BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

233 related articles for article (PubMed ID: 12181468)

  • 1. Performance of the rapid plasma reagin and the rapid syphilis screening tests in the diagnosis of syphilis in field conditions in rural Africa.
    West B; Walraven G; Morison L; Brouwers J; Bailey R
    Sex Transm Infect; 2002 Aug; 78(4):282-5. PubMed ID: 12181468
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Evaluation of the rapid plasma reagin "teardrop" card test for screening of syphilis in field conditions.
    Van Dyck E; Van de Velden L; Ndoye I; Piot P; Meheus A
    Sex Transm Dis; 1993; 20(4):194-7. PubMed ID: 8211535
    [TBL] [Abstract][Full Text] [Related]  

  • 3. On-site rapid antenatal syphilis screening with an immunochromatographic strip improves case detection and treatment in rural South African clinics.
    Bronzan RN; Mwesigwa-Kayongo DC; Narkunas D; Schmid GP; Neilsen GA; Ballard RC; Karuhije P; Ddamba J; Nombekela E; Hoyi G; Dlali P; Makwedini N; Fehler HG; Blandford JM; Ryan C
    Sex Transm Dis; 2007 Jul; 34(7 Suppl):S55-60. PubMed ID: 17139234
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Field evaluation of simple rapid tests in the diagnosis of syphilis.
    Nessa K; Alam A; Chawdhury FA; Huq M; Nahar S; Salauddin G; Khursheed S; Rahman S; Gurley E; Breiman RF; Rahman M
    Int J STD AIDS; 2008 May; 19(5):316-20. PubMed ID: 18482961
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Challenges of Rapid Plasma Reagin Interpretation in Syphilis Screening in Uganda: Variability in Nontreponemal Results Between Different Laboratories.
    Hamill MM; Mbazira KJ; Kiragga AN; Gaydos CA; Jett-Goheen M; Parkes-Ratanshi R; Manabe YC; Nakku-Joloba E; Rompalo A
    Sex Transm Dis; 2018 Dec; 45(12):829-833. PubMed ID: 29944643
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Field efficiency of syphilis screening in antenatal care: lessons from Gutu District in Zimbabwe.
    Majoko F; Munjanja S; Nystrom L; Mason E; Lindmark G
    Cent Afr J Med; 2003; 49(7-8):90-3. PubMed ID: 15214281
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Diagnostic dilemma of the single screening test used in the diagnosis of syphilis in Nepal.
    Dumre SP; Shakya G; Acharya D; Malla S; Adhikari N
    Nepal Med Coll J; 2011 Dec; 13(4):238-40. PubMed ID: 23016470
    [TBL] [Abstract][Full Text] [Related]  

  • 8. What Is the Role of Paired Rapid Plasma Reagin Testing (Simultaneous Testing of Acute and Convalescent Samples) in the Diagnosis of Repeat Syphilis and the Follow-up of Syphilis?
    Kenyon CR; Osbak KK; Van Esbroek M; Lynen L; Crucitti T
    Sex Transm Dis; 2018 Jan; 45(1):35-38. PubMed ID: 28876300
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Rapid Syphilis Testing for Men Who Have Sex With Men in Outreach Settings: Evaluation of Test Performance and Impact on Time to Treatment.
    Obafemi OA; Wendel KA; Anderson TS; Scott TE; Rowan SE; Travanty EA; Rietmeijer CA
    Sex Transm Dis; 2019 Mar; 46(3):191-195. PubMed ID: 30363029
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Evaluation of a Rapid Syphilis Test in an Emergency Department Setting in Detroit, Michigan.
    Fakile YF; Markowitz N; Zhu W; Mumby K; Dankerlui D; McCormick JK; Ham DC; Hopkins A; Manteuffel J; Sun Y; Huang YA; Peters PJ; Hoover KW
    Sex Transm Dis; 2019 Jul; 46(7):429-433. PubMed ID: 30839394
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Comparison of the diagnostic accuracy of a rapid immunochromatographic test and the rapid plasma reagin test for antenatal syphilis screening in Mozambique.
    Montoya PJ; Lukehart SA; Brentlinger PE; Blanco AJ; Floriano F; Sairosse J; Gloyd S
    Bull World Health Organ; 2006 Feb; 84(2):97-104. PubMed ID: 16501726
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Comparison of an automated rapid plasma reagin (RPR) test with the conventional RPR card test in syphilis testing.
    Lee JH; Lim CS; Lee MG; Kim HS
    BMJ Open; 2014 Dec; 4(12):e005664. PubMed ID: 25552608
    [TBL] [Abstract][Full Text] [Related]  

  • 13. The laboratory impact of changing syphilis screening from the rapid-plasma reagin to a treponemal enzyme immunoassay: a case-study from the Greater Toronto Area.
    Mishra S; Boily MC; Ng V; Gold WL; Okura T; Shaw M; Mazzulli T; Fisman DN
    Sex Transm Dis; 2011 Mar; 38(3):190-6. PubMed ID: 20706176
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Characteristics of primary and late latent syphilis cases which were initially non-reactive with the rapid plasma reagin as the screening test.
    Singh AE; Wong T; De P
    Int J STD AIDS; 2008 Jul; 19(7):464-8. PubMed ID: 18574118
    [TBL] [Abstract][Full Text] [Related]  

  • 15. [Analysis of positive results in mediace rapid plasma reagin and Treponema pallidum latex agglutination as the automated syphilis test].
    Huh HJ; Lee KK; Kim ES; Chae SL
    Korean J Lab Med; 2007 Oct; 27(5):324-9. PubMed ID: 18094596
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Usefulness of Automated Latex Turbidimetric Rapid Plasma Reagin Test for Diagnosis and Evaluation of Treatment Response in Syphilis in Comparison with Manual Card Test: a Prospective Cohort Study.
    Tsuboi M; Nishijima T; Aoki T; Teruya K; Kikuchi Y; Gatanaga H; Oka S
    J Clin Microbiol; 2018 Nov; 56(11):. PubMed ID: 30135229
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Introduction of rapid tests for large-scale syphilis screening among female, male, and transgender sex workers in Mumbai, India.
    Gupte S; Daly C; Agarwal V; Gaikwad SB; George B
    Sex Transm Dis; 2011 Jun; 38(6):499-502. PubMed ID: 21183861
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Cost-effectiveness of a dual non-treponemal/treponemal syphilis point-of-care test to prevent adverse pregnancy outcomes in sub-Saharan Africa.
    Owusu-Edusei K; Gift TL; Ballard RC
    Sex Transm Dis; 2011 Nov; 38(11):997-1003. PubMed ID: 21992974
    [TBL] [Abstract][Full Text] [Related]  

  • 19. A retrospective study on rapid plasma reagin testing in patients with Pityriasis rosea.
    Halteh P; Lipner SR
    Int J STD AIDS; 2017 Nov; 28(13):1348-1351. PubMed ID: 28345391
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Predictive value of past and current screening tests for syphilis in blood donors: changing from a rapid plasma reagin test to an automated specific treponemal test for screening.
    Aberle-Grasse J; Orton SL; Notari E; Layug LP; Cable RG; Badon S; Popovsky MA; Grindon AJ; Lenes BA; Williams AE
    Transfusion; 1999 Feb; 39(2):206-11. PubMed ID: 10037133
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 12.