These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

129 related articles for article (PubMed ID: 12176444)

  • 1. Usefulness of cooling perfusion apparatus in cadaveric kidney perfusion.
    Hattori R; Ono Y; Fukuhara N; Katoh M; Ohshima S; Kinoshita Y; Nimura H
    Transplant Proc; 2002 Aug; 34(5):1469-72. PubMed ID: 12176444
    [No Abstract]   [Full Text] [Related]  

  • 2. New pulsatile perfusion method for non-heart-beating cadaveric donor organs: a preliminary report.
    Yland MJ; Anaise D; Ishimaru M; Rapaport FT
    Transplant Proc; 1993 Dec; 25(6):3087-90. PubMed ID: 8266463
    [No Abstract]   [Full Text] [Related]  

  • 3. Usefulness of machine perfusion preservation for non-heart-beating donors in kidney transplantation.
    Matsuno N; Sakurai E; Uchiyama M; Kozaki K; Miyamoto K; Kozaki M
    Transplant Proc; 1996 Jun; 28(3):1551-2. PubMed ID: 8658781
    [No Abstract]   [Full Text] [Related]  

  • 4. Need for a systematic approach to organ recovery: technology development for the non-heart-beating donor.
    Brockbank KG; Taylor MJ; Owen DR
    Transplant Proc; 2000 Feb; 32(1):97-9. PubMed ID: 10700983
    [No Abstract]   [Full Text] [Related]  

  • 5. Retro-peritoneal cooling for kidney preservation from multi-organ cadaver donors.
    Salazar-Bañuelos A; Monroy-Cuadros M; Henriquez-Cooper H
    Am J Surg; 2018 May; 215(5):802-803. PubMed ID: 29317046
    [TBL] [Abstract][Full Text] [Related]  

  • 6. A protocol for rat kidney normothermic machine perfusion and subsequent transplantation.
    Czogalla J; Grahammer F; Puelles VG; Huber TB
    Artif Organs; 2021 Feb; 45(2):168-174. PubMed ID: 32780541
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Usefulness of continuous hypothermic perfusion preservation for cadaveric renal grafts in poor condition.
    Kozaki K; Sakurai E; Tamaki I; Matsuno N; Saito A; Furuhashi K; Uchiyama M; Zhang S; Kozaki M
    Transplant Proc; 1995 Feb; 27(1):757-8. PubMed ID: 7879173
    [No Abstract]   [Full Text] [Related]  

  • 8. Combined intravascular and intraperitoneal cooling in the non-heart-beating donor improves kidney function following transplantation.
    Light JA; Sasaki TM; Aquino AO; Barhyte DY; Gage F
    Transplant Proc; 2000 Feb; 32(1):188. PubMed ID: 10701017
    [No Abstract]   [Full Text] [Related]  

  • 9. Non-heart-beating donor transplantation: machine perfusion preservation is the answer to prolonged cold ischemia time.
    Rizvi SA
    Transplant Proc; 2000 Feb; 32(1):143. PubMed ID: 10701000
    [No Abstract]   [Full Text] [Related]  

  • 10. Use of in situ cooling and machine perfusion preservation for non-heart-beating donors.
    Matsuno N; Sakurai E; Uchiyama M; Kozaki K; Tamaki I; Kozaki M
    Transplant Proc; 1993 Dec; 25(6):3095-6. PubMed ID: 8266466
    [No Abstract]   [Full Text] [Related]  

  • 11. In situ renal cooling for kidney transplantation from non-heart-beating donors.
    Kato M; Mizutani K; Hattori R; Kinukawa T; Uchida K; Hoshinaga K; Ono Y; Ohshima S
    Transplant Proc; 2000 Nov; 32(7):1608-10. PubMed ID: 11119858
    [No Abstract]   [Full Text] [Related]  

  • 12. Gravity perfusion versus high-pressure perfusion in kidney transplantation: results from a prospective randomized study.
    Tisone G; Orlando G; Pisani F; Iaria G; Negrini S; Pollicita S; Strati F; Nanni G; Castagneto M; Casciani CU
    Transplant Proc; 1999 Dec; 31(8):3386-7. PubMed ID: 10616517
    [No Abstract]   [Full Text] [Related]  

  • 13. Rapid in vivo multiple organ cooling prior to harvesting.
    Toledo-Pereyra LH
    Am Surg; 1984 Sep; 50(9):493-5. PubMed ID: 6383160
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Procurement and preservation of cadaver kidneys.
    Barry JM
    Urol Clin North Am; 1983 May; 10(2):205-16. PubMed ID: 6344384
    [No Abstract]   [Full Text] [Related]  

  • 15. Perfusion of a Kidney Graft From a Donor After Cardiac Death Based on Immediately Started Pulsatile Machine Perfusion-An Experimental Study on a Small Animal.
    Opatrný V; Moláček J; Třeška V; Matějka R; Hes O
    Transplant Proc; 2018 Jun; 50(5):1544-1548. PubMed ID: 29880384
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Effectiveness of machine perfusion preservation as a viability determination method for kidneys procured from non-heart-beating donors.
    Matsuno N; Sakurai E; Tamaki I; Furuhashi K; Saito A; Zhang S; Kozaki K; Shimada A; Miyamoto K; Kozaki M
    Transplant Proc; 1994 Aug; 26(4):2421-2. PubMed ID: 8066794
    [No Abstract]   [Full Text] [Related]  

  • 17. Prediction of kidney nonfunction after transplantation with machine perfusion preservation.
    Kozaki K; Sakurai E; Kubota K; Iwamoto H; Hama K; Narumi Y; Uchiyama M; Kikuchi K; Degawa H; Matsuno N; Kozaki M; Nagao T
    Transplant Proc; 2000 Mar; 32(2):275-6. PubMed ID: 10715415
    [No Abstract]   [Full Text] [Related]  

  • 18. Usefulness of continuous hypothermic perfusion preservation for renal grafts from non-heart-beating donors with prolonged warm ischemia time.
    Kozaki K; Uchiyama M; Nemoto T; Degawa H; Matsuno N; Sakurai E; Kozaki M; Nagao T
    Transplant Proc; 1997 Dec; 29(8):3586-7. PubMed ID: 9414848
    [No Abstract]   [Full Text] [Related]  

  • 19. In situ preservation of cadaver kidneys for transplantation: laboratory observations and clinical application.
    Garcia-Rinaldi R; Lefrak EA; Defore WW; Feldman L; Noon GP; Jachimczyk JA; DeBakey ME
    Ann Surg; 1975 Nov; 182(5):576-84. PubMed ID: 1103757
    [TBL] [Abstract][Full Text] [Related]  

  • 20. The effect of machine perfusion preservation on early function of non-heart-beating donor kidneys.
    Daemen JH; de Vries B; Kootstra G
    Transplant Proc; 1997 Dec; 29(8):3489. PubMed ID: 9414806
    [No Abstract]   [Full Text] [Related]  

    [Next]    [New Search]
    of 7.