These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
132 related articles for article (PubMed ID: 12188477)
1. Failure of hydroxyapatite-coated acetabular cups. Ten-year follow-up of 85 Landos Atoll arthroplasties. Lai KA; Shen WJ; Chen CH; Yang CY; Hu WP; Chang GL J Bone Joint Surg Br; 2002 Jul; 84(5):641-6. PubMed ID: 12188477 [TBL] [Abstract][Full Text] [Related]
2. Does hydroxyapatite coating of uncemented cups improve long-term survival? An analysis of 28,605 primary total hip arthroplasty procedures from the Nordic Arthroplasty Register Association (NARA). Lazarinis S; Mäkelä KT; Eskelinen A; Havelin L; Hallan G; Overgaard S; Pedersen AB; Kärrholm J; Hailer NP Osteoarthritis Cartilage; 2017 Dec; 25(12):1980-1987. PubMed ID: 28802851 [TBL] [Abstract][Full Text] [Related]
3. Survival of hydroxyapatite-coated cups: acetabular screws involve a lower rate of revision surgery due to aseptic loosening. Natera L; Valera M; Gómez EM; Ibañez N; Crusi X; Sancho R Hip Int; 2017 Mar; 27(2):153-161. PubMed ID: 28165590 [TBL] [Abstract][Full Text] [Related]
4. Effects of hydroxyapatite coating of cups used in hip revision arthroplasty. Lazarinis S; Kärrholm J; Hailer NP Acta Orthop; 2012 Oct; 83(5):427-35. PubMed ID: 22937978 [TBL] [Abstract][Full Text] [Related]
5. Fixation of acetabular cups without cement in total hip arthroplasty. A comparison of three different implant surfaces at a minimum duration of follow-up of five years. Manley MT; Capello WN; D'Antonio JA; Edidin AA; Geesink RG J Bone Joint Surg Am; 1998 Aug; 80(8):1175-85. PubMed ID: 9730127 [TBL] [Abstract][Full Text] [Related]
6. Superior 11-year survival but higher polyethylene wear of hydroxyapatite-coated Mallory-Head cups. Gottliebsen M; Rahbek O; Ottosen PF; Søballe K; Stilling M Hip Int; 2012; 22(1):35-40. PubMed ID: 22383319 [TBL] [Abstract][Full Text] [Related]
7. The acetabular component in total hip arthroplasty. Evaluation of different fixation principles. Thanner J Acta Orthop Scand Suppl; 1999 Aug; 286():1-41. PubMed ID: 10572504 [TBL] [Abstract][Full Text] [Related]
8. [Long-term experience with the combined ARBOND hydroxyapatite coating in implant osteointegration]. Landor I; Vavrík P; Jahoda D; Pokorný D; Ballay R; Sosna A Acta Chir Orthop Traumatol Cech; 2009 Jun; 76(3):172-8. PubMed ID: 19595277 [TBL] [Abstract][Full Text] [Related]
9. Long-term results of the ABG-1 hydroxyapatite coated total hip arthroplasty: analysis of 111 cases with a minimum follow-up of 10 years. Bidar R; Kouyoumdjian P; Munini E; Asencio G Orthop Traumatol Surg Res; 2009 Dec; 95(8):579-87. PubMed ID: 19926546 [TBL] [Abstract][Full Text] [Related]
10. The performance of two hydroxyapatite-coated acetabular cups compared with Charnley cups. From the Norwegian Arthroplasty Register. Havelin LI; Espehaug B; Engesaeter LB J Bone Joint Surg Br; 2002 Aug; 84(6):839-45. PubMed ID: 12211674 [TBL] [Abstract][Full Text] [Related]
11. The Absence of Hydroxyapatite Coating on Cementless Acetabular Components Does Not Affect Long-Term Survivorship in Total Hip Arthroplasty. Sato T; Nakashima Y; Komiyama K; Yamamoto T; Motomura G; Iwamoto Y J Arthroplasty; 2016 Jun; 31(6):1228-1232. PubMed ID: 26730449 [TBL] [Abstract][Full Text] [Related]
12. Eight-year results of hydroxyapatite-coated hip arthroplasty. Chang JK; Chen CH; Huang KY; Wang GJ J Arthroplasty; 2006 Jun; 21(4):541-6. PubMed ID: 16781407 [TBL] [Abstract][Full Text] [Related]
13. Grit-blasted and hydroxyapatite-coated total hip arthroplasty: an 11- to 14-year follow-up study. Miyakawa S; Kawamura H; Mishima H; Yasumoto J J Orthop Sci; 2004; 9(5):462-7. PubMed ID: 15449121 [TBL] [Abstract][Full Text] [Related]
14. Ten- to twelve-year follow-up of the furlong hydroxyapatite-coated femoral stem and threaded acetabular cup in patients younger than 65 years. Gabbar OA; Rajan RA; Londhe S; Hyde ID J Arthroplasty; 2008 Apr; 23(3):413-7. PubMed ID: 18358381 [TBL] [Abstract][Full Text] [Related]
15. Increased risk of revision of acetabular cups coated with hydroxyapatite. Lazarinis S; Kärrholm J; Hailer NP Acta Orthop; 2010 Feb; 81(1):53-9. PubMed ID: 19968603 [TBL] [Abstract][Full Text] [Related]
16. Inferior survival of hydroxyapatite versus titanium-coated cups at 15 years. Stilling M; Rahbek O; Søballe K Clin Orthop Relat Res; 2009 Nov; 467(11):2872-9. PubMed ID: 19330391 [TBL] [Abstract][Full Text] [Related]
17. Cementless cups do not increase osteolysis risk in metal-on-metal total hip arthroplasty. Apropos of 106 cases. Beldame J; Carreras F; Oger P; Beaufils P Orthop Traumatol Surg Res; 2009 Nov; 95(7):478-90. PubMed ID: 19801209 [TBL] [Abstract][Full Text] [Related]
18. Early failure of smooth hydroxyapatite-coated press-fit acetabular cup--7 years of follow-up. Cheung KW; Yung SH; Wong KC; Chiu KH J Arthroplasty; 2005 Aug; 20(5):627-31. PubMed ID: 16309999 [TBL] [Abstract][Full Text] [Related]
19. Femoral revision surgery using a fully hydroxyapatite-coated stem: a cohort study of twenty two to twenty seven years. Reikerås O Int Orthop; 2017 Feb; 41(2):271-275. PubMed ID: 27131803 [TBL] [Abstract][Full Text] [Related]
20. Is alumina-on-alumina ceramic bearings total hip replacement the right choice in patients younger than 50 years of age? A 7- to 15-year follow-up study. Boyer P; Huten D; Loriaut P; Lestrat V; Jeanrot C; Massin P Orthop Traumatol Surg Res; 2010 Oct; 96(6):616-22. PubMed ID: 20620127 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]