These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

116 related articles for article (PubMed ID: 12167803)

  • 1. Thrombotic occlusion of the aortic ostia of saphenous venous grafts early after coronary artery bypass grafting by using the Symmetry aortic connector system.
    Donsky AS; Schussler JM; Donsky MS; Roberts WC; Hamman BL
    J Thorac Cardiovasc Surg; 2002 Aug; 124(2):397-9. PubMed ID: 12167803
    [No Abstract]   [Full Text] [Related]  

  • 2. [Clinical experience with aortic connector system].
    Moriyama H; Tomita S; Tabata S; Nagamine H; Arai S; Takemura H; Watanabe G
    Kyobu Geka; 2005 Feb; 58(2):89-92; discussion 92-5. PubMed ID: 15724468
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Minimizing aortic manipulation during OPCAB using the symmetry aortic connector system for proximal vein graft anastomoses.
    Eckstein FS; Bonilla LF; Englberger L; Stauffer E; Berg TA; Schmidli J; Carrel TP
    Ann Thorac Surg; 2001 Sep; 72(3):S995-8. PubMed ID: 11565735
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Pitfalls and key lessons with the symmetry proximal anastomotic device in coronary artery bypass surgery.
    Carrel TP; Eckstein FS; Englberger L; Windecker S; Meier B
    Ann Thorac Surg; 2003 May; 75(5):1434-6. PubMed ID: 12735558
    [TBL] [Abstract][Full Text] [Related]  

  • 5. The St Jude Medical symmetry aortic connector system for proximal vein graft anastomoses in coronary artery bypass grafting.
    Eckstein FS; Bonilla LF; Englberger L; Immer FF; Berg TA; Schmidli J; Carrel TP
    J Thorac Cardiovasc Surg; 2002 Apr; 123(4):777-82. PubMed ID: 11986606
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Use of an aortic connector system for vein grafting: intermediate outcomes.
    Inaba H; Higuchi K; Koseni K; Yamauchi H; Naganuma J
    Jpn J Thorac Cardiovasc Surg; 2005 Nov; 53(11):587-92. PubMed ID: 16363715
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Fatal complications after use of the Symmetry Aortic Connector in coronary artery bypass surgery.
    Lahtinen J; Biancari F; Mosorin M; Heikkinen J; Rainio P; Juvonen TS; Lepojärvi M
    Ann Thorac Surg; 2004 May; 77(5):1817-9. PubMed ID: 15111196
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Intraoperative and intermediate-term angiographic results of coronary artery bypass surgery with Symmetry proximal anastomotic device.
    Bergsland J; Hol PK; Lingås PS; Lundblad R; Rein KA; Andersen R; Mørk BE; Halvorsen S; Mujanovic E; Kabil E; Svennevig JL; Fosse E
    J Thorac Cardiovasc Surg; 2004 Nov; 128(5):718-23. PubMed ID: 15514599
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Angiographic results after the use of a sutureless aortic connector for proximal vein graft anastomoses.
    Wiklund L; Bugge M; Berglin E
    Ann Thorac Surg; 2002 Jun; 73(6):1993-4. PubMed ID: 12078820
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Forty-one-month follow-up of the Symmetry aortic connector system for proximal venous anastomosis.
    Bergmann P; Meszaros K; Huber S; Oberwalder P; Mächler H; Schaffler G; Rienmueller R; Rigler B
    J Thorac Cardiovasc Surg; 2007 Jul; 134(1):23-8. PubMed ID: 17599482
    [TBL] [Abstract][Full Text] [Related]  

  • 11. eComment: Aortic connectors in coronary artery surgery.
    Ricci M; Salerno TA
    Interact Cardiovasc Thorac Surg; 2008 Aug; 7(4):672. PubMed ID: 18664671
    [No Abstract]   [Full Text] [Related]  

  • 12. First experience with the St Jude Medical, Inc, Symmetry Bypass System (Aortic Connector System).
    Hornik L; Tenderich G; Minami K; Fassbender D; Schulz TO; Beinert B; Koerfer R
    J Thorac Cardiovasc Surg; 2003 Feb; 125(2):414-7. PubMed ID: 12579116
    [No Abstract]   [Full Text] [Related]  

  • 13. Mid-term follow up of patients using the St. Jude Medical Aortic Connector System for proximal vein graft in CABG.
    Chung CH; Lee JW; Kang JK; Song H; Choo SJ; Song MG
    J Korean Med Sci; 2006 Oct; 21(5):849-53. PubMed ID: 17043418
    [TBL] [Abstract][Full Text] [Related]  

  • 14. The second-generation aortic connector: six months' angiographic follow-up.
    Setina M; Krchnakova A; Mokracek A; Pesl L; Bonilla LF
    Ann Thorac Surg; 2005 Aug; 80(2):695-9. PubMed ID: 16039230
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Initial experience with sutureless proximal anastomoses performed with a mechanical connector leading to clampless off-pump coronary artery bypass surgery.
    Katariya K; Yassin S; Tehrani HY; Lombardi P; Masroor S; Salerno TA
    Ann Thorac Surg; 2004 Feb; 77(2):563-7; discussion 567-8. PubMed ID: 14759438
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Early and midterm patency of the proximal anastomoses of saphenous vein grafts made with a Symmetry Aortic Connector System.
    Kitamura H; Okabayashi H; Hanyu M; Soga Y; Nomoto T; Johno H; Nakano J; Matsuo T; Kai M; Umehara E
    J Thorac Cardiovasc Surg; 2005 Oct; 130(4):1028-31. PubMed ID: 16214515
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Clinical experience with the CorLink device for proximal anastomosis of the saphenous vein to the aorta: a clinical, prospective, and randomized study.
    Riess FC; Helmold H; Hilfer I; Bader R; Stripling J; Loewer C; Wesner F; Bleese N
    Heart Surg Forum; 2002; 5(4):345-53. PubMed ID: 12538116
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Video-assisted multivessel revascularization through a left anterior small thoracotomy approach with the Symmetry Aortic Connector System.
    Semrád M; Bodlák P; Stríteský M; Vondrácek V; Urban T; Vyhnalová P; Holm F; Vanek I
    J Thorac Cardiovasc Surg; 2003 Jan; 125(1):129-34. PubMed ID: 12538996
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Occlusion of saphenous vein aorto-coronary grafts. Case report of early total occlusion at the site of aortic anastomosis.
    Edelstein J; Krall J; Lopez E
    Ohio State Med J; 1973 Aug; 69(8):618-20. PubMed ID: 4542408
    [No Abstract]   [Full Text] [Related]  

  • 20. Early clinical results of St. Jude Medical Symmetry aortic connector.
    Toyama M; Usui A; Abe T; Yoshikawa M; Akita T; Ueda Y
    J Artif Organs; 2005; 8(2):95-9. PubMed ID: 16094513
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.