162 related articles for article (PubMed ID: 12132713)
1. Measurement of TVLs in lead for 4, 6 and 10 MV bremsstrahlung x-ray beams at scattering angles between 30 degrees and 135 degrees.
Nogueira IP; Biggs PJ
Health Phys; 2002 Aug; 83(2):255-60. PubMed ID: 12132713
[TBL] [Abstract][Full Text] [Related]
2. Do angles of obliquity apply to 30 degrees scattered radiation from megavoltage beams?
Biggs PJ; Styczynski JR
Health Phys; 2008 Oct; 95(4):425-32. PubMed ID: 18784515
[TBL] [Abstract][Full Text] [Related]
3. Tenth value layers for 60Co gamma rays and for 4, 6, 10, 15, and 18 MV x rays in concrete for beams of cone angles between 0 degrees and 14 degrees calculated by Monte Carlo simulation.
Jaradat AK; Biggs PJ
Health Phys; 2007 May; 92(5):456-63. PubMed ID: 17429304
[TBL] [Abstract][Full Text] [Related]
4. Application of the diagnostic radiological index of protection to protective garments.
Pasciak AS; Jones AK; Wagner LK
Med Phys; 2015 Feb; 42(2):653-662. PubMed ID: 28102605
[TBL] [Abstract][Full Text] [Related]
5. Obliquity factors for 60 Co and 4, 10, and 18 MV x rays for concrete, steel, and lead and angles of incidence between 0 and 70 degrees.
Biggs PJ
Health Phys; 1996 Apr; 70(4):527-36. PubMed ID: 8617593
[TBL] [Abstract][Full Text] [Related]
6. Scattered fractions of dose from 6,10,18, and 25 MV linear accelerator x rays in radiotherapy facilities.
Shobe J; Rodgers JE; Taylor PL
Health Phys; 1999 Jan; 76(1):27-35. PubMed ID: 9883944
[TBL] [Abstract][Full Text] [Related]
7. [Air kerma transmission factors of Scattered X-rays in the maze of a Linac room for lead shield].
Kato H
Nihon Hoshasen Gijutsu Gakkai Zasshi; 2005 Jan; 61(1):96-103. PubMed ID: 15682037
[TBL] [Abstract][Full Text] [Related]
8. Radiation protection measurements around a 12 MeV mobile dedicated IORT accelerator.
Soriani A; Felici G; Fantini M; Paolucci M; Borla O; Evangelisti G; Benassi M; Strigari L
Med Phys; 2010 Mar; 37(3):995-1003. PubMed ID: 20384235
[TBL] [Abstract][Full Text] [Related]
9. Analysis of tenth-value-layers for common shielding materials for a robotically mounted stereotactic radiosurgery machine.
Rodgers JE
Health Phys; 2007 Apr; 92(4):379-86. PubMed ID: 17351503
[TBL] [Abstract][Full Text] [Related]
10. The spectrum and angular distribution of x rays scattered from a water phantom.
Cheng CW; Taylor KW; Holloway AF
Med Phys; 1995 Aug; 22(8):1235-45. PubMed ID: 7476709
[TBL] [Abstract][Full Text] [Related]
11. Scatter fractions from linear accelerators with x-ray energies from 6 to 24 MV.
Taylor PL; Rodgers JE; Shobe J
Med Phys; 1999 Aug; 26(8):1442-6. PubMed ID: 10501042
[TBL] [Abstract][Full Text] [Related]
12. Measurement of scatter factors for 4, 6, 10, and 23 MV x rays at scattering angles between 30 degrees and 135 degrees.
Nogueira IP; Biggs PJ
Health Phys; 2001 Sep; 81(3):330-40. PubMed ID: 11513466
[TBL] [Abstract][Full Text] [Related]
13. Build-up and surface dose measurements on phantoms using micro-MOSFET in 6 and 10 MV x-ray beams and comparisons with Monte Carlo calculations.
Xiang HF; Song JS; Chin DW; Cormack RA; Tishler RB; Makrigiorgos GM; Court LE; Chin LM
Med Phys; 2007 Apr; 34(4):1266-73. PubMed ID: 17500458
[TBL] [Abstract][Full Text] [Related]
14. Characteristics of bremsstrahlung in electron beams.
Zhu TC; Das IJ; Bjärngard BE
Med Phys; 2001 Jul; 28(7):1352-8. PubMed ID: 11488565
[TBL] [Abstract][Full Text] [Related]
15. Calculation of shielding door thicknesses for radiation therapy facilities using the ITS Monte Carlo program.
Biggs PJ
Health Phys; 1991 Oct; 61(4):465-72. PubMed ID: 1917483
[TBL] [Abstract][Full Text] [Related]
16. A Monte Carlo study of the energy spectra and transmission characteristics of scattered radiation from x-ray computed tomography.
Platten DJ
J Radiol Prot; 2014 Jun; 34(2):445-56. PubMed ID: 24894101
[TBL] [Abstract][Full Text] [Related]
17. Monte Carlo studies of x-ray scattering in transmission diagnostic radiology.
Barnea G; Dick CE
Med Phys; 1986; 13(4):490-5. PubMed ID: 3736507
[TBL] [Abstract][Full Text] [Related]
18. Albedos for 4-, 10-, and 18-MV bremsstrahlung x-ray beams on concrete, iron, and lead--normally incident.
Lo YC
Med Phys; 1992; 19(3):659-66. PubMed ID: 1324391
[TBL] [Abstract][Full Text] [Related]
19. Angular dependence of the response of the nanoDot OSLD system for measurements at depth in clinical megavoltage beams.
Lehmann J; Dunn L; Lye JE; Kenny JW; Alves AD; Cole A; Asena A; Kron T; Williams IM
Med Phys; 2014 Jun; 41(6):061712. PubMed ID: 24877807
[TBL] [Abstract][Full Text] [Related]
20. An investigation of backscatter factors for kilovoltage x-rays: a comparison between Monte Carlo simulations and Gafchromic EBT film measurements.
Kim J; Hill R; Claridge Mackonis E; Kuncic Z
Phys Med Biol; 2010 Feb; 55(3):783-97. PubMed ID: 20071763
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]