These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

154 related articles for article (PubMed ID: 12153880)

  • 1. Assessment of stroke index using impedance cardiography: comparison with traditional vital signs for detection of moderate acute blood loss in healthy volunteers.
    Kosowsky JM; Han JH; Collins SP; McAfee AT; Storrow AB
    Acad Emerg Med; 2002 Aug; 9(8):775-80. PubMed ID: 12153880
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Evaluation of the use of shock index in identifying acute blood loss in healthy blood donor dogs.
    McGowan EE; Marryott K; Drobatz KJ; Reineke EL
    J Vet Emerg Crit Care (San Antonio); 2017 Sep; 27(5):524-531. PubMed ID: 28795781
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Use of Shock Index to Identify Mild Hemorrhage: An Observational Study in Military Blood Donors.
    Pasquier P; Duron S; Pouget T; Carbonnel AC; Boutonnet M; Malgras B; Barbier O; de Saint Maurice G; Sailliol A; Ausset S; Martinaud C
    Prehosp Disaster Med; 2019 Jun; 34(3):303-307. PubMed ID: 31030706
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Changes in stroke index measured by impedance cardiography in a human model of moderate acute blood loss.
    Kosowsky JM; Collins SP; Han J; Gasaway MD; Storrow AB
    Acad Emerg Med; 2000 Oct; 7(10):1167-8. PubMed ID: 11015264
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Shock index in diagnosing early acute hypovolemia.
    Birkhahn RH; Gaeta TJ; Terry D; Bove JJ; Tloczkowski J
    Am J Emerg Med; 2005 May; 23(3):323-6. PubMed ID: 15915406
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Detection of low-volume blood loss: compensatory reserve versus traditional vital signs.
    Stewart CL; Mulligan J; Grudic GZ; Convertino VA; Moulton SL
    J Trauma Acute Care Surg; 2014 Dec; 77(6):892-7; discussion 897-8. PubMed ID: 25423536
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Prediction of Massive Transfusion in Trauma Patients with Shock Index, Modified Shock Index, and Age Shock Index.
    Rau CS; Wu SC; Kuo SC; Pao-Jen K; Shiun-Yuan H; Chen YC; Hsieh HY; Hsieh CH; Liu HT
    Int J Environ Res Public Health; 2016 Jul; 13(7):. PubMed ID: 27399737
    [TBL] [Abstract][Full Text] [Related]  

  • 8. [Correlation between shock index and diastolic blood pressure in patients with postpartum hemorrhage and early warning of postpartum hemorrhage risk: an analysis of numerous cases in 4 years].
    Zu D; Zhuge Y
    Zhonghua Wei Zhong Bing Ji Jiu Yi Xue; 2018 Oct; 30(10):959-963. PubMed ID: 30439317
    [TBL] [Abstract][Full Text] [Related]  

  • 9. A comparison of base deficit and vital signs in the early assessment of patients with penetrating trauma in a high burden setting.
    Dunham MP; Sartorius B; Laing GL; Bruce JL; Clarke DL
    Injury; 2017 Sep; 48(9):1972-1977. PubMed ID: 28684079
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Trends of Hemoglobin Oximetry: Do They Help Predict Blood Transfusion During Trauma Patient Resuscitation?
    Yang S; Hu PF; Anazodo A; Gao C; Chen H; Wade C; Hartsky L; Miller C; Imle C; Fang R; Mackenzie CF
    Anesth Analg; 2016 Jan; 122(1):115-25. PubMed ID: 26683104
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Cushing's Disease: Assessment of Early Cardiovascular Hemodynamic Dysfunction With Impedance Cardiography.
    Jurek A; Krzesiński P; Gielerak G; Witek P; Zieliński G; Kazimierczak A; Wierzbowski R; Banak M; Uziębło-Życzkowska B
    Front Endocrinol (Lausanne); 2021; 12():751743. PubMed ID: 34659130
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Reliability and precision of a new thoracic electrical bioimpedance monitor in a lower body negative pressure model.
    Sageman WS
    Crit Care Med; 1999 Sep; 27(9):1986-90. PubMed ID: 10507629
    [TBL] [Abstract][Full Text] [Related]  

  • 13. The value of traditional vital signs, shock index, and age-based markers in predicting trauma mortality.
    Bruijns SR; Guly HR; Bouamra O; Lecky F; Lee WA
    J Trauma Acute Care Surg; 2013 Jun; 74(6):1432-7. PubMed ID: 23694869
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Continuous non-invasive measurement of stroke volume and cardiac index in infants and children: comparison of Impedance Cardiography NICaS® vs CardioQ® method.
    Beck R; Milella L; Labellarte C
    Clin Ter; 2018; 169(3):e110-e113. PubMed ID: 29938742
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Use of stroke distance in the early detection of simulated blood loss.
    Hanson JM; Van Hoeyweghen R; Kirkman E; Thomas A; Horan MA
    J Trauma; 1998 Jan; 44(1):128-34. PubMed ID: 9464760
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Muscle Oxygen Saturation Improves Diagnostic Association Between Initial Vital Signs and Major Hemorrhage: A Prospective Observational Study.
    Reisner AT; Edla S; Liu J; Rubin JT; Thorsen JE; Kittell E; Smith JB; Yeh DD; Reifman J
    Acad Emerg Med; 2016 Mar; 23(3):353-7. PubMed ID: 26743804
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Bioelectric impedance predicts total body water, blood pressure, and heart rate during hemodialysis in children and adolescents.
    Brooks ER; Fatallah-Shaykh SA; Langman CB; Wolf KM; Price HE
    J Ren Nutr; 2008 May; 18(3):304-11. PubMed ID: 18410888
    [TBL] [Abstract][Full Text] [Related]  

  • 18. The value of noninvasive measurement of the compensatory reserve index in monitoring and triage of patients experiencing minimal blood loss.
    Nadler R; Convertino VA; Gendler S; Lending G; Lipsky AM; Cardin S; Lowenthal A; Glassberg E
    Shock; 2014 Aug; 42(2):93-8. PubMed ID: 24667628
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Shock index and delta-shock index are superior to existing maternal early warning criteria to identify postpartum hemorrhage and need for intervention.
    Kohn JR; Dildy GA; Eppes CS
    J Matern Fetal Neonatal Med; 2019 Apr; 32(8):1238-1244. PubMed ID: 29113517
    [TBL] [Abstract][Full Text] [Related]  

  • 20. [Value of heart rate-blood pressure product of multiplication for identifying compensated shock in children].
    Ge HY; Liu S; Zhang J; Hui Y; Gao WP; Sun YY; Shi C; Qu D
    Zhonghua Er Ke Za Zhi; 2021 Dec; 59(12):1074-1079. PubMed ID: 34856667
    [No Abstract]   [Full Text] [Related]  

    [Next]    [New Search]
    of 8.