2005 Oct; 80(4):1280-8; discussion 1288-9. PubMed ID: 16181855
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Endovascular Repair of Thoracoabdominal and Arch Aneurysms in Patients with Connective Tissue Disease Using Branched and Fenestrated Devices.
    Clough RE; Martin-Gonzalez T; Van Calster K; Hertault A; Spear R; Azzaoui R; Sobocinski J; Haulon S
    Ann Vasc Surg; 2017 Oct; 44():158-163. PubMed ID: 28546044
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Early and midterm outcome of a novel technique to simplify the hybrid procedures in the treatment of thoracoabdominal and pararenal aortic aneurysms.
    Donas KP; Lachat M; Rancic Z; Oberkofler C; Pfammatter T; Guber I; Veith FJ; Mayer D
    J Vasc Surg; 2009 Dec; 50(6):1280-4. PubMed ID: 19958984
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Hybrid repair of complex thoracic aortic arch pathology: long-term outcomes of extra-anatomic bypass grafting of the supra-aortic trunk.
    Lotfi S; Clough RE; Ali T; Salter R; Young CP; Bell R; Modarai B; Taylor P
    Cardiovasc Intervent Radiol; 2013 Feb; 36(1):46-55. PubMed ID: 22526104
    [TBL] [Abstract][Full Text] [Related]  

  • 18. New-generation stent grafts for endovascular management of thoracic pseudoaneurysms after aortic coarctation repair.
    Perera AH; Rudarakanchana N; Hamady M; Kashef E; Mireskandari M; Uebing A; Cheshire NJ; Bicknell CD
    J Vasc Surg; 2014 Aug; 60(2):330-6. PubMed ID: 24767711
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Midterm results for endovascular stent grafts via median sternotomy for distal aortic arch aneurysm.
    Sakurai K; Usui A; Ueda Y; Akita T; Yoshikawa M; Murayama H; Ishiguchi T; Tajima K
    J Artif Organs; 2006; 9(3):149-53. PubMed ID: 16998699
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Two autopsy cases of rupture of the aorta by fistula formation after thoracic endovascular aortic repair and open stent-grafting on aortic arch aneurysm.
    Mori S; Kimura S; Ro A; Hayakawa A; Funakoshi I; Fukunaga T; Mizukami H
    Cardiovasc Pathol; 2019; 39():61-66. PubMed ID: 30665185
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 4.