BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

208 related articles for article (PubMed ID: 12199580)

  • 1. Calibration standardization algorithm for partial least-squares regression: application to the determination of physiological levels of glucose by near-infrared spectroscopy.
    Zhang L; Small GW; Arnold MA
    Anal Chem; 2002 Aug; 74(16):4097-108. PubMed ID: 12199580
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Multivariate calibration standardization across instruments for the determination of glucose by Fourier transform near-infrared spectrometry.
    Zhang L; Small GW; Arnold MA
    Anal Chem; 2003 Nov; 75(21):5905-15. PubMed ID: 14588032
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Digital filtering and model updating methods for improving the robustness of near-infrared multivariate calibrations.
    Kramer KE; Small GW
    Appl Spectrosc; 2009 Feb; 63(2):246-55. PubMed ID: 19215656
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Spectral simulation methodology for calibration transfer of near-infrared spectra.
    Sulub Y; Small GW
    Appl Spectrosc; 2007 Apr; 61(4):406-13. PubMed ID: 17456259
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Wavelet analysis used for spectral background removal in the determination of glucose from near-infrared single-beam spectra.
    Wan B; Small GW
    Anal Chim Acta; 2010 Nov; 681(1-2):63-70. PubMed ID: 21035604
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Blank augmentation protocol for improving the robustness of multivariate calibrations.
    Kramer KE; Small GW
    Appl Spectrosc; 2007 May; 61(5):497-506. PubMed ID: 17555619
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Near-infrared spectroscopic measurement of glucose in a protein matrix.
    Marquardt LA; Arnold MA; Small GW
    Anal Chem; 1993 Nov; 65(22):3271-8. PubMed ID: 8291678
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Genetic algorithm-based method for selecting wavelengths and model size for use with partial least-squares regression: application to near-infrared spectroscopy.
    Bangalore AS; Shaffer RE; Small GW; Arnold MA
    Anal Chem; 1996 Dec; 68(23):4200-12. PubMed ID: 8946794
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Near-infrared spectroscopic measurement of physiological glucose levels in variable matrices of protein and triglycerides.
    Pan S; Chung H; Arnold MA; Small GW
    Anal Chem; 1996 Apr; 68(7):1124-35. PubMed ID: 8651489
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Determination of glucose in a biological matrix by multivariate analysis of multiple band-pass-filtered Fourier transform near-infrared interferograms.
    Mattu MJ; Small GW; Arnold MA
    Anal Chem; 1997 Nov; 69(22):4695-702. PubMed ID: 9375520
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Strategies for coupling digital filtering with partial least-squares regression: application to the determination of glucose in plasma by Fourier transform near-infrared spectroscopy.
    Small GW; Arnold MA; Marquardt LA
    Anal Chem; 1993 Nov; 65(22):3279-89. PubMed ID: 8291679
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Determination of glucose concentrations in an aqueous matrix from NIR spectra using optimal time-domain filtering and partial least-squares regression.
    Ham FM; Kostanic IN; Cohen GM; Gooch BR
    IEEE Trans Biomed Eng; 1997 Jun; 44(6):475-85. PubMed ID: 9151481
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Spectral simulation protocol for extending the lifetime of near-infrared multivariate calibrations.
    Sulub Y; Small GW
    Anal Chem; 2009 Feb; 81(3):1208-16. PubMed ID: 19132920
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Comparison of combination and first overtone spectral regions for near-infrared calibration models for glucose and other biomolecules in aqueous solutions.
    Chen J; Arnold MA; Small GW
    Anal Chem; 2004 Sep; 76(18):5405-13. PubMed ID: 15362899
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Determination of glucose concentration from near-infrared spectra using locally weighted partial least square regression.
    Malik B; Benaissa M
    Annu Int Conf IEEE Eng Med Biol Soc; 2012; 2012():6169-71. PubMed ID: 23367337
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Simultaneous measurement of glucose and glutamine in aqueous solutions by near infrared spectroscopy.
    Chung H; Arnold MA; Rhiel M; Murhammer DW
    Appl Biochem Biotechnol; 1995 Feb; 50(2):109-25. PubMed ID: 7717706
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Genetic algorithm-based protocol for coupling digital filtering and partial least-squares regression: application to the near-infrared analysis of glucose in biological matrices.
    Shaffer RE; Small GW; Arnold MA
    Anal Chem; 1996 Aug; 68(15):2663-75. PubMed ID: 8694264
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Comparison of performance of partial least squares regression, secured principal component regression, and modified secured principal component regression for determination of human serum albumin, gamma-globulin and glucose in buffer solutions and in vivo blood glucose quantification by near-infrared spectroscopy.
    Li BY; Kasemsumran S; Hu Y; Liang YZ; Ozaki Y
    Anal Bioanal Chem; 2007 Jan; 387(2):603-11. PubMed ID: 17171339
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Standardization of near infrared spectra measured on multi-instrument.
    Liu Y; Cai W; Shao X
    Anal Chim Acta; 2014 Jul; 836():18-23. PubMed ID: 24974866
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Scattering and absorption effects in the determination of glucose in whole blood by near-infrared spectroscopy.
    Amerov AK; Chen J; Small GW; Arnold MA
    Anal Chem; 2005 Jul; 77(14):4587-94. PubMed ID: 16013877
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 11.