These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
157 related articles for article (PubMed ID: 12194931)
1. Interlaboratory variation of plasma total homocysteine measurements: results of three successive homocysteine proficiency testing surveys. Hanson NQ; Eckfeldt JH; Schwichtenberg K; Aras O; Tsai MY Clin Chem; 2002 Sep; 48(9):1539-45. PubMed ID: 12194931 [TBL] [Abstract][Full Text] [Related]
2. Comparison of plasma total homocysteine measurements in 14 laboratories: an international study. Pfeiffer CM; Huff DL; Smith SJ; Miller DT; Gunter EW Clin Chem; 1999 Aug; 45(8 Pt 1):1261-8. PubMed ID: 10430793 [TBL] [Abstract][Full Text] [Related]
3. Analytical performance and method comparison study of the total homocysteine fluorescence polarization immunoassay (FPIA) on the AxSYM analyzer. Lonati S; Novembrino C; Ippolito S; Accinni R; Galli C; Troonen H; Campolo J; Della Noce C; Lunghi G; Catena FB Clin Chem Lab Med; 2004 Feb; 42(2):228-34. PubMed ID: 15061366 [TBL] [Abstract][Full Text] [Related]
4. Multicenter study of homocysteine measurement--performance characteristics of different methods, influence of standards on interlaboratory agreement of results. Tripodi A; Chantarangkul V; Lombardi R; Lecchi A; Mannucci PM; Cattaneo M Thromb Haemost; 2001 Feb; 85(2):291-5. PubMed ID: 11246550 [TBL] [Abstract][Full Text] [Related]
5. Comparison of three different plasma homocysteine assays with gas chromatography-mass spectrometry. Ubbink JB; Delport R; Riezler R; Vermaak WJ Clin Chem; 1999 May; 45(5):670-5. PubMed ID: 10222354 [TBL] [Abstract][Full Text] [Related]
6. Performance comparison of three assay methods used in fasting and postmethionine load plasma homocysteine determinations from patients with vascular disease. Mourvaki E; Ferrante F; Ghirarduzzi A; Brini M; Depunzio I; Iorio A Am J Clin Pathol; 2005 Nov; 124(5):675-81. PubMed ID: 16203288 [TBL] [Abstract][Full Text] [Related]
7. Measurement of total homocysteine in plasma and blood spots using liquid chromatography-tandem mass spectrometry: comparison with the plasma Abbott IMx method. McCann SJ; Gillingwater S; Keevil BG; Cooper DP; Morris MR Ann Clin Biochem; 2003 Mar; 40(Pt 2):161-5. PubMed ID: 12662404 [TBL] [Abstract][Full Text] [Related]
8. Determination of total homocysteine in plasma: comparison of the Abbott IMx immunoassay with high performance liquid chromatography. Zighetti ML; Chantarangkul V; Tripodi A; Mannucci PM; Cattaneo M Haematologica; 2002 Jan; 87(1):89-94. PubMed ID: 11801469 [TBL] [Abstract][Full Text] [Related]
9. Method for the determination of total homocysteine in plasma and urine by stable isotope dilution and electrospray tandem mass spectrometry. Magera MJ; Lacey JM; Casetta B; Rinaldo P Clin Chem; 1999 Sep; 45(9):1517-22. PubMed ID: 10471655 [TBL] [Abstract][Full Text] [Related]
10. [Comparison of plasma total homocysteine determinations in 9 French hospital laboratories by using 6 different methods]. Ducros V; Candito M; Caussé E; Couderc R; Demuth K; Diop ME; Drai J; Gerhardt MF; Quillard M; Read MH; Sauvant MP Ann Biol Clin (Paris); 2002; 60(4):421-8. PubMed ID: 12147446 [TBL] [Abstract][Full Text] [Related]
11. Evaluation of novel assays in clinical chemistry: quantification of plasma total homocysteine. Nexo E; Engbaek F; Ueland PM; Westby C; O'Gorman P; Johnston C; Kase BF; Guttormsen AB; Alfheim I; McPartlin J; Smith D; Møller J; Rasmussen K; Clarke R; Scott JM; Refsum H Clin Chem; 2000 Aug; 46(8 Pt 1):1150-6. PubMed ID: 10926896 [TBL] [Abstract][Full Text] [Related]
12. Assay methods for the measurement of total homocyst(e)ine in plasma. Ubbink JB Semin Thromb Hemost; 2000; 26(3):233-41. PubMed ID: 11011841 [TBL] [Abstract][Full Text] [Related]
13. Clinical validation of a new blood collection tube for the accuracy of total homocysteine measurement by different methods. Bissé E; Epting T; Kögel G; Obeid R; Gempel K; Huzly D; Fuhrmann K; Rolinski B; Herrmann W; Wieland H Clin Biochem; 2007 Jun; 40(9-10):739-43. PubMed ID: 17467680 [TBL] [Abstract][Full Text] [Related]
14. Comparing the ESA HPLC total homocysteine assay with electrochemical detection to the CDC in-house HPLC assay with fluorescence detection. Zhang M; Pfeiffer CM Clin Chim Acta; 2004 Feb; 340(1-2):195-200. PubMed ID: 14734212 [TBL] [Abstract][Full Text] [Related]
15. Comparison of three methods for total homocysteine plasma determination. Brunelli T; Pepe G; Marcucci R; Giusti B; Prisco D; Abbate R; Fedi S Clin Lab; 2001; 47(7-8):393-7. PubMed ID: 11499802 [TBL] [Abstract][Full Text] [Related]
16. High-throughput and simultaneous measurement of homocysteine and cysteine in human plasma and urine by liquid chromatography-electrospray tandem mass spectrometry. Rafii M; Elango R; Courtney-Martin G; House JD; Fisher L; Pencharz PB Anal Biochem; 2007 Dec; 371(1):71-81. PubMed ID: 17727809 [TBL] [Abstract][Full Text] [Related]
17. Comparison of the Abbott IMx and a high-performance liquid chromatography method for measuring total plasma homocysteine. Blanco-Vaca F; Arcelús R; González-Sastre F; Ordóñez-Llanos J; Queraltó-Compañó JM Clin Chem Lab Med; 2000 Apr; 38(4):327-9. PubMed ID: 10928653 [TBL] [Abstract][Full Text] [Related]
18. Simultaneous quantitation of homocysteine, cysteine and methionine in plasma and urine by liquid chromatography-tandem mass spectrometry. Weaving G; Rocks BF; Iversen SA; Titheradge MA Ann Clin Biochem; 2006 Nov; 43(Pt 6):474-80. PubMed ID: 17132278 [TBL] [Abstract][Full Text] [Related]
19. Rapid micro-scale assay for homocysteine by liquid chromatography-tandem mass spectrometry. Kuhn J; Götting C; Kleesiek K Clin Biochem; 2006 Feb; 39(2):164-6. PubMed ID: 16386724 [TBL] [Abstract][Full Text] [Related]
20. Evaluation of Advia Centaur automated chemiluminescence immunoassay for determining total homocysteine in plasma. Demuth K; Ducros V; Michelsohn S; Paul JL Clin Chim Acta; 2004 Nov; 349(1-2):113-20. PubMed ID: 15469863 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]