These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

85 related articles for article (PubMed ID: 12149991)

  • 1. [Volumetric pumps for blood transfusions. Viability in pediatrics].
    Tomás Rojas J; Burdallo Heras F; Sánchez García MR; Perea-Milla López E; Medina Vilchez MC; Díaz Rodríguez J
    Rev Enferm; 2001 Nov; 24(11):8-12. PubMed ID: 12149991
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Changes in red blood cell integrity related to infusion pumps: a comparison of three different pump mechanisms.
    Frey B; Eber S; Weiss M
    Pediatr Crit Care Med; 2003 Oct; 4(4):465-70. PubMed ID: 14525644
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Infusion pump-mediated mechanical hemolysis in pediatric patients.
    Hughes J; McNaughton J; Andrews J; George T; Bergero C; Pyke-Grimm K; Galel SA; Gonzalez C; Goodnough LT; Fontaine MJ
    Ann Clin Lab Sci; 2015; 45(2):140-7. PubMed ID: 25887866
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Hemolysis risk after packed red blood cells transfusion with infusion pumps.
    Wilson AMMM; Peterlini MAS; Pedreira MDLG
    Rev Lat Am Enfermagem; 2018 Oct; 26():e3053. PubMed ID: 30328976
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Feasibility of red blood cell transfusion through small bore central venous catheters used in neonates.
    Wong EC; Schreiber S; Criss VR; LaFleur B; Rais-Bahrami K; Short B; Luban NL
    Pediatr Crit Care Med; 2004 Jan; 5(1):69-74. PubMed ID: 14697112
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Effect of an infusion device on the integrity of whole blood and packed red blood cells.
    Burch KJ; Phelps SJ; Constance TD
    Am J Hosp Pharm; 1991 Jan; 48(1):92-7. PubMed ID: 2000884
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Effects of intravenous delivery systems on infused red blood cells.
    Gibson JS; Leff RD; Roberts RJ
    Am J Hosp Pharm; 1984 Mar; 41(3):468-72. PubMed ID: 6702849
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Neonatal Transfusion Practice: Hemolysis Markers After In Vitro Infusion of Packed Red Blood Cells by the Gravitational Method or Syringe Pump in a Peripheral Catheter.
    Orsi KCSC; Kita VY; de Souza AHP; Tsunemi MH; Avelar AFM
    J Perinat Neonatal Nurs; 2021 Oct-Dec 01; 35(4):E40-E49. PubMed ID: 34726655
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Levels of Hemolysis Markers in Erythrocyte Concentrates Administered Using a Syringe Infusion Pump.
    Gannam FF; Belela-Anacleto ASC; Kusahara DM; Gonçalves Pedreira M
    J Infus Nurs; 2018; 41(3):180-188. PubMed ID: 29659466
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Evaluation of IVAC Variable Pressure Volumetric Pump Model 560 for the delivery of red blood cells, adenine-saline added.
    Gurdak RG; Anderson G; Mintz PD
    Am J Clin Pathol; 1989 Feb; 91(2):199-202. PubMed ID: 2916463
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Red cell damage after pumping by two infusion control devices (Arcomed VP 7000 and IVAC 572).
    Parfitt HS; Davies SV; Tighe P; Ewings P
    Transfus Med; 2007 Aug; 17(4):290-5. PubMed ID: 17680955
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Impact of different syringe pumps on red cells during paediatric simulated transfusion.
    Pardo LP; Peterlini MAS; Tume LN; Pedreira MLG
    Nurs Crit Care; 2022 Mar; 27(2):267-274. PubMed ID: 33094901
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Effect of different pump mechanisms on transfusion of blood.
    Denison M; U P; Bell R; Schuldreich R; Chaudhri MA
    Australas Phys Eng Sci Med; 1991 Mar; 14(1):39-41. PubMed ID: 2029240
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Improving patient outcomes: transfusion with infusion pump for peripherally inserted central catheters and other vascular access devices.
    Houck D; Whiteford J
    J Infus Nurs; 2007; 30(6):341-4. PubMed ID: 18025981
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Effect on the quality of blood components after simulated blood transfusions using volumetric infusion pumps.
    Lieshout-Krikke RW; van der Meer PF; Koopman MM; de Korte D
    Transfusion; 2011 Aug; 51(8):1835-9. PubMed ID: 21303369
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Evaluation of a volumetric intravenous fluid infusion pump for transfusion of blood components containing red cells.
    Thompson HW; Lasky LC; Polesky HF
    Transfusion; 1986; 26(3):290-2. PubMed ID: 3705149
    [TBL] [Abstract][Full Text] [Related]  

  • 17. In vitro and in vivo evaluation of platelet transfusions administered through an electromechanical infusion pump.
    Snyder EL; Rinder HM; Napychank P
    Am J Clin Pathol; 1990 Jul; 94(1):77-80. PubMed ID: 2360566
    [TBL] [Abstract][Full Text] [Related]  

  • 18. The effects of pressure and flow on hemolysis caused by Bio-Medicus centrifugal pumps and roller pumps. Guidelines for choosing a blood pump.
    Tamari Y; Lee-Sensiba K; Leonard EF; Parnell V; Tortolani AJ
    J Thorac Cardiovasc Surg; 1993 Dec; 106(6):997-1007. PubMed ID: 8246582
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Mechanical damage of red blood cells by rotary blood pumps: selective destruction of aged red blood cells and subhemolytic trauma.
    Sakota D; Sakamoto R; Sobajima H; Yokoyama N; Waguri S; Ohuchi K; Takatani S
    Artif Organs; 2008 Oct; 32(10):785-91. PubMed ID: 18959667
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Does the use of infusion pumps increase hemolysis during blood transfusion in patients with thalassemia?
    Turgutoğlu Yılmaz A; Gürlek Gökçebay D; Yılmaz N; Neşelioğlu S; Çulha V; Erel Ö; Yaralı N; Özbek NY
    Transfus Apher Sci; 2023 Jun; 62(3):103623. PubMed ID: 36526531
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 5.