1. Benefit of simultaneous recording of EEG and MEG in dipole localization.
Yoshinaga H; Nakahori T; Ohtsuka Y; Oka E; Kitamura Y; Kiriyama H; Kinugasa K; Miyamoto K; Hoshida T
Epilepsia; 2002 Aug; 43(8):924-8. PubMed ID: 12181013
[TBL] [Abstract][Full Text] [Related]
2. Magnetoencephalographic Identification of Epileptic Focus in Children With Generalized Electroencephalographic (EEG) Features but Focal Imaging Abnormalities.
Shukla G; Kazutaka J; Gupta A; Mosher J; Jones S; Alexopoulos A; Burgess RC
J Child Neurol; 2017 Oct; 32(12):981-995. PubMed ID: 28828916
[TBL] [Abstract][Full Text] [Related]
3. MEG versus EEG: influence of background activity on interictal spike detection.
Ramantani G; Boor R; Paetau R; Ille N; Feneberg R; Rupp A; Boppel T; Scherg M; Rating D; Bast T
J Clin Neurophysiol; 2006 Dec; 23(6):498-508. PubMed ID: 17143138
[TBL] [Abstract][Full Text] [Related]
4. High-resolution source imaging in mesiotemporal lobe epilepsy: a comparison between MEG and simultaneous EEG.
Leijten FS; Huiskamp GJ; Hilgersom I; Van Huffelen AC
J Clin Neurophysiol; 2003; 20(4):227-38. PubMed ID: 14530735
[TBL] [Abstract][Full Text] [Related]
5. Preoperative simulation of intracerebral epileptiform discharges: synthetic aperture magnetometry virtual sensor analysis of interictal magnetoencephalography data.
Oishi M; Otsubo H; Iida K; Suyama Y; Ochi A; Weiss SK; Xiang J; Gaetz W; Cheyne D; Chuang SH; Rutka JT; Snead OC
J Neurosurg; 2006 Jul; 105(1 Suppl):41-9. PubMed ID: 16871869
[TBL] [Abstract][Full Text] [Related]
6. Ictal magnetoencephalography in temporal and extratemporal lobe epilepsy.
Assaf BA; Karkar KM; Laxer KD; Garcia PA; Austin EJ; Barbaro NM; Aminoff MJ
Epilepsia; 2003 Oct; 44(10):1320-7. PubMed ID: 14510826
[TBL] [Abstract][Full Text] [Related]
7. Detection of epileptiform activity by human interpreters: blinded comparison between electroencephalography and magnetoencephalography.
Iwasaki M; Pestana E; Burgess RC; Lüders HO; Shamoto H; Nakasato N
Epilepsia; 2005 Jan; 46(1):59-68. PubMed ID: 15660769
[TBL] [Abstract][Full Text] [Related]
8. Magnetoencephalography is more successful for screening and localizing frontal lobe epilepsy than electroencephalography.
Ossenblok P; de Munck JC; Colon A; Drolsbach W; Boon P
Epilepsia; 2007 Nov; 48(11):2139-49. PubMed ID: 17662061
[TBL] [Abstract][Full Text] [Related]
9. EEG and MEG source analysis of single and averaged interictal spikes reveals intrinsic epileptogenicity in focal cortical dysplasia.
Bast T; Oezkan O; Rona S; Stippich C; Seitz A; Rupp A; Fauser S; Zentner J; Rating D; Scherg M
Epilepsia; 2004 Jun; 45(6):621-31. PubMed ID: 15144427
[TBL] [Abstract][Full Text] [Related]
10. Localization of abnormal discharges causing insular epilepsy by magnetoencephalography.
Park HM; Nakasato N; Tominaga T
Tohoku J Exp Med; 2012 Mar; 226(3):207-11. PubMed ID: 22353789
[TBL] [Abstract][Full Text] [Related]
11. Combined MEG/EEG analysis of the interictal spike complex in mesial temporal lobe epilepsy.
Pataraia E; Lindinger G; Deecke L; Mayer D; Baumgartner C
Neuroimage; 2005 Feb; 24(3):607-14. PubMed ID: 15652296
[TBL] [Abstract][Full Text] [Related]
12. Magnetic source imaging for the surgical evaluation of electroencephalography-confirmed secondary bilateral synchrony in intractable epilepsy.
Chang EF; Nagarajan SS; Mantle M; Barbaro NM; Kirsch HE
J Neurosurg; 2009 Dec; 111(6):1248-56. PubMed ID: 19575574
[TBL] [Abstract][Full Text] [Related]
13. Simultaneous magnetoencephalography and intracranial EEG registration: technical and clinical aspects.
Santiuste M; Nowak R; Russi A; Tarancon T; Oliver B; Ayats E; Scheler G; Graetz G
J Clin Neurophysiol; 2008 Dec; 25(6):331-9. PubMed ID: 18997623
[TBL] [Abstract][Full Text] [Related]
14. Magnetoencephalographic spikes with small spikes on simultaneous electroencephalography have high spatial clustering in temporal lobe epilepsy.
Okamura A; Iida K; Hashizume A; Kagawa K; Seyama G; Horie N
Epilepsy Res; 2023 May; 192():107127. PubMed ID: 36963303
[TBL] [Abstract][Full Text] [Related]
15. Comparison of electroencephalographic dipoles of interictal spikes from prolonged scalp video-electroencephalography and magnetoencephalographic dipoles from short-term recording in children with extratemporal lobe epilepsy.
Ochi A; Otsubo H; Sharma R; Hunjan A; Rutka JT; Chuang SH; Kamijo K; Yamazaki T; Quint P; Kurelowech L; Sobel DF; Aung MH; Snead OC
J Child Neurol; 2001 Sep; 16(9):661-7. PubMed ID: 11575607
[TBL] [Abstract][Full Text] [Related]
16. Sensitivity of scalp 10-20 EEG and magnetoencephalography.
Kakisaka Y; Alkawadri R; Wang ZI; Enatsu R; Mosher JC; Dubarry AS; Alexopoulos AV; Burgess RC
Epileptic Disord; 2013 Mar; 15(1):27-31. PubMed ID: 23531601
[TBL] [Abstract][Full Text] [Related]
17. Advantageous information provided by magnetoencephalography for patients with neocortical epilepsy.
Ito T; Otsubo H; Shiraishi H; Yagyu K; Takahashi Y; Ueda Y; Takeuchi F; Takahashi K; Nakane S; Kohsaka S; Saitoh S
Brain Dev; 2015 Feb; 37(2):237-42. PubMed ID: 24819913
[TBL] [Abstract][Full Text] [Related]
18. Magnetoencephalographic studies of focal epileptic activity in three patients with epilepsy suggestive of Lennox-Gastaut syndrome.
Sakurai K; Tanaka N; Kamada K; Takeuchi F; Takeda Y; Koyama T
Epileptic Disord; 2007 Jun; 9(2):158-63. PubMed ID: 17525026
[TBL] [Abstract][Full Text] [Related]
19. Magnetoencephalography to confirm epileptiform discharges mimicking small sharp spikes in temporal lobe epilepsy.
Agari D; Jin K; Kakisaka Y; Kanno A; Ishida M; Kawashima R; Nakasato N
Clin Neurophysiol; 2021 Aug; 132(8):1785-1789. PubMed ID: 34130246
[TBL] [Abstract][Full Text] [Related]
20. Benign epileptiform discharges in Rolandic region with mesial temporal lobe epilepsy: MEG, scalp and intracranial EEG features.
RamachandranNair R; Ochi A; Benifla M; Rutka JT; Snead OC; Otsubo H
Acta Neurol Scand; 2007 Jul; 116(1):59-64. PubMed ID: 17587257
[TBL] [Abstract][Full Text] [Related]